manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tylo
  6. •
  7. Plumbing Product
  8. •
  9. Tylo INFRA PANEL User manual

Tylo INFRA PANEL User manual

INFRA PANEL
980x680 / 980x360 / 980x280
Art.nr 2900 0265
2022-04-27
WARNING!
The heater must be connected by a qualified electrician pursuant to applicable regulations!
Always check that the heater is connected to the correct main/phase voltage!
Anyone with a mental or physical disability or little experience or knowledge of how to use the
equipment (e.g. children) must be instructed or supervised by someone responsible for their
safety.
Saunas are not recommended for people in poor health. Please consult a doctor.
Covering the heater may cause a fire.
The sauna room or cabin is to be inspected before either restarting the timer or by switching on
the appliance by a separate remote-control system
The sauna room or cabin is to be inspected before setting the appliance to a standby mode for
a delayed start
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved
Children shall not play with the appliance
Cleaning and user maintenance shall not be made by children without supervision
Do not add a locking or latching system to the door
Children must be supervised at all times in the sauna
Warning (Human limitations):
Prolonged exposure at elevated temperatures may cause hyperthermia (body temperature is
several degrees above 37°C (98.6F))
Hyperthermia symptoms include: dizziness, lethargy, drowsiness, and fainting
Hyperthermia can cause:
§Fetal damage in pregnant women
§Physical in-ability to exit the room
§Loss of consciousness
Notice - Use of alcohol or drugs increases the risk of fatal hyperthermia
If you have any health problems or health conditions, consult your physician prior to sauna use,
discontinue use if nervousness, tremor, headache, feeling of sickness or nausea occurs
Warning (Fire hazards):
Do not use the sauna room for drying cloths, bathing suits, etc.
Do not hang towels or other objects on heater grills
How to Use Combi Sauna:
Avoid eating large meals and excessive alcohol intake before using sauna.
Never smoke or drink alcohol or exercise inside of sauna.
If you are taking any medications or under the care of a physician, consult with them prior to
sauna usage.
Refer to sauna usage warning signs located inside of sauna room
980mm
980mm
680mm 360mm
300W
230V
150W
230V
37mm
Dimensions
Cable -
2 metre,
max. 200°C
Control panel
Elite
Sauna heater
Sense Elite
Product combinations for Infra
Infra Control panel
Elite
Relay box
Commercial Lite
Infra
Number of Infra panels - examples
Alternative 1 Alternative 2
Sauna heater Sense Elite - Max. 2.2 kW
Relay box Commercial Lite - Max 2.3 kW
300W 150W
x4 x4
+ = 1.8 kW
300W
x6
= 1.8 kW
300W 150W
x6 x2
+ = 2.1 kW
300W 150W
x4 x6
+ = 2.1 kW
1
3
2
4
Sauna heater
Sense Commercial/
Expression
(Max. 10.7 kW)
Control panel
Elite
Relay box
Commercial Lite
Infra
Alternative 3
980mm
280mm
100W
230V
Back wall
Side wall
Side wall
X X X X
Inside dimension (sauna room)
Outside dimension (sauna room flex size)
Example of placement of Infra panels in sauna room Harmony
Outside
dimensions (mm)
Flex size
Inside
dimensions
(mm)
Back wall - Infra panels
X (mm) Distance
between panels
980x680 (pcs)
980x360 (pcs)
1160
1018
-
2
99
1245
1103
1
1
21
1330
1188
-
3
27
1415
1273
-
3
48
1500
1358
-
3
69
1585
1443
2
-
27
1670
1528
2
-
56
1755
1613
2
-
84
1840
1698
-
4
51
1925
1783
-
4
68
2010
1868
2
1
37
2095
1953
2
1
58
2180
2038
2
1
79
2265
2123
3
-
21
2350
2208
3
-
42
2435
2293
3
-
63
2520
2378
3
-
84
2605
2463
2
2
76
2690
2548
2
2
93
Side wall - Infra panels
980x360 (pcs)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Under bench - Infra panels
980x280 (pcs)
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
Min.
300mm
Don’t place the infra panels over
or to close to the sauna heater!
Make sure that the outlet vent
does not end up behind the infra
panel. Preferably place the outlet
vent in the ceiling.
UP
UP
Open the Infra panel
Open the panel with a ”shake”
Measure and mark where the panels will be mounted
! Keep in mind that the front should fitNB
Push the front upwards
Min. 35mm
Ceiling
Wall
Infra panel
~ 650mm
UP
Ceiling
Wall Infra panel
Ceiling
Infra panel
Wall
Ø 10
~40mm
Ceiling
Infra panel
Wall
ALT. 1
ALT. 2
Drill holes through the wall/ceiling for the cables.
Pull the cables through the holes.
Mount the Infra
panels with
screws and put
the front back
1
2
x4
B6x16mm
x16
B8x22mm
x2 x2
Upper bracket
Lower bracket
Infra panel under the bench
Optional: Mounting kit for one infra panel
(Sold separately, art.no 9001 1307)
B6x16mm
X
X
X≈100mm
400mm
28mm
Placement of benches
(Benches - Classic/Classic Slim)
Mount the brackets on the back side of the infra panel
240mm
1/4"
x1
B8x22mm
B8x22mm
Mount the upper brackets on the upper bench
Mount the lower brackets on the lower bench
Tip how to fill eventual gaps
