  9. Rae ToxiRAE Pro PID User manual

Rae ToxiRAE Pro PID User manual

ToxiRAE Pro PID
QuickStart Guide
RAE Systems, Inc.
3775 N. First St.
San Jose, CA 95134-1708 USA
WARNINGS
Read Before Operating
The ToxiRAE Pro PID User’s Guide must be
carefully read by all individuals who have or will
have the responsibility of using, maintaining, or
servicing this product. The product will perform as
designed only if it is used, maintained, and serviced
in accordance with the manufacturer’s instructions.
CAUTION!
Never operate the monitor when the cover is
removed. Remove monitor top cap, rear cover, and
battery only in an area known to be non-hazardous.
User Interface
The ToxiRAE Pro PID’s user interface consists of
the display, four LED lights, an alarm buzzer, and
two keys, [MODE] and [Y/+]. The LCD displays
real-time reading in specifiedmeasurement units, sensor
type, alarm type (when in alarm, including cal. or bump
overdue), Man Down status, battery status, datalog (if on),
and radio and connection quality (if available).
Charging The ToxiRAE Pro PID
Always fully charge the battery before use. Contacts on
the bottom of the ToxiRAE Pro PID meet the cradle’s
contact pins, transferring power. While charging, the
LED on the cradle glows red. When the battery is fully
charged, the LED glows green.
Turning The ToxiRAE Pro PID On
Press and hold [MODE] for 3 seconds. During
startup, the battery, buzzer, vibration alarm, and
LEDs are tested, and then the ToxiRAE Pro PID
performs self-testing of its functions. When the
main measurement screen appears, the ToxiRAE
Pro PID is ready for calibration or use.
Note: If the battery is almost fully discharged, the
message “Battery too low! Needs charging.
Powering off!” shows in the display and the
ToxiRAE Pro PID shuts off. You must charge the
battery before you can use the instrument.
Turning The ToxiRAE Pro PID Off
Press and hold [MODE]. A 5-second countdown to
shutoff begins. You must continue pressing on the
key for the entire shutoff process. If you remove
your finger from the key during the countdown, the
shutoff operation is canceled and the ToxiRAE Pro
PID continues normal operation.
When the countdown beeps stop and you see “Unit
Off,” release your finger from the [MODE] key.
The ToxiRAE Pro PID is now off.
Belt clip (on back)
Alarm
Buzzer
LEDs
Display
[MODE] key
[Y/+] key
2.
3.
5.
6.
4.
Gas inlet
LED
Place ToxiRAE
Pro PID
in
cha
rging cradle
Connect AC
adapter to
charging
cradle and
plug it into AC
power source
Latch
release
Raised lip
locks into
cradle’s
latch
A
B
Charging
status LED
Phone: 408-952-8200 Fax: 408-952-8480
Email: customerserv@raesystems.com
www.raesystems.com
Calibration
The ToxiRAE Pro PID can be automatically bump tested
and calibrated using the AutoRAE 2 Test and Calibration
Station (refer to its User’s Guide for instructions).
Manually calibrate using a fixed-flow regulator (flow rate
between 0.5 and 1.0 liters per minute) and the supplied
special calibration adapter that covers the gas inlet:
1.To begin calibration, connect the zero air or
calibration gas cylinder, flow regulator, and calibration
adapter to the ToxiRAE Pro PID.
2.Enter Programming Mode by pressing and holding
[MODE] and [Y/+] simultaneously until the password
screen appears.
3.Input the 4-digit password. (The default password is
“0000.” If you do not know the password, highlight
and select “OK.”) Then follow the instructions for
zero calibration and span calibration.
Important! After a bump test or calibration, remove the
calibration adapter to ensure correct readings.
Zero (Fresh Air) Calibration
The ToxiRAE Pro PID should be zero-calibrated in
clean air with 20.9% oxygen. If the ambient air has
impurities, a cylinder of clean zero air should be used for
zero calibration. With the ToxiRAE Pro PID in
Programming Mode and “Zero Calib” highlighted:
1. Press [Y/+]. “Apply zero gas…” is displayed.
2. Start the flow of the zero gas, if used, and press
[Y/+] to start the fresh air or zero calibration.
3. The screen says, “Zeroing…” and shows the
countdown.
4. When done, it says, “Zero is done! Reading = 0.0
ppm” (this reading should be 0.0 ppm or very close
to it).
5. “Span Calib” is highlighted.
6. Shut off the flow of zero air (if used).
7. Remove the calibration adapter.
Manual Span Calibration
In Programming Mode, and with “Span Calib”highlighted:
1. Press [Y/+]. The screen displays the current (or
default) calibration gas and its concentration.
· Press [MODE] if you do not want to change it.
· Press [Y/+] if you do want to change it.
If youdid not change it, you will see a message likethis:
Cal. Gas:
Isobutylene
Span=100ppm
Apply gas…
2. Attach the calibration adapter, and connect the
calibration gas cylinder and flow regulator to the
ToxiRAE Pro PID, and start the gas flow.
3. Press [Y/+] to start calibration.
4. Upon completion, "Span is done!" and the reading
are shown. Make sure it is within ±10% of the span
gas value.
5. Remove the calibration adapter.
Bump (Functional) Testing
RAE Systems recommends periodic bump testing to
confirm that the sensor is working and that the alarms
are functional.
With the ToxiRAE Pro PID in Normal Mode:
1. Connect the calibration gas cylinder, flow
regulator, and calibration adapter to the
ToxiRAE Pro PID and start the gas flow.
2. Make sure the unit goes into alarm and that the
buzzer produces at least two beeps per second,
the LED lights flash on and off, and the vibration
alarm functions. The display backlight should
illuminate and an alarm message should be
shown in the display.
3. Turn off the gas flow.
4. Remove the calibration adapter.
8.
9.
10.
P/N: G02-4011-000 Rev C 201303
Menu Navigation In Normal Mode
Pressing [MODE] repeatedly
allows you to step through
the screens as shown here.
Note: The gray boxes
indicate the datalog
functions when datalogging
is in Manual mode. When
datalogging is in Automatic
mode, these screens do not
appear. Refer to the User’s
Guide for information on
selecting Automatic or
Manual datalogging.
11.
7.

