TP-Link Omada DS1008X User manual

Installation Guide
10G Multi-Gigabit Desktop/Rackmount Switch
Power
© 2023 TP-Link 7106510574 REV1.0.0
Front Panel
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
Rear Panel
Grounding TerminalPower SocketKensington Security Slot
Feet
Bottom of the Device
Notch
Rack-mounting Bracket
Screw Rack
Method 1: Desktop Installation Method 2: Rack Installation
Appearance
10G
NAS/Server
Gaming
Computer
Workstation 2.5G
Wi-Fi 6 AP
8K Video
Router
LAN PortWAN Port
Internet
AC Power Cord Ethernet Ports (1-8)
Port LED
When one of the LED is on/ashing:
On: Connecting to a device but no activity.
Flashing: Transmitting or receiving data.
Left LED (10G/5G):
Green: Running at 10 Gbps.
Amber: Running at 5 Gbps.
Right LED (2.5G/1G/100M):
Green: Running at 2.5 Gbps.
Amber: Running at 100/1000 Mbps.
Power
On: Power on
O: Power o
Grounding Terminal
Kensington Security Slot
Power Socket
Secure the lock (not provided) into the security slot to prevent the device from being stolen.
The switch already comes with lightning protection mechanism. You can also ground the
switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable.
Plug the female connector of the power cord directly into the power socket and plug the
male connector into an AC outlet. Make sure that the voltage of the power supply meets
the requirement of the input voltage (100–240 V ~ 50/60 Hz).
Note: The images in this guide are for demonstration only and may dier from your actual product.
Installation
Connection
Note:
Leave 5 to 10 cm gaps around the devices for air circulation.
Avoid placing heavy things on the device.
Place the device with its bottom facing downwards.
Mount devices in sequence from the bottom to top of the rack and ensure a certain clearance
between devices for the purpose of heat dissipation.
LEDs
10 Gbps RJ45 Port
Transfer Method
Environmental and Physical Specications
FCC, CE, RoHS
0˚C to 50˚C (32˚F to 122˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90%RH non-condensing
5% to 90%RH non-condensing
Certication
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
General Specications
Specications
IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3an, IEEE 802.3bz
IEEE 802.3x, IEEE802.1p
CSMA/CD
8 100M/1G/2.5G/5G/10G RJ45 Ports
Auto-Negotiation/Auto MDI/MDIX
100BASE-TX:
2-pair UTP/STP of Cat. 5 or above (maximum 100 m)
1000BASE-T:
4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
2.5GBASE-T:
4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
5GBASE-T:
4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
10GBASE-T:
4-pair UTP of Cat 6 (maximum 55 m) or STP of Cat 6, 6a, 7 (maximum 100 m)
160 Gbps
Store-and-Forward
Automatically learning, automatically aging
100Base-TX: 148810 pps/port
1000Base-TX: 1488095 pps/port
2.5GBase-TX: 3720238 pps/port
5GBase-TX: 7440476 pps/port
10GBase-TX:14880952 pps/port
Standard
Network Media (Cable)
Interface
Switching Capacity
Protocol
To avoid any device damage and bodily injury caused by improper use, you should observe the following
rules.
Keep the power o during the installation.
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is
well grounded.
Use only the power cord provided with the switch.
Make sure that the supply voltage matches the specications indicated on the rear panel of the
switch.
Ensure that the switch is installed in a well-ventilated environment and its ventilation hole is not
blocked.
Do not open or remove the cover of the switch.
Before cleaning the device, cut o the power supply. Do not clean it by the waterish cloth, and never
use any other liquid cleaning method.
Place the device with its bottom surface downward.
Safety Precautions
Lightning Protection
Site Requirements
Temperature/Humidity
50°C
0°C
EnvironmentTemperature Humidity
Operating0 °C to 50 °C 10% to 90%RH Non-condensing
Storage-40 °C to 70 °C 5% to 90%RH Non-condensing
Installation Site
Extremely high voltage currents can be produced instantly when lightning occurs and the air in the
electric discharge path can be instantly heated up to 20,000 °C. As this instant current is strong enough
to damage electronic devices, more eective lightning protection measures should be taken.
Ensure that the rack and the device are well earthed.
Make sure the power socket has a good contact with the ground.
Keep a reasonable cabling system and avoid induced lightning.
Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note:
For detailed lightning protection measures, refer to the Lightning Protection Guide from the Related
Documents of our website: https://www.tp-link.com/us/conguration-guides/lightning_protection_guide.
When installing the device on a rack or a at workbench, attach much importance to the following items:
The rack or workbench is at, stable, and sturdy enough to support the weight of 5.5 kg at least.
The rack or workbench has a good ventilation system. The equipment room is well ventilated.
The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
Electronic elements including capacitance and inductance on the device can be aected by external
interferences, such as conducted emission by capacitance coupling, inductance coupling, and
impedance coupling. To decrease the interferences, make sure to take the following measures:
Use the power supply that can eectively lter interference from the power grid.
Keep the device far from high-frequency and strong-current devices such as radio transmitting
station.
Use electromagnetic shielding when necessary.
Electromagnetic Interference
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact of
metal contact points. Some measures have been taken for the device to prevent static electricity, but
too strong static electricity can cause deadly damage to the electronic elements on the internal circuit
board. To avoid the eect of static electricity on the operation of the switch, attach much importance to
the following items:
Dust the device regularly, and keep the indoor air clean.
Keep the device well grounded and ensure that the static electricity has been transferred.
Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little
humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion.
High temperatures may accelerate aging of the insulation materials, signicantly shortening the service
life of the device. To nd out the best temperature and humidity conditions for the device, check the
following table.
Clearness
Frame Forwarding Rate
MAC Address Learning
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of
directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of
the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
The original UK declaration of conformity may be found at https://www.tp-link.com/support/ukca/
UK declaration of conformity
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service,
please contact us.
Place the device with its bottom surface downward.
The plug on the power supply cord is used as the disconnect device, the
socket-outlet shall be easily accessible.
Plug the product into the wall outlets with earthing connection through the power
supply cord.
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents
or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.
CAUTION:
Double pole, neutral fusing.
Disconnect mainsbefore servicing.

