Trotec BA30WP User manual

TRT-BA-BA30WP-TC2019-16-002-EN
BA30WP
EN
OPERATING MANUAL
HOT-WIRE ANEMOMETER
CONTROLLED VIA
SMARTPHONE

2 EN
hot-wire anemometer controlled via smartphone BA30WP
Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................5
Operation ...............................................................................5
Maintenance and repair ......................................................12
Errors and faults..................................................................13
Disposal ...............................................................................13
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
BA30WP
https://hub.trotec.com/?id=43337
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Do not immerse the device in water. Do not allow liquids to
penetrate into the device.
• The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.
• Protect the device from permanent direct sunlight.
• Do not expose the device to strong vibrations.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Do not open the device.
• Observe the storage and operating conditions as given in
the Technical data chapter.

EN 3
hot-wire anemometer controlled via smartphone BA30WP
Intended use
Use this device in combination with a terminal device that is
compatible with the installed Trotec MultiMeasure Mobile app.
Only use the device for measurements of air velocity, volumetric
flow, air temperature and relative humidity within the measuring
range specified in the technical data. Observe and comply with
the technical data.
The Trotec MultiMeasure Mobile app on the terminal device is
used for both operation and the evaluation of the measured
values.
Data logged by the device can be displayed, saved or
transmitted either numerically or in form of a chart.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.
Improper use
Do not use the device in potentially explosive atmospheres, for
measurements in liquids or on live parts.
Radio waves may interfere with the operation of medical
equipment and cause malfunctions. Do not use the device near
medical equipment or within medical institutions.
Persons with pacemakers must observe a minimum distance of
20cm between the pacemaker and the device.
Also do not use the device near automatically controlled
systems such as alarm systems and automatic doors. Radio
waves may interfere with the operation of such equipment and
cause malfunctions. Make sure that no other devices are
malfunctioning during the use of your device.
Any unauthorised changes, modifications or alterations to the
device are forbidden.
Personnel qualifications
People who use this device must:
• have read and understood the operating manual, especially
the Safety chapter.
Residual risks
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Note
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Note
Do not use abrasive cleaners or solvents to clean the
device.

4 EN
hot-wire anemometer controlled via smartphone BA30WP
Information about the device
Device description
Used in combination with Trotec's MultiMeasure Mobile app the
hot-wire anemometer permits measurements of air velocity,
volumetric flow, air temperature and relative humidity.
In case of individual measurements, the measurement value
display can be refreshed both via the app and by a brief
actuation of the measurement button at the measuring device.
Apart from the hold function, the measuring device can indicate
minimum, maximum and average values and carry out series
measurements.
In the app you can specify MAX and MINalarm thresholds for all
parameters measured with the device.
The measurement results can be displayed and saved on the
terminal device either numerically or in form of a chart. Then,
the measurement data can be sent in PDF or Excelformat.
The app also includes a report generation function, an organiser
function, one for customer management and further analysis
options. Moreover, it is possible to share measurements and
project data with colleagues in another subsidiary. If
MultiMeasure Studio Professional is installed on a PC, you can
even use report templates and ready-made text blocks for
various fields of application to turn the data into professional
reports.
Device depiction
BA30WP
1
2
34
5
No. Designation
1 Measuring sensor
2 LED
3On/ off/ measurement button
4 Battery compartment with cover
5 Lock
Technical data
Parameter Value
Model
Air flow rate
Measuring range 0m/s to 30m/s
0km/h to 108km/h
0ft/min to 5900ft/min
0mph to 67mph
0kn to 58kn
Accuracy ±(5%+ 0.1)m/s at <5m/s
±(5%+ 0.3)m/s at ≥5m/s
Resolution 0.01m/s
0.1km/h
1ft/min
0.1mph
0.1kn
Temperature
Measuring range -20°C to 60°C/ -4°F to 140°F
Accuracy ±0.8°C (at -20°C to 0°C/
-4°F to 32°F)
±0.5°C (at 0°C to 60°C/
32°F to 140°F)
Resolution 0.1°C/ 0.1°F
Humidity
Measuring range 0 to 99.9%RH
Accuracy ±3.5%RH (with 20 to 80%RH)
±5%RH (with 0 to 20%RH and
80 to 100%RH)
Resolution 0.1%RH
General technical data
Bluetooth standard Bluetooth4.0, Low Energy
Transmission power 3.16mW (5dBm)
Radio range approx. 10m
(depending on measuring environment)
Storage temperature -10°C to 60°C with <90%RH
non-condensing
Operating temperature -20°C to 50°C/ -4°F to 122°F
Power supply 3x 1.5V batteries, typeAAA
Device switch-off after approx. 3minutes without active
Bluetooth connection
Protection type IP40
Weight 122 g
Telescopic probe Length approx. 170mm to 375mm
Dimensions
(lengthx widthx
height)
22mmx 36mmx 320/555mm