Other Rae Measuring Instrument manuals

Rae GammaRAE II Responder User manual

Rae

Rae GammaRAE II Responder User manual

Rae microrae User manual

Rae

Rae microrae User manual

Rae ppbRAE 3000 User manual

Rae

Rae ppbRAE 3000 User manual

Rae QRAE II User manual

Rae

Rae QRAE II User manual

Rae MiniRAE 2000 PGM-7600 User manual

Rae

Rae MiniRAE 2000 PGM-7600 User manual

Rae AreaRAE Installation guide

Rae

Rae AreaRAE Installation guide

Rae DoseRAE 2 User manual

Rae

Rae DoseRAE 2 User manual

Rae AutoRAE Lite User manual

Rae

Rae AutoRAE Lite User manual

Rae GammaRAE II User manual

Rae

Rae GammaRAE II User manual

Rae DoseRAE 2 User manual

Rae

Rae DoseRAE 2 User manual

Rae UltraRAE 3000 Assembly instructions

Rae

Rae UltraRAE 3000 Assembly instructions

Rae MeshGuard User manual

Rae

Rae MeshGuard User manual

Rae ToxiRAE Pro User manual

Rae

Rae ToxiRAE Pro User manual

Rae MultiRAE Plus PGM-50/4 User manual

Rae

Rae MultiRAE Plus PGM-50/4 User manual

Rae MultiRAE Plus Guide

Rae

Rae MultiRAE Plus Guide

Rae MiniRAE Lite User manual

Rae

Rae MiniRAE Lite User manual

Rae UltraRAE 3000 User manual

Rae

Rae UltraRAE 3000 User manual

Rae TN-204 User manual

Rae

Rae TN-204 User manual

Rae MultiRAE User manual

Rae

Rae MultiRAE User manual

Rae VRAE PGM-7800 User manual

Rae

Rae VRAE PGM-7800 User manual

Rae ppbRAE 3000 User manual

Rae

Rae ppbRAE 3000 User manual

Rae QRAE 3 User manual

Rae

Rae QRAE 3 User manual

Rae NeutronRAE II User manual

Rae

Rae NeutronRAE II User manual

Rae microrae User manual

Rae

Rae microrae User manual

Popular Measuring Instrument manuals by other brands

WIKA 732.14.100 per ATEX operating instructions

WIKA

WIKA 732.14.100 per ATEX operating instructions

Endress+Hauser HART Proline t-mass I 300 operating instructions

Endress+Hauser

Endress+Hauser HART Proline t-mass I 300 operating instructions

Emerson Rosemount 8732 Quick installation guide

Emerson

Emerson Rosemount 8732 Quick installation guide

Omega HFH81 instruction sheet

Omega

Omega HFH81 instruction sheet

Brooks 1250-55 Series Installation and operation manual

Brooks

Brooks 1250-55 Series Installation and operation manual

Thermo Scientific Orion Star A216 reference guide

Thermo Scientific

Thermo Scientific Orion Star A216 reference guide

Rhopoint IQ operating instructions

Rhopoint

Rhopoint IQ operating instructions

Lutron Electronics PM-9112SD Operation manual

Lutron Electronics

Lutron Electronics PM-9112SD Operation manual

Spirent NOMAD UX Operation guide

Spirent

Spirent NOMAD UX Operation guide

Omron Z500 Series Product information

Omron

Omron Z500 Series Product information

DeFelsko PosiTector UTG quick guide

DeFelsko

DeFelsko PosiTector UTG quick guide

Agilent Technologies NFA Series Performance Verification and Calibration Guide

Agilent Technologies

Agilent Technologies NFA Series Performance Verification and Calibration Guide

sauter FK 10 instruction manual

sauter

sauter FK 10 instruction manual

Adam Equipment PMB instruction manual

Adam Equipment

Adam Equipment PMB instruction manual

Ebro SSX 210 manual

Ebro

Ebro SSX 210 manual

LP Technologies LPT-3000 user guide

LP Technologies

LP Technologies LPT-3000 user guide

Dewetron DEWE3-M4 Technical reference manual

Dewetron

Dewetron DEWE3-M4 Technical reference manual

Vanguard Instruments Company ATRT-03 user manual

Vanguard Instruments Company

Vanguard Instruments Company ATRT-03 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.