12 THE CONTROL SYSTEM
CONTROL SYSTEM COMPONENT DESCRIPTIONS
24 VDC Power Supply (P/N 101206)
24 VDC Output at 40 Watts. Supplies control
voltage for I/O Control Board, 24 VDC Mechanical
Relays and Solid State Relays.
K1 Mechanical Relay (P/N 101271)
240 VAC, 30 Amp, Double Pole, Double Throw, 24
VDC Relay Coil. Switches power to the Magnetron
Filament Transformers.
K2 Mechanical Relay (P/N 101271)
240 VAC, 30 Amp, Double Pole, Double Throw, 24
VDC Relay Coil. Switches power to the Magnetron
High Voltage Transformers.
K3 Mechanical Relay (P/N 101271)
240 VAC, 30 Amp, Double Pole, Double Throw, 24
VDC Relay Coil. Safety Interlock device designed to
short L1 and L2 if the Monitor Switch opens before
the Primary and Secondary Interlock Switches.
K4/K5 SSR (P/N 101284)
240 VAC, Dual 40 Amp Solid State Relay. K4
(right) controls the Convection Heater and K5
(left) controls the IR Element.
K6 Mechanical Relay (P/N 101272)
240 VAC, 30 Amp, Three Pole, Double Throw, 24
VDC Relay Coil. Responsible for switching between
the 208VAC and 240VAC taps on the High
Voltage and Filament Transformers.
Interlock Switches (P/N 102012 for all three)
Primary, Secondary and Monitor Interlock Switches.
Switches must be actuated by the Cook Door in the
following order: M-S/P. When the Cook Door
opens, the order is reversed: P/S-M.
IR Thermocouple (IR Element)
Type K Thermocouple. Thermocouple is embedded
in the IR Element. The Thermocouple measures
the internal/sheath temperature of the IR Element.
Valid IR Set points are between 500ºF and 1200ºF.
The display indicates 1999ºF, if the Thermocouple
is “Open”.
EC Thermocouple (P/N 700-1179)
Type K Thermocouple. Thermocouple measures the
temperature of the Electrical Compartment. If the
temperature within the Electrical Compartment is
above 158ºF, the Control displays “F6 - EC Temp”.
CC Thermocouple (P/N NGC-1140)
Type K Thermocouple. Thermocouple measures
the temperature of the re-circulating impingement
airflow. Valid IR Set points are 450-540ºF. If the
display indicates 999ºF, the Thermocouple is Open.
BMSC (P/N 100443)
A proprietary Brushless DC Motor Controller
designed solely to operate the Convection Motor.
VDF Display (P/N 100505)
Vacuum Fluorescent Display.
Keypad (P/N NGC-1110)
3x8 Matrix Membrane Switch. Keypad is connected
to the Control via a 14 Pin Flat Cable.
Voltage Sense Module (P/N 100783)
Proprietary device designed to measure incoming
line voltage and switch between 208 and 240 VAC
operation. The device only measures and configures
the oven when the oven is switched from the Off
State to the On State.
TEST MODE
The Test Mode allows the service technician to
operate the oven’s subsystems individually. It also
allows the operator to configure various presets.
To enter the Test Mode:
1. Press the “Back” Key until the display is in the
Off State.
2. Press the “Back” and “Enter” Key simultaneously.
3. Enter the access code: 9-4-2-8 when prompted
and press “Enter”.
The “Test” Screen displays the Software Version,
Cook Chamber and IR Element Temperature at the
top of the screen. The Control also displays the