V230516
Access Reader
125kHz / 13.56MHz
Copyright by SOYAL Technology Co., Ltd All rights reserved - 6 -
09. Communication Protocol Function Description
10. Extension Function
Table 9-1. Explanation of Communication Protocol Functions.
Dual Band (125kHz & 13.56MHz) 56~64 bites UID Tag
Table 9-2. 13.56MHz Chip ID Mapping
Table 9-3. Dual Band (125kHz & 13.56MHz) Tag Type Mapping
Echo Value Description
Head 7E Initial Value
Length 09 Compute the data length from Node to the end including XOR and SUM
Node Function 00 The value 00 is xed, the message would be sent to PC from the device
Data Field 71 Data receiving from AR-723-U
UID
04 Site H Site Code – High Site Hi Site Lo = 0x4D2
Site Code: 01234
D2 Site L Site Code – Low
DD Card H Card Code – High Card Hi Card Lo = 0xDDD5
Card Code: 56789
D5 Card L Card Code – Low
Type 01
- B (125kHz): CID [Bits(39~32)]
- D (13.56MHz): Chip ID (Please refer to Table 9-2)
- S (125kHz & 13.56MHz) : Tag Type (Please refer to Table 9-3)
XOR 51 XOR=FF^00^71^04^D2^DD^D5^01 =51
SUM 4B SUM=(00+71+04+D2+DD+D5+01+51)‧
FF=4B(LSB)
→ Send : 7E 09 00 71 [UID31-24] [UID23-16] [UID15-8] [UID7-0]
[Tag Type] [UID63-56] [UID55-48] [UID47-40] [UID39-32] XOR SUM
Chip Unknown Ultra Light Standard 1K Plus 4K SOR-LAM SOR-UIM SOR-CIM SOR-SIM
Code 0x00 0x01 0x02 0x03 0x22 0x42 0x42 0x82
Tags ISO14443A ISO14443B ISO15693 125kHz (EM)
Code 0x00 0x01 0x02 0x03
[i.e.] Card Number = 01234:56789
FAQ : How to setup the access mode as card plus pin on main controller and card only on
weigand reader?
FAQ : How to setup the door number of controller and reader in different configurations?
FAQ : Why I had set the new Wiegand Door Number,but it is still same to the Door Number?
FAQ : How to set up WG format of AR-661U?