TScale TR-I Series User manual

TR-I series
Wireless Crane Scale
User’s guide
UGTR-E1.02

TR-I serial wireless crane scale user’s manual
- I -
Table of Contents
SECTION 1 INTRODUCTION……………………………………………………………1
SECTION 2 SPECIFICATIONS……………………………………………………..……2
SECTION 3 INSTALLATION……………………………………………………………….3
SECTION 4 KEY DESCRIPTIONS………………………………………………………5
SECTION 5 DISPLAYS…………………………………………………………………….6
SECTION 6 OPERATION…………………….……………………………………….…..7
6.1 Zeroing the display………………………………………………………………….7
6.2 Taring……………………………………………………………………………..…….7
6.3 Weighing a sample…….………………………………………………….………….7
6.4 Accumulated total……………………………………………………………………….7
SECTION 7 PARAMETERS………………………………………………………………8
SECTION 8 BATTERY OPERATION………………………………………………..…10
SECTION 9 RS-232 OUTPUT…………………………………………………………..12
SECTION 10 CALIBRATION……………………………………………………..……..13
SECTION 11 ERROR CODE…………………………………………………………14
SECTION 12 TECHNICAL PARAMETES…………………………………………….15

TR-I serial wireless crane scale user’s manual
- 1 -
SECTION 1 INTRODUCTION
The TR-I series of wireless crane scale provides an accurate, fast and versatile
series of general purpose weighing scale with units conversion and division shift
functions.
All the keypads are sealed, color coded membrane switches and the displays are
large easy to read liquid crystal type displays (LCD). The LCD’s are supplied with a
backlight.
All units include automatic zero tracking, units conversion, audible alarm for pre-set
weights, and an accumulation facility that allows the individual weights to be stored
and recalled as an accumulated total.
The crane scale is firm and durable, and also it has several capacity could be
selected: 1t/2t/3t/5t/10t.

TR-I serial wireless crane scale user’s manual
- 2 -
SECTION 2 SPECIFICATIONS
Model
TR-I
Resolution
1/3,000
Capacity
1t/2t/3t/5t/10t
Interface
RS-232 Output Optional
Stabilisation Time
1 Seconds typical
Operating Temperature
0°C - 40°C / 32°F - 104°F
Power supply (external)
115 / 230 Vac, 120 / 240 Vac, 50/60Hz, 10 watts
Calibration
Automatic External
Display
6 digits 22mm LCD display, attached backlight
Housing
Indicator: ABS Plastic,
Crane scale: Stainless Steel
Zero range
0mV~5mV
Signal input range
0~15mV
ADC
Sigma delta
Internal counts
600,000
ADC update
Max 60 times /second
Load cell drive voltage
Max 5V/150mA
Load cells
Up to four 350 ohms cells

TR-I serial wireless crane scale user’s manual
- 3 -
SECTION 3 INSTALLATION
GENERAL INSTALLATION
The scales should be sited in a location that will not degrade the accuracy.
Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning
vents.
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not
place near vibrating machinery.
Avoid unstable power sources. Do not use near large users of electricity such as
welding equipment or large motors.
Avoid high humidity that might cause condensation. Avoid direct contact with water.
Do not spray or immerse the scales in water.
Avoid air movement such as from fans or opening doors. Do not place near open
windows.
Keep the indicator clean.
Do not stack material on the scales when they are not in use.
INSTALLATION OF TR SERIES
Please make the load cell connector from the load cell follow the drawing below
Attach the AC power adapter to the connector on the back of the indicator.
If you use TR for a platform scale, you can use attached indicator bracket, this
indicator bracket is design for 38mm pole.
Load cell connect as below( 5pin air connecter)
EXC+
SEN+
SEN-
EXC-
SIG+
SIG-
SHIELD
5
5
3
2
4
4
1
LOAD CELL

TR-I serial wireless crane scale user’s manual
- 4 -
SECTION 4 KEY DESCRIPTIONS
Zero
Set the zero point for all subsequent weighing. The display shows zero.(only when
the weight is less than 10% capacity)
Tare the scale. Stores the current weight in memory as a tare value, subtracts the
tare value from the weight and shows the results. This is the net weight. Entering a
value using the keypad will store that value as the tare value. (only when the weight
is large than 10% capacity)
A secondary function , of "Enter" key when setting parameters or other functions.
DIV
Change the division of the scale. This scale has two division (high and low) could be
selected,
A secondary function , of incrementing the active digit when setting a value for
parameters or other functions.
HOLD
reading lock key, use this key to lock reading, in calibrate mode, use this key to
change decimal point.
Secondary function , In the setting mode, this key used to move active digits
right.
M+
To print the results to a PC or printer using the optional RS-232 interface. It also
adds the value to the accumulation memory if the accumulation function is not
automatic.
Secondary function ( Cor ) , is to act as a clear key or to move active digits
left when setting values for parameters or other functions.
UNIT or U
Press this key to select the weight unit. Move the active digit left when setting values
for other functions.
Secondary function (ESC) , is to return to normal operation when the scale is in a
parameter setting mode.
ON/ OFF
Turn on or off the power.