Example - two infra panels under the bench
BB
II
INFRA
Max. 2.2kW
10A
Sauna heater Elite
Connection
box
Infra Infra Infra Infra
...
BB
II
Sauna heater Elite
Glöm inte att jorda!
Do not forget to
ground (earth)!
Älä unohda maadoitusta!
Erdung nicht
vergessen!
Ne pas oublier de
mettre à la terre!
Connection diagram - Sauna heater Sense Elite and Infra panels
*
*
*
*
*
*
Combination: Sauna heater Sense Elite and Infra panels
*1.5mm
2
Infra
Light
Sauna heater Elite
Control Panel Sensor Door SwitchExternal Switch
12
6789
34 5
Distribution Box
Schematic diagram - Sauna heater Sense Elite
DIP switch settings
On
Off
CTS
123456
Sense Elite
System
Sauna IR
Pos. 6-9
G G
G G
Fuse 10A
IR + light
Sauna heater
Sense Elite
Combination: Relay box Commercial Lite and Infra panels
BB
RB Commercial Lite
I
1234
200-
240 V~
INFRA
Max. 2.3kW
10A
III G
BB
I
1234
200-
240 V~
III GConnection
box
RB Commercial Lite
Infra Infra Infra Infra
...
Connection diagram - Relay box Commercial Lite and Infra panels
Glöm inte att jorda!
Do not forget to
ground (earth)!
Älä unohda maadoitusta!
Erdung nicht
vergessen!
Ne pas oublier de
mettre à la terre!
*
*
*
*
*
*
*1.5mm
2
Control Panel
Heater 6-10 KW
Infra
Sensor Door Switch AUXExternal Switch
Light
Distribution Box
12
6789
34 5
RB Commercial Lite
Schematic diagram - Commercial LiteRB
DIP switch settings
On
Off
CTS
123456
RB Commercial Lite
System
Sauna IR
Pos. 6-9
User manual Infra - control panel Elite
How to enable operation.IR
1. Go to configure menu - IR
2. Press Enable
3. Go to settings – Now settings for
IR IR(Scale 0-10) are shown. are
ready to use.
IR
ON
OFF
0
0
4 min 20 sek
1
1 min 52 sek
2 min 28 sek
2
2 min 09 sek
2 min 11 sek
3
2 min 25 sek
1 min 55 sek
4
2 min 41 sek
1 min 39 sek
5
2 min 57 sek
1 min 23 sek
6
3 min 14 sek
1 min 06 sek
7
3 min 29 sek
0 min 51 sek
8
3 min 45 sek
0 min 35 sek
9
4 min 01 sek
0 min 19 sek
10
Continuous operation
Chart scale 0-10, operation timeIR
Function of .IR
Info!
WIRhen panel is heating then max 2 output (effect) in the sauna heater can be active at the
same time. This means that the sauna heater does not operate at full power, while the IR
heats. This is normal and nothing wrong. When the panel is in pause mode, full power isIR
allowed on the sauna heater, if required. This built-in monitoring occurs automatically in
systems.
IIRnfraheaters controlled by time ( scale 1-10) Sauna heater controlled by set temp.
TIRemperature range for allowed operation is only within setpoint temperature 40>60°C.
When temperature set to 40°C:
Sauna heater is completely shut off during ongoing bath, only heater according to setIR IR
scale 0>10 are in operation. Set scale are displayed together with set temperature on homeIR
screen.
When temperature set to 4 °C:1>60
IR IR IRheater according to set scale are in operation together with sauna heater. Set scale are
displayed together with set temperature on home screen.
When temperature set to °C:61>110
IR IRheater is completely shut off during ongoing bath, regardless of which scale is set. Only
sauna heater in operation. Set scale is not displayed on home screen, only setis IR
temperature is displayed.
When set to :IR 0
IR operation is completely shut off during ongoing bath, regardless of which temperature is set.
Only sauna heater according to set temperature is in operation.
When set :IR between 1>10
IR IRheater according to set scale are in operation provided that temperature is set between
40>60°C. operation is controlled by time, ac oording to Chart scale 0>10. Operation time.IR IRc
Info!
The set scale is displayed only on home screen when temperature is set between 40>60°C.IR
So when you see scale, you know that in operation and heating according to set scale.IR IR is
If Set scale not displayed, you know that is completely shut off.IR IRis
IR in Operation IR completely shut off
IR during Standby operation:
IR IRoperation is not allowed during standby operation. can only be used with bath.
During standby operation only sauna heater is preheated. Then when bath is started thru
control panel Elite or external switch, the heater will start. Note! only start if setIR IR
temperature is between 40>60°C and set scale is between 1>10.IR
Forced preheating:
FIRIRorced preheating in 20min of starts when operation is activated time duringfirst
ongoing bath. Forced preheating is dependent on R temp in room vs set temp. Forcedeal-
preheating is only allowed to start once during a bath.
FIRorced preheating of is never given when R -temp in room is the same as set temp oreal
higher during operation.
Interlock when to high temperature in room:
If the temperature in room reaches 68°C during ongoing bath when is in operation (setReal- IR
temperature between 40>60°C) then operation is paused automatically until temperatureIR
drops down to at least 67°C then starts again. This function works hidden in the system, no,IR
notice is displayed when the pause occur.

