RIGHT ANGLE TORCH FOR USE IN HAZARDOUS LOCATIONS
ENGLISH ISSUED: 2015.06.01 V1
Description:
ATEX-RA2 is a portable, hand-held intrinsically safe flashlight for use in
hazardous locations and can be powered with four AA size alkaline
batteries. It has high and low mode operating functions that allows
users to operate for high brightness or long duration lighting.
Certifications:
Class I Div 1&2 Grp ABCD / Class II Div 1&2 Grp EFG
Class III / Temperature Code T4 IP54
File number: 261379
Gas: II 1G Ex ia IIC T4 Ga
Mine: I M1 Ex ia I Ma
Sira 15ATEX2166X
Gas: Ex ia IIC T4 Ga
Mine: Ex ia I Ma
IECEx SIR 15.0062X
0518
Accessories:
- Hand Strap
Warranty:
1 years Limited Warranty
Installation:
Operation:
Push the front button to operate. The sequence is high and
low mode.
Standards:
1. UL 913, 2011
2. UL783, 2011
3. CSA C22.2 No.157,
Reaffirmed 2012
4. EN 60079-0 : 2012/
A11:2013
5. EN 60079-11 : 2012
6. EN60079-26 : 2015
7. IEC 60079-0 : 2011
8. IEC 60079-11 : 2011
9. IEC 6007 9-26 : 2014
Battery Replacement:
Use only battery types below:
Alkaline type
Energizer E91
Duracell MN1500
Rayovac AL-AA
Varta 4906
Warning: Do not open in hazardous locations
Warning: To reduce the risk of explosion do not mix new
batteries with used batteries, or mix batteries from
different manufacturers or from different types.
Warning: Remove the batteries when unused for a period of
time to prevent battery leakage in the device.
Safety Warnings:
1. The screw shall be secured tightly after opening and closing
of the enclosure.
2. Substitution of components may impair intrinsic safety.
3. Clean the flashlight only with damp cloth to avoid static
electricity.
4. Do not flash the light beam directly to human’s eyes.
5. Always use the device following the regulations of eachwith
used batteries, or mix batteries from different country.
6. Where a static-generating mechanism is identified, such as
repeated brushing agains clothing, suitable precautions shall
be take, eg. the use of anti-static footwear.
SÉCURITÉ INTRINSÉQUE:
1. AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS
PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÉQUE
ATEX-
RA2
Unit 6, Colemeadow Road, North Moons Moat, Redditch, Worcestershire, UK, B98 9PB
Features:
»Intrinsically safe for use in
hazardous locations
»Angle head for use in chest
pocket
»High and Low mode
functions
»Uses high power CREE LED
»Submersible in water
»Tough and durable casing
»High efficient heatsink
»Screw fastener for safety
precautions
»Build-in gas release vent
Address: 1st FL, No.1, Alley 2, Lane 110, Sec.4, Hsimen Rd.
North District, Tainan, 704 Taiwan
Tel: +886(6) 2517782 / Email: DST@day-sun.com.tw
User Manual
HEADLAMP FOR USE IN HAZARDOUS LOCATIONS
English ISSUED: 2014.11.04 V1
Description: Installation:
DS-14 is a high power LED headlamp for use in hazardous locations
and is powered with three size AAA alkaline. It has high and
low mode operating functions that allows users to operate for high
brightness or long duration lighting.
Features:
- Intrinsically safe for use in hazardous locations
- High and Low mode functions
- Users high power CREE LED
- Focus and flood reflector
- Submersible in water
- Tough and durable casing
- Screw fastenerfor safety precautions Operation:
- Build-in gas release vent Push the top button to operate. The sequence is high and then low.
mode.
Certifications:
Class I Div 1&2 Grp ABCD / Class II Div 1&2 Grp EFG
Class III / Temperature Code T4 IP67
File number: E324236
II 1G Ex ia IIC T4 IP67
DEMKO 14 