TOYOTA SIENNA 2001 – VIDEO ENTERTAINMENT SYSTEM
Service Diagnostic Manual
Page 5 of 20 pages SM
Troubleshooting Table
Determine the failure condition, and then repair it by using the TROUBLESHOOTING TABLE.
The VES can communicate certain protection modes (which can resemble system failure) by
flashing the Status LED’s in the monitor assembly. These modes are defined on the next
page.
NOTE: Audio and video signals referred to in the troubleshooting table originate from the VCP
unless otherwise stated.
No. Condition Explanation Check and Repair
1No audio or video Protection Mode engaged
Trouble in IG Power sup-
ply
Remote Control NG
See Diagnostic Error Codes (Page 6).
STEP 1: CHECK 1 Radio/VCP fuse check.
STEP 2: CHECK 2 VES harness power connection check.
STEP 3: CHECK 3 VES harness ground check.
STEP 4: CHECK 4 VCP/Monitor Assembly harness check.
STEP 5: CHECK 5 Monitor Assembly ground distribution
check.
Check batteries and/or replace remote if required.
2No Audio
Video is OK
VCP accepts a
tape
Bad VHS Tape
Trouble in radio/VES set-
tings or connections
Try second VHS tape.
STEP 1: CHECK 6 FM Freq/FM Modulator check.
STEP 2: CHECK 7 VES/radio VOLUME check.
STEP 3: CHECK 8 FM Modulator harness check.
3No video Audio is
OK AUX mode engaged
Trouble in harness
Press VCP on remote.
STEP 1: CHECK 5 Monitor Assembly ground distribution
check.
4Radio will not tune
in stations Trouble with FM Modula-
tor STEP 1: Verify problem remains with VES OFF and screen
closed.
STEP 2: CHECK 8 FM Modulator harness check.
5VES audio too low
Radio volume OK VES VOL setting too low Raise volume with remote.
6AUX audio or video
NG VCP audio
and video OK
Trouble with AUX board in
center console STEP 1: CHECK 9 AUX board/Monitor Assembly check.
7No headphone
sound (wired) Problem in headphone,
AUX board, or harness STEP 1: Check headphone volume setting.
STEP 2: (OPTIONAL) Using test headphones, check for out-
put. IF NG, go to STEP 3.
STEP 3: CHECK 9 AUX/Monitor Assembly check.
8No headphone
sound (wireless) Problem in headphone,
AUX board, or harness STEP 1: Check headphone power switch and volume setting.
STEP 2: Check batteries in headphones.
STEP 3: (OPTIONAL) Test using test wired headphones. IF
NG, go to CHECK 9 AUX/Monitor Assembly check.
9Noise in VES audio
with Night–mode
on
Problem with FM Modula-
tor power filter Replace FM Modulator in–line power filter
(see diagram on Page 14).
10 VCP does not eject Problem in wiring or in
Monitor Assembly STEP 1: CHECK 10 Switched voltage check.
11 Audio poor – VCP
LED flashes VCP in Self–Tracking
mode, needs cleaning, or
bad videotape
VCP has auto tracking self–adjustment mode (indicated by
LED). If no flashing LED is present, clean with a good–quali-
ty head cleaner, and try another videotape with known good
audio.