Other TP-Link Switch manuals

TP-Link TL-SG1024DE User manual

TP-Link

TP-Link TL-SG1024DE User manual

TP-Link JetStream T2600G-18TS User manual

TP-Link

TP-Link JetStream T2600G-18TS User manual

TP-Link TL-SG1016DE User manual

TP-Link

TP-Link TL-SG1016DE User manual

TP-Link HS210 User manual

TP-Link

TP-Link HS210 User manual

TP-Link Omada SG3210X-M2 User manual

TP-Link

TP-Link Omada SG3210X-M2 User manual

TP-Link TL-SG108PE User manual

TP-Link

TP-Link TL-SG108PE User manual

TP-Link tapo S505D User manual

TP-Link

TP-Link tapo S505D User manual

TP-Link TL-SG1016DE User manual

TP-Link

TP-Link TL-SG1016DE User manual

TP-Link TL-SL2218 User manual

TP-Link

TP-Link TL-SL2218 User manual

TP-Link TL-SG2216 User manual

TP-Link

TP-Link TL-SG2216 User manual

TP-Link TL-SG2452 User manual

TP-Link

TP-Link TL-SG2452 User manual

TP-Link JetStream TL-SL5428E User manual

TP-Link

TP-Link JetStream TL-SL5428E User manual

TP-Link JetStream T1500G-8T User manual

TP-Link

TP-Link JetStream T1500G-8T User manual

TP-Link TL-SG2424P User manual

TP-Link

TP-Link TL-SG2424P User manual

TP-Link TL-SG2200 User manual

TP-Link

TP-Link TL-SG2200 User manual

TP-Link TL-SG3109 - Switch User manual

TP-Link

TP-Link TL-SG3109 - Switch User manual

TP-Link T3700G-28TQ User manual

TP-Link

TP-Link T3700G-28TQ User manual

TP-Link UC400 User manual

TP-Link

TP-Link UC400 User manual

TP-Link Omada RP108GE User manual

TP-Link

TP-Link Omada RP108GE User manual

TP-Link tapo 7106509958 User manual

TP-Link

TP-Link tapo 7106509958 User manual

TP-Link TL-SG105 User manual

TP-Link

TP-Link TL-SG105 User manual

TP-Link TL-SG3210 Instruction Manual

TP-Link

TP-Link TL-SG3210 Instruction Manual

TP-Link JetStream TL-SL5428E User manual

TP-Link

TP-Link JetStream TL-SL5428E User manual

TP-Link TL-SG116E User manual

TP-Link

TP-Link TL-SG116E User manual

Popular Switch manuals by other brands

NComputing RX-HDX Installation and configuration

NComputing

NComputing RX-HDX Installation and configuration

TRENDnet TU-700 Specifications

TRENDnet

TRENDnet TU-700 Specifications

Artel INFINITYLINK ILC205 Installation and operation guide

Artel

Artel INFINITYLINK ILC205 Installation and operation guide

LQ GROUP 1145616-00000 instruction manual

LQ GROUP

LQ GROUP 1145616-00000 instruction manual

US Robotics 7931 installation guide

US Robotics

US Robotics 7931 installation guide

HP A7340A - Surestore FC 1Gb/2Gb Switch 16B user guide

HP

HP A7340A - Surestore FC 1Gb/2Gb Switch 16B user guide

NETGEAR ProSafe FS752TP Hardware installation guide

NETGEAR

NETGEAR ProSafe FS752TP Hardware installation guide

Lowara SCUBA Series installation manual

Lowara

Lowara SCUBA Series installation manual

NetApp CN1610 Cli command reference

NetApp

NetApp CN1610 Cli command reference

CNET CSH-2400W user guide

CNET

CNET CSH-2400W user guide

Leitch Opus Master Control Product guide

Leitch

Leitch Opus Master Control Product guide

Open House H619 install guide

Open House

Open House H619 install guide

Linksys EG005W - Instant Gigabit Workgroup Switch user guide

Linksys

Linksys EG005W - Instant Gigabit Workgroup Switch user guide

ATEN CS-64U user manual

ATEN

ATEN CS-64U user manual

CTS HES-5106 Series user guide

CTS

CTS HES-5106 Series user guide

ADC FireWire Patch Panel IEEE 1394a Specification sheet

ADC

ADC FireWire Patch Panel IEEE 1394a Specification sheet

Jula 408-057 operating instructions

Jula

Jula 408-057 operating instructions

Tesla TSL-GW-GT01ZG quick start guide

Tesla

Tesla TSL-GW-GT01ZG quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.