TR-I serial wireless crane scale user’s manual
- 5 -
SECTION 5 DISPLAYS
The LCD display will show a value and a unit to the right of the digits.
In addition there are labels for TARE, GROSS weight, Zero and for Low battery
Battery low
Stable
Check weighing
Weighing unit
FROUNT
BACK

TR-I serial wireless crane scale user’s manual
- 6 -
SECTION 6 OPERATION
NOTE: In order to save energy of the battery to work for longer time, please turn off
the power switch in the crane scale only if you do not use the scale. When the battery
uses up, please charge it immediately.
Method: Open the crane scale, you will find a power switch beside the battery. Please
turn on/off it when you want/do not want to use the scale. When you want charge the
battery, please insert the adaptor into the charge hole on the crane scale.
6.1 Zeroing the Display
You can press the ZERO key at any time to set the zero point from which all other
weighing and counting is measured, within 10% of power up zero. This will usually
only be necessary when the platform is empty. When the zero point is obtained the
display will show the indicator for zero.
The scale has an automatic rezeroing function to account for minor drifting or
accumulation of material on the platform. However you may need to press the ZERO
key to rezero the scale if small amounts of weight are shown when the platform is
empty.
6.2 Taring
Zero the scale by pressing the ZERO key if necessary. The zero indicator will be on.
Place a container on the platform, a value for its weight will be displayed.
Press the ZERO key to tare the scale (only when the weight is large than 10%
capacity). The weight that was displayed is stored as the tare value and that value is
subtracted from the display, leaving zero on the display. The "TARE" indicator will be
on. As product is added only the weight of the product will be shown. The scale could
be tared a second time if another type of product was to be added to the first one.
Again only the weight that is added after taring will be displayed.
When the container is removed a negative value will be shown. If the scale was tared
just before removing the container this value is the gross weight of the container plus
all product that was removed. The zero indicator will also be on because the platform
is back to the same condition it was when the ZERO key was last pressed.
NOTE: When the weight is less than 10% capacity, this key function is zero, When
the weight is large than 10% capacity, this key function is tare.
6.3 Weighing a sample
To determine the weight of a sample first tare the empty container then place the

TR-I serial wireless crane scale user’s manual
- 7 -
sample in the container. the display will show the weight and the units of weight
currently in use.
6.4 Accumulated Total
6.4.1 Note
The scale can be set to accumulate manually by pressing the M+ key. See the
PARAMETERS Section for details of selecting the method using function "F5 P RT".
The accumulation function is only available when weighing.
Please note before every accumulate operate, scale need return to zero, and only
press M+ key when stable, when weight less than 20d, accumulate operate will be
invalid.
6.4.2 Accumulate operate
The weight displayed will be stored in memory when the M+ key is pressed and the
weight is stable.
The display will show "ACC 1" and then the total in memory for 2 seconds before
returning to normal. (after do accumulate operate, M+ indicator will turn on) If the
optional RS-232 interface is installed the weight will be output to a printer or PC.
Remove the weight, allowing the scale to return to zero and put a second weight on.
Press the M+ key, the display will show "ACC 2" and then the new total.
Continue until all weights have been added.
*Note: after you change weighing unit, accumulate value will be clear.
6.4.3 Memory recall
To view the totals in memory press M+ key in zero point (ZERO indicator on).
6.4.4 Memory clear
To clear the memory, just press UNIT key