EN 5
hot-wire anemometer controlled via smartphone BA30WP
Scope of delivery
• 1x Device BA30WP
• 3x 1.5V battery AAA
• 1 x Wrist strap
• 1 x Quick guide
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
When transporting the device, ensure dry conditions and and
protect the device from external influences e.g. by using a
suitable bag.
Storage
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• protected from dust and direct sunlight
• The storage temperature is the same as the range given in
the Technical data chapter.
• Remove the batteries from the device.
Operation
Inserting the batteries
Note
Make sure that the surface of the device is dry and the
device is switched off.
1. Unlock the battery compartment by turning the lock(5) in a
way that the arrow points towards the opened padlock
icon.
2. Remove the cover from the battery compartment(4).
3. Insert the batteries (3batteries of typeAAA) into the
battery compartment with correct polarity.
4. Put the cover back onto the battery compartment.
5. Lock the battery compartment by turning the lock(5) in a
way that the arrow points towards the closed padlock icon.
MultiMeasure Mobile app
Install the Trotec MultiMeasure Mobile app on the terminal
device you want to use in combination with the appSensor.
Info
Some of the app's functions require access to your
location and an active Internet connection.
The app is available for download in the Google Play Store as
well as in Apple's app store and via the following link:
https://hub.trotec.com/?id=43337

6 EN
hot-wire anemometer controlled via smartphone BA30WP
Start-up
Info
Allow for an acclimatization period of about 10minutes
in the respective measuring environment prior to the
appSensor's measuring operation.
Note
The measuring sensor consists of an extremely fine
wire and due to the design it is very fragile. Do not
touch the sensor. Protect the sensor from external
influences by attaching the protective cap during
non-use. Never use the measuring sensor as a lever or
to forcefully pierce through something. As a result the
measuring sensor could be severed from the housing.
Proceed as follows to start up the appSensor:
1. Adjust the telescopic probe to the desired length.
2. Move the appSensor's protective cover aside to reveal the
measuring sensor.
ðThe air circulates freely around the measuring sensor.
3. Hold the appSensor into the air current at a right angle.
This ensures a precise measurement.
I. II.
III.
Connecting the appSensor
Info
The app can simultaneously be connected to several
different appSensors or appSensors of the same type
and also record several measurements at the same
time.
Proceed as follows to connect the appSensor to the terminal
device:
üThe Trotec MultiMeasure Mobile app is installed.
üThe Bluetooth function on your terminal device is activated.
1. Start the Trotec MultiMeasure Mobile app on the terminal
device.
2. Briefly actuate the On/ off/ measurementbutton(3) three
times to switch on the appSensor.
ðThe LED(2) flashes yellow.
3. Press the SENSORS button(6) on the terminal device.
ðThe sensors overview opens.
4. Press the Refresh button(7).
ðIf the scanning mode was not active before, the colour
of the Refreshbutton(7) will change from grey to black.
The terminal device now scans the surroundings for all
available appSensors.
5. Press the Connect button(8) to connect the desired sensor
to the terminal device.
ðThe LED(2) flashes green.
ðThe appSensor is connected to the terminal device and
starts measuring.
ðThe on-screen display changes to the continuous
measurement.
Sensors
BC21WP
BA16WP
BM22WP
BM31WP
BP21WP
BA30WP
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Connect
Active sensors nearby
Available sensors
8
7
6
No. Designation Meaning
6SENSORS button Opens the sensors overview.
7Refresh button Refreshes the list of sensors near the
terminal device.
8Connect button Connects the displayed sensor to the
terminal device.

