3. OPERATION
3. 1 Power ON/OFF
Switch on the scale by pressing . The display is switched on
and the self test is started.
If you want to switch off press the key again.
3. 2 ZERO
Environmental conditions can lead to the scale exactly zero in spite
of the pan not taking any strain. However, you can set the display of your
scale to zero any time by pressing key and therefore ensure that
the weighing starts at zero. The manual zero range is 2%Max.
3. 3 TARE
The weight of any container can be tared by pressing key so
that with subsequent weighing the net weight of the object being weighed
is always displayed.
Load weight on the pan.
Press key. Zero is displayed, and tare is subtracted.
Remove weight from the platform. Tared weight is displayed.
It can set only one tare value. It can display with a minus
value
Press key. Zero is displayed, tare weight is cleared.
The tare range is 2% >value ≤Max-1e
-2-
3. 4 Hold function
Press "Hold" before load at the pan, so HOLD is active now. "Hold
" and "-----" appeared at the display.
After put load at the pan no indication until a stable non-zero
weights is detected. During this period "----" is indicated. (no indication
of unstable value).You will hear a beep, when stable weight is detected.
Then it will show calculated HOLD-value with small "HOLD". After
unloading the pan the value will last for 10 Seconds, then it will come
back to normal weighing model.
Pressing “Hold”, while the HOLD-function is active, will cancel the
HOLD-function.
3. 5 BMI function
Press key in normal weighing mode, display will show the last
height “xxxxx”, use or key to shift twinkling digit, and press
or key to set the value, press key to confirm it, display
will enter into the BMI mode, “BMI”indicator will be shown, people stand
on the platform, display will show BMI value and the BMI bar graph.
Press key will turn back to normal weighing mode.
3. 6 Set Back light
Press and hold key at normal weighing model, display show
F1 off , press or key three times, display show F4 bk,
then press key to enter it: