Lock Settings
Set door unlock timer 40 Seconds: 1-999 # Set the amount of seconds the device will
grant access before locking again.
Set Access Code to toggle
[open/close]
41 # Entering Access Code will toggle the lock
to stay open. Entering the Access Code
again will toggle back to lock.
Set Access Code to toggle
[open/close] (partial
entry)
42 # Entering [The first 2 digits of an access
code, #] will toggle lock to remain open
and entering the full access code will
toggle back to close.
Safety Settings
Default safety setting 70 # After 10 successive false codes, the keypad
is disabled for 30 seconds
Extended safety settings 72 Number of false entries: 5-10 # After [5-10] successive false code entries,
the keypad is disabled for 15 minutes or
until the Master Code is entered.
Disable all safety settings 7600 #
Sound Settings
All sounds - On 831 # All sounds will be activated
All sounds - Off 830 # All sounds will be disabled
Access sound - 1 second
buzz
811 # Upon unlocking, the keypad will signal
granted access with a 1-second buzz
Access sound - 2 short
beeps
810 # Upon unlocking, the keypad will signal
granted access with 2 short beeps
Auto/Manual Code Entry Settings
Auto Code Entry Mode 821 # The # key after entering an access code
will NOT be required.
Important Note: For this feature to work
with Multi-User Mode, the Master Code
and Access Codes must be the same
number of digits. Ex. If the Master Code is
6-digits, then the Access Codes must also
be 6-digits to have the Auto Code Entry
Mode to work.
Manual Code Entry Mode 820 # The # key after entering an access code
will be required
Flashing Yellow LED Settings
Flashing Yellow LED - On 841 # The Yellow LED will blink every 2 seconds
during functionality
Flashing Yellow LED - Off 840 # The Yellow LED will not blink during
functionality
Access Lock (Optional)
Set Authorization Code
(Single User Mode)
2 4-digit code # Set 4-digit code for Access Lock activation.
Set Authorization Code
(Multi-User Mode)
2 User number: 0 to 9
4-8 digit code #
Set 4-8 digit code for Access Lock
activation.
Set Access Lock timer 50 Seconds: 1-999 # Set the amount of seconds Access Lock
will activate before deactivating
Set Authorization Code to
toggle [on/off]
51 # Entering Authorization Code will toggle
Access Lock on. Entering the Authorization
Code again will toggle Access Lock off.