EN 7
hot-wire anemometer controlled via smartphone BA30WP
Continuous measurement
Info
Note that moving from a cold area to a warm area can
lead to condensation forming on the device's circuit
board. This physical and unavoidable effect can falsify
the measurement. In this case, the app will either
display incorrect measured values or none at all. Wait a
few minutes until the device has become adjusted to
the changed conditions before carrying out a
measurement.
When the appSensor has been successfully connected to the
terminal device, a continuous measurement is started and
indicated. The refresh rate is 1second. The 12most recently
measured values are displayed graphically(9) in chronological
sequence. The currently determined and calculated measured
values are displayed numerically(10).
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Temperatur
e
Relative humidity
[24,7 | 25,4] Ø 25
[37,6 | 58] Ø 40
25,3 °C
37,6 % RH
°C % RH
% RH
°C
9
10
25
26
27
28 40
35
11
Air velocity 0,43 m/s
Volumetric flow 0,0345 m³/min
m/s
[0,42 | 0,44] Ø 0,43
BA30WP
No. Designation Meaning
9Relative humidity
indication as
graphic display
Shows the measured relative humidity
over time.
Temperature
indication as
graphic display
Indicates the temperature as
measured over the course of time.
Volumetric flow
indication as
graphic display
Indicates the volumetric flow as
calculated over the course of time
(after having entered the area).
No. Designation Meaning
10 Tabular value
display
Temperature: Indicates minimum,
maximum and average value as well
as the current value.
Relative humidity: Indicates
minimum, maximum and average
value as well as the current value.
Air velocity: Indicates minimum,
maximum and average value as well
as the current value.
Enter area/ volumetric flow: Tap on
the field an enter the cross-sectional
area. Then the calculated value for the
volumetric flow will be displayed.
11 Menubutton Opens the menu to adjust the settings
of the current measurement.
Info
The indicated measured values will not be saved
automatically.
Info
By tapping on the graphic display(9) you can switch
over to the numeric display and vice versa.
Info
The volumetric flow can only be approximated, since
the flow type and speed of the air current is not
homogenous and thus identical across the entire
cross-section of the line/ pipe but varies from the
centre to the periphery! For a preferably precise
measurement move the sensor slowly and evenly in a
spiral motion from the centre to the edge and use the
determined average value as result.

8 EN
hot-wire anemometer controlled via smartphone BA30WP
Measurement settings
Proceed as follows to adjust the settings for the measurement:
1. Press the Menubutton(11).
ðThe context menu opens.
2. Adjust the settings as required.
12
13
14
15
16
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Reset min/ max/ Ø
X/Tmeasurement
Disconnect sensor
Sensor settings
Start recording
°C
°C
% RH
% RH
28
27
26
25
40
35
Temperature
Relative humidity
[24,7 | 25,4] Ø 25
[37,6 | 58] Ø 40 37,6 % RH
25,3 °C
m/s
BA30WP
No. Designation Meaning
12 Reset min/ max/ Ø
button
Deletes the determined values.
13 X/Tmeasurement
button
Switches between continuous
measurement and individual
measurement.
14 Disconnect sensor
button
Disconnects the connected
appSensor from the terminal device.
15 Sensor settings
button
Opens the settings menu for the
connected appSensor.
16 Start recording
button
Starts a recording of the determined
measured values for later evaluation.
Individual value measurement
Proceed as follows to select the individual value measurement
as measuring mode:
1. Press the Menubutton(11) to open the context menu for
sensors.
2. Press the X/Tmeasurement button(13) to switch from
continuous measurement to individual value measurement.
ðIndividual value measurement has been selected as
measuring mode.
ðReturn to the screen displaying the measured values.
ðThe first measured value is automatically determined
and displayed.
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Temperatur
e
Relative humidity
[24,7 | 25,4] Ø 25
[37,6 | 58] Ø 40
25,3 °C
37,6 % RH
18
19
17
Air velocity 0,43 m/s
Volumetric flow 0,0345 m³/min
[0,42 | 0,44] Ø 0,43
Refresh measured value
25,3 °C
37,6 % RH
0,43 m/s
BA30WP
No. Designation Meaning
17 Determined
individual value
indication
Indicates the individual values for
temperature, relative humidity and
volumetric flow determined at the
time of the measurement (see
Refreshing the measured value).
18 Tabular value
display
Temperature: Indicates minimum,
maximum and average value as well
as the current value.
Relative humidity: Indicates
minimum, maximum and average
value as well as the current value.
Air velocity: Indicates minimum,
maximum and average value as well
as the current value.
Enter area/ volumetric flow: Tap on
the field an enter the cross-sectional
area. Then the calculated value for the
current volumetric flow will be
displayed.
19 Refresh measured
value button
Performs an individual measurement
and refreshes the displays(17)
and(18).