TR-I serial wireless crane scale user’s manual
- 8 -
SECTION 7 PARAMETERS
The scale has 8 parameters that can be set by the user plus a method of entering the
calibration section.
Turn off the power if you are using the scale. then turn on the power, press the UNIT
key at the same time during self-checking.
Display shows “Pn---”, waiting for input password, Input password, HOLD key; UNIT
key and ZERO key. Then press the ZERO key to enter in.
The display will show the first function, "F0 div".
Pressing the DIV key will cycle through the other functions.
Pressing ZERO will allow you to set the function. It may be necessary to either use
DIV or set a value using the HOLD key to move the active digit and then using the
DIV key to increment a digit, followed by the ZERO key to enter the value. Use the
UNIT key to leave a parameter unchanged.
For example when the display shows “F0 DIV”, then press the DIV key to select “F1
az0”, press the ZERO key to begin.
The display will show “az 0.5d”, press the ZERO key to ensure, or press the DIV to
the next parameter. When you select a suitable value, press the ZERO key to
ensure.
After pressing the ZERO key to set a value, use the DIV key to continue to the next
parameter and set it as needed.
When all digits have been set press the ZERO key to store the value. The display
will go back to the parameter just set, Advance to another parameter if needed or
press the UNIT key to return to weighing.
FUNCTION MENU SETTINGS
Function
description
Defult
value
F0 div
Set the division
Low and High
Detail information as below
capacity
d (low division)
d (high division)
1000kg
2kg
1kg
0.5kg
0.5kg
0.2kg
0.1kg
2000kg
5kg
2kg
1kg
1kg
0.5kg
0.2kg
3000kg
10kg
5kg
2kg
2kg
1kg
0.5kg
5000kg
10kg
5kg
2kg
2kg
1kg
0.5kg
7500kg
20kg
10kg
5kg
5kg
2kg
1kg
10000kg
20kg
10kg
5kg
5kg
2kg
1kg
15000kg
50kg
20kg
10kg
10kg
5kg
2kg
Low

TR-I serial wireless crane scale user’s manual
- 9 -
F1 az0
Zero tracking
AZ 0.5d, AZ 1d
AZ 2d, AZ 4d
AZ 2d
F2 CAP
Capacity select
1000kg 2000kg
3000kg 5000kg
7500kg 10000kg
15000kg
5000kg
F3 bK
Set backlight
bK AU
bK on
bK oFF
BK
AU
F4 InP
Show internal count
F5 Unt
Select
kg on (turn on unit kg) oFF(turn off unit kg)
lb on (turn on unit lb) oFF(turn off unit lb)
tj on (turn on unit tj) oFF(turn off unit tj)
hj on (turn on unit hj) oFF(turn off unit hj)
F6 oFF
Auto turn off time
oFF 0 min turn on all the times
oFF 5 min turn off auto after 5 minutes
oFF 10 min turn off auto after 10 minutes
oFF 15 min turn off auto after 15 minutes
oFF 30 min turn off auto after 30 minutes
OFF 0
F7 Prt
Select print out format
Cont : continue send
(mostly use in computer communition)
LP-50: use LP-50 printer
AUTO
Prt 1 print out format 1
Prt 2 print out format 2
Prt 3 print out format 3
Prt 4 print out format 4
Prt 5 print out format 5
Auto
F8 CAL
calibration
UnLoadselect the calibration weightLoadcomplete
F9 bd
Baud value
Select 1200/2400/4800/9600
9600
F10 grv
Gravity value.
F11 lag
Language, select(English/Chinese)
English

TR-I serial wireless crane scale user’s manual
- 10 -
SECTION 8 BATTERY OPERATION
The weighing indicator can be operated from the battery if desired. The battery life is
approximately 35 hours.
When the battery needs charging a symbol on the weight display will turn on. The
battery should be charged when the symbol is on. The scale will still operate for
about 10 hours after which it will automatically switch off to protect the battery.
To charge the battery simply plug into the mains power. The scale does not need to
be turned on.
The battery should be charged for 12 hours for full capacity.
In the LCD display has a battery indicator to indicate the status of battery charging.
When the scale is plugged into the mains power the internal battery will be charged.
When turn on the indicator, if the battery indicator is full then the battery has a full
charge. If it is half then the battery is nearly discharged and empty indicates the
battery should be charged.
As the battery is used it may fail to hold a full charge. If the battery life becomes
unacceptable then contact your distributor.

TR-I serial wireless crane scale user’s manual
- 11 -
SECTION 9 RS-232 OUTPUT
The TR-I Series of scales can be ordered with an optional RS-232 output.
9.1 Basic information
Specifications:
RS-232 output of weighing data
ASCII code
8 data bits
No Parity
Baud rate: 1200bps
9. 2 print out format
Format 1
NO. 3
G.W. 20.50kg
N.W. 18.30kg
Format 2
NO. 3
N.W. 18.30kg
Format 3
NO. 3
G.W. 20.50kg
N.W. 18.30kg
Format 4
NO. 3
N.W. 18.30kg
Format 5
NO. 3
N.W. 18.30kg
TOTAL 60.40kg
9. 3 continuously output protocol
con1: weighing mode
,
,
-/+
k
g
CR
LF
-HEADER1-- - HEADER2- ---WEIGHT DATA --
HEADER1: ST=STABLE,US=UNSTABLE
HEADER2: NT=NET,GS=GROSS
-WEIGHT UNIT-
TERMINATOR