Other Tylo Plumbing Product manuals

Tylo Prime 1812 User manual

Tylo

Tylo Prime 1812 User manual

Tylo tx202/w User manual

Tylo

Tylo tx202/w User manual

Tylo Tylosand T-810 Operation manual

Tylo

Tylo Tylosand T-810 Operation manual

Tylo 1105-120 User manual

Tylo

Tylo 1105-120 User manual

Tylo Sauna i1115 Corner User manual

Tylo

Tylo Sauna i1115 Corner User manual

Tylo Sauna i1713 User manual

Tylo

Tylo Sauna i1713 User manual

Tylo Panacea 1717 User manual

Tylo

Tylo Panacea 1717 User manual

Tylo Round Vision 150 User manual

Tylo

Tylo Round Vision 150 User manual

Tylo Panacea 1309 t User manual

Tylo

Tylo Panacea 1309 t User manual

Tylo T825H User manual

Tylo

Tylo T825H User manual

Tylo Prime+ 1811 User manual

Tylo

Tylo Prime+ 1811 User manual

Tylo HARMONY User manual

Tylo

Tylo HARMONY User manual

Tylo Sauna i1313 User manual

Tylo

Tylo Sauna i1313 User manual

Tylo 1616 BASIC User manual

Tylo

Tylo 1616 BASIC User manual

Tylo Alu Line 150 User manual

Tylo

Tylo Alu Line 150 User manual

Tylo Alu Line 100 User manual

Tylo

Tylo Alu Line 100 User manual

Tylo 2900 2675 User manual

Tylo

Tylo 2900 2675 User manual

Tylo Prime 1313/C User manual

Tylo

Tylo Prime 1313/C User manual

Tylo Infra Kabin Prime 1815 User manual

Tylo

Tylo Infra Kabin Prime 1815 User manual

Tylo Prime 1211 User manual

Tylo

Tylo Prime 1211 User manual

Tylo FLEX SAUNA HARMONY GC User manual

Tylo

Tylo FLEX SAUNA HARMONY GC User manual

Tylo HARMONY GC ROUND User manual

Tylo

Tylo HARMONY GC ROUND User manual

Tylo Sauna i1309 User manual

Tylo

Tylo Sauna i1309 User manual

Tylo 2900 2665 User manual

Tylo

Tylo 2900 2665 User manual

Popular Plumbing Product manuals by other brands

Moen 7250C Series Installation guides

Moen

Moen 7250C Series Installation guides

EQUATION M400 instruction manual

EQUATION

EQUATION M400 instruction manual

KEUCO Edition 11 51171 015182 Instructions for use

KEUCO

KEUCO Edition 11 51171 015182 Instructions for use

noken CURVE 100237625-N199999002 manual

noken

noken CURVE 100237625-N199999002 manual

Balboa Water Group 500Z Series Operation guide

Balboa Water Group

Balboa Water Group 500Z Series Operation guide

Voda Plumbingware Olympia VOP91BG manual

Voda Plumbingware

Voda Plumbingware Olympia VOP91BG manual

Hans Grohe Ecos 31779007 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Ecos 31779007 Instructions for use/assembly instructions

Hewi AQ1.12S20040 Installation and operating instructions

Hewi

Hewi AQ1.12S20040 Installation and operating instructions

Hans Grohe Focus M41 200 1jet Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Focus M41 200 1jet Instructions for use/assembly instructions

Helvex Land EP-939 installation guide

Helvex

Helvex Land EP-939 installation guide

newform 69865E instructions

newform

newform 69865E instructions

KWC LUNA-E 10.441.023.700 Installation and service instructions

KWC

KWC LUNA-E 10.441.023.700 Installation and service instructions

Insignia KY2216 installation manual

Insignia

Insignia KY2216 installation manual

Triton AS2000X Installation and operating instructions

Triton

Triton AS2000X Installation and operating instructions

Saunacore CTY-WS16 instructions

Saunacore

Saunacore CTY-WS16 instructions

agape MEMORY AMEM871 Assembly instructions

agape

agape MEMORY AMEM871 Assembly instructions

Kraus KWT300-32 installation manual

Kraus

Kraus KWT300-32 installation manual

Dornbracht 35 230 970 90 installation instructions

Dornbracht

Dornbracht 35 230 970 90 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.