EN 9
hot-wire anemometer controlled via smartphone BA30WP
Refreshing the measured value
Proceed as follows to refresh the measured values in the
individual value measurement mode:
1. Press the Refresh measured value button(19) on the
terminal device.
ðThe appSensor determines the current measured value
which is then displayed on the terminal device.
2. You can also press the On/ off/ measurement button(3)
on the appSensor.
ðThe appSensor determines the current measured value
which is then displayed on the terminal device.
Recording measured values
Proceed as follows to record measured values for later
evaluation:
1. Press the Menubutton(11).
ðThe context menu for sensors opens.
2. Press the Start recording button(16).
ðThe RECbutton(20) replaces the Menubutton(11).
3. If you perform a continuous measurement, the measured
values determined from then on will be recorded.
4. If you perform individual value measurements, repeatedly
press the On/ off/ measurement button(3) on the
appSensor or the Refresh measured value button(19) on
the terminal device until you have logged all the required
measured values.
20
21
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Reset min/ max/ Ø
X/Tmeasurement
Disconnect sensor
Sensor settings
°C
°C
% RH
% RH
28
27
26
25
40
35
Temperature
Relative humidity
[24,7 | 25,4] Ø 25
[37,6 | 58] Ø 40
37,6 % RH
25,3 °C
Stop recording
m/s
m/s
BA30WP
No. Designation Meaning
20 RECbutton Opens the sensor settings menu.
21 Stop recording
button
Stops the current recording of
measured values.
Opens the submenu for saving
recordings.
Stopping a recording
Proceed as follows to stop recording the measured values:
1. Press the RECbutton(20).
ðThe context menu for sensors opens.
2. Press the Stop recording button(21).
ðThe context menu for saving the recording opens.
3. You can optionally save, discard or resume the
measurement.
Saving a recording
Proceed as follows to save the recorded measured values:
1. Press the Savebutton(22) to save the recorded measured
values on the terminal device.
ðThe input mask for logging the recorded data opens.
2. Enter all the data relevant for an unambiguous assignment,
then save the recording.
ðThe recording will be saved on the terminal device.
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
°C
°C
% RH
% RH
28
27
26
25
40
35
Temperature
Relative humidity
[24,7 | 25,4] Ø 25
[37,6 | 58] Ø 40
37,6 % RH
25,3 °C
Save
Discard
Continue
22
24
23
m/s
m/s
Air velocity 0,43 m/s
[0,42 | 0,44] Ø 0,43
BA30WP
No. Designation Meaning
22 Savebutton Stops the current recording of
measured values.
Opens the input mask for logging
recording data.
23 Discardbutton Stops the current recording of
measured values.
Discards the recorded measured
values.
24 Continuebutton Resumes recording of the measured
values without saving.

10 EN
hot-wire anemometer controlled via smartphone BA30WP
Analysing measurements
Proceed as follows to call up the saved measurements:
1. Press the MEASUREMENTS button(25).
ðAn overview of already saved measurements will be
displayed.
2. Press the Display measurement button(27) for the desired
measurement to be indicated.
ðA context menu for the selected measurement opens.
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Measurements
03/26/2019
test_a1 (23)
25
27
26
28
No. Designation Meaning
25 MEASUREMENTS
button
Opens the overview of saved
measurements.
26 Indication of the
date of the
measurement
Indicates the date on which the
measurement was recorded.
27 Display
measurement
button
Opens the context menu for the
selected measurement.
28 Indication of the
number of
measured values
Indicates the number of individual
measured values constituting the
saved measurement.
The following functions can be called up in the context menu of
the selected measurement:
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
test_a1
Basic data
Evaluations
Evaluation parameters
Values
Generate table
Generate graphic
29
30
31
32
33
34
No. Designation Meaning
29 Basic data button Opens an overview of the data saved
for the measurement.
30 Evaluations button Opens an overview of the evaluations
generated for the measurement
(graphics and tables).
31 Evaluation
parameters button
Opens a menu to select and deselect
individual evaluation parameters.
32 Valuesbutton Opens a tabular overview of all the
values logged for the measurement.
33 Generate table
button
Creates a table containing the logged
values of the measurement and saves
it as a *.CSVfile.
34 Generate graphic
button
Creates a graphic representation of
the logged values and saves it as a
*.PNGfile.
Info
If you have saved a previous measurement with certain
parameters and then realize, that some parameters are
missing, you can subsequently edit them via the menu
item Evaluation parameters. They will not be added to
the already saved measurement, to be sure, but if you
save the measurement again with a different name,
these parameters will be added to the initial
measurement.

EN 11
hot-wire anemometer controlled via smartphone BA30WP
Generating a report
The reports generated in the MultiMeasure Mobile app are short
reports providing a fast and simple documentation. Proceed as
follows to generate a new report:
1. Press the REPORTS button(35).
ðThe reports overview opens.
2. Press the New report button(36) to create a new report.
ðAn input mask for entering all the relevant information
opens.
3. Enter the information via the input mask and save the data.
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Reports
Tap on "+" to generate a new
report.
35
36
No. Designation Meaning
35 REPORTS button Opens the overview of saved reports.
36 New report button Creates a new report and opens an
input mask.
Info
The customer can acknowledge the report directly in
the integrated signature field.
Calling up a report
Proceed as follows to call up a created report:
1. Press the REPORTS button(35).
ðThe reports overview opens.
2. Press the corresponding button(37) to display the desired
report.
ðAn input mask opens in which you can view and edit all
the information.
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Reports
03/26/2019
report 01
report 02
37
No. Designation Meaning
37 Display REPORT
button
Opens the selected report.

12 EN
hot-wire anemometer controlled via smartphone BA30WP
App settings
Proceed as follows to make settings in the Trotec MultiMeasure
Mobile app:
1. Press the SETTINGS button(41).
ðThe settings menu opens.
2. Adjust the settings as required.
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Settings
Language
German
Autom. Upload / Sync
WLAN
Account
Sign up
Log in
Div
UPDATE APP
Help
Sound
Support
41
appSensor settings
Proceed as follows to adjust the settings for the appSensor:
1. Press the SENSORS button(6).
ðA list of connected and available sensors will be
displayed.
2. Select the line with the appSensor the settings of which
you want do adjust and swipe right at the yellow marking.
3. Confirm your input.
ðThe sensor menu opens.
4. Alternatively, you can press the SENSORS button(6).
5. Press the Menubutton(11).
ðThe context menu opens.
6. Press the Sensor settings button(15).
ðThe sensor menu opens.
Disconnecting an appSensor
Proceed as follows to disconnect an appSensor from the
terminal device:
1. Press the SENSORS button(6).
ðA list of connected and available sensors will be
displayed.
2. Select the line with the appSensor to be disconnected and
swipe left at the red marking.
3. Confirm your input.
ðThe appSensor is now disconnected from the terminal
device and can be switched off.
4. Alternatively, you can press the Menubutton(11).
ðThe context menu opens.
5. Press the Disconnect sensor button(14).
6. Confirm your input.
ðThe appSensor is now disconnected from the terminal
device and can be switched off.
Switching off an appSensor
Info
Always terminate the connection between appSensor
and app before you switch off the appSensor.
Proceed as follows to switch off an appSensor:
1. Press and hold the On/ off/ measurement button(3) for
approx. 3seconds.
ðThe LED(2) on the appSensor goes out.
ðThe appSensor is switched off.
2. You may now exit the Trotec MultiMeasure Mobile app on
the terminal device.
Maintenance and repair
Battery change
A battery change is required when the LED at the appSensor
flashes red or the sensor can no longer be switched on. See
chapter Operation.
Cleaning
Clean the device with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive
cleaners, but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.

EN 13
hot-wire anemometer controlled via smartphone BA30WP
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Bluetooth connection is terminated or interrupted
• Check whether the LED at the appSensor flashes green.
If so, briefly switch it off completely, then turn it back on.
Establish a new connection to the terminal device.
• Check the battery voltage and insert new or freshly
charged batteries, if required.
• Does the distance between appSensor and terminal device
exceed the appSensor's radio range (see chapter Technical
data) or are there any solid building parts (walls, pillars
etc.) situated between appSensor and terminal device?
Shorten the distance between the two devices and ensure
a direct line of sight.
The sensor cannot be connected to the terminal device
although it is displayed there.
• Check the Bluetooth settings of your terminal device.
A possible reason for this could be special, manufacturer-
specific settings relating to an improved location accuracy.
Enable these settings, then try to establish a connection to
the sensor again.
Further information and assistance regarding the used sensor
type will be provided in the MultiMeasure Mobile app via the
menu item Settings=> Help. Selecting the menu item Help
opens a link to the app's help page. You can open a drop-down
menu with numerous support entries from the Table of
contents. Optionally, you can also scroll through the entire help
page and thoroughly acquaint yourself with the individual help
topics.
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
www.trotec.com
Other manuals for BA30WP
2
This manual suits for next models
1
Table of contents
Other Trotec Measuring Instrument manuals

Trotec
Trotec T510 User manual

Trotec
Trotec Bl20 User manual

Trotec
Trotec 3110008001 User manual

Trotec
Trotec BA30WP User manual

Trotec
Trotec T3000 User manual

Trotec
Trotec BD6A User manual

Trotec
Trotec BS06 User manual

Trotec
Trotec PD200 User manual

Trotec
Trotec SL800-SET User manual

Trotec
Trotec BV15WP User manual