TR-I serial wireless crane scale user’s manual
- 12 -
SECTION 10 CALIBRATION
1) Turn off the power if you are using the scale.
2) Then turn on the power, press UNIT key at the same time during selfchecking.
3) Display shows “Pn---”, waiting for input password.
4) Input password, HOLD key; UNIT key and ZERO key. then press the ZERO key to
enter in.
5) Display will shows “F0 div”, press DIV key until display shows “F8 CaL”
6) Press ZERO key to enter calibrate, display shows “ULOAD”
7) Empty the hook, after STABLE indicator on, press ZERO key to sure, after some
seconds, zero calibrate completely.
8) After zero calibrate, display shows span calibrate mass weight, you can change
this weight, (use HOLD key to move the active digit, use DIV key to increment a
digit), after input calibrate mass weight, press ZERO key to sure, display show
“LOAD”, add calibrate mass on hook, after stable indicator on, press ZERO key
again, please wait some seconds, span calibrate completely.

TR-I serial wireless crane scale user’s manual
- 13 -
SECTION 11 ERROR CODES
ERROR
CODES
DESCRIPTION
RESOLUTION
- - ol -
Over range
Remove weight from the scale.
If the problem persist contact your dealer or
Taiwan scale for assistance.
Err 4
Zero Setting Error
The scale was outside the normal auto zero
setting range (4% of capacity), please check the
hook is empty, or calibrate zero point again.
Err 5
Keyboard Error
Keyboard short, please check the key wire or
whether the key have mechanical problem
Err 6
A/D out of range
The values from the A/D converter are outside the
normal range. Remove weight from the scale if
overloaded, make sure the pan is attached.
Indicates the load cell or the electronics may be
faulty.
If the problem persist contact your dealer or
Taiwan scale for assistance.
Err10
No single has been
received
Check if the distance is too long or the
environment is too bad.
Err11
The protocol is not
right or suitable
Update the new protocol.
Lo ba
Battery low
Charge battery immediately

TR-I serial wireless crane scale user’s manual
- 14 -
TAIWAN SCALE is a international supplier with more than 30 years experience in the
production and sale of electronic weighing equipment.
Products are supplied and serviced from our company locations in the CHINA,
TAIWAN and distributed through a world wide dealer network, also we make
OEM/ODM products for world wide customer.
TAIWAN SCALE's products are predominantly designed for the laboratory, medical,
business and industrial markets.
The product range can be summarised as follows:
Counting scales for general industrial and warehouse applications
Digital weighing/check-weighing scales
High performance platform scales with extensive software facilities including parts
counting, percent weighing etc.
Digital electronic scales for medical use
Retail price computing scales
Floor scales
Truck scale
Crane scales
Weighing indicator for platform scales, floor scales and truck scales
Hand push and pull gauge
Customize auto weighing systems
TAIWAN SCALE and their distributors offer a full range of technical services such as
on site and workshop repair, preventative maintenance and calibration facilities.
TAIWAN SCALE operates an approved quality management system and is certified
to ISO9001:2000.
Visit our Website at: www.taiwanscale.com
Taiwan Scale Mfg. Co., Ltd.
282, Sec.3, Hoping W. Rd.
Taipei,
Taiwan
TEL:886-2-23068203
FAX:886-2-23044354
W & P Scales Mfg. (Kunshan) Co., Ltd.
No. 99 Shunchang Road
Kunshan Hi-tech industry park
Kunshan, Jiangsu
China
TEL:86-512-57669080
FAX:86-512-57669100
e-mail: sales@taiwanscale.com
©Copyright by Taiwan Scale Mfg. Co., Ltd. All rights reserved. No part of this
publication may be reprinted or translated in any form or by any means without the
prior permission of Taiwan scale.
Taiwan Scale reserves the right to make changes to the technology, features,
specifications and design of the equipment without notice.
All information contained within this publication was to the best of our knowledge
timely, complete and accurate when issued. However, we are not responsible for
misimpressions which may result form the reading of this material.
The latest version of this publication can be found on our Website.
Table of contents
Other TScale Scale manuals

TScale
TScale JW User manual

TScale
TScale T-Touch P18 User manual

TScale
TScale NB Series User manual

TScale
TScale ROW Precision Balance Series User manual

TScale
TScale bw series User manual

TScale
TScale M 701 series User manual

TScale
TScale AW20 User manual

TScale
TScale s29 series User manual

TScale
TScale M301 User manual

TScale
TScale M503 Series User manual

TScale
TScale SP Series User manual

TScale
TScale JWP Installation manual

TScale
TScale IP30 User manual

TScale
TScale M503 Series User manual

TScale
TScale ATW series User manual

TScale
TScale QHW 15 User manual

TScale
TScale JC Series User manual

TScale
TScale ATP User manual

TScale
TScale TFB sereis User manual

TScale
TScale X7-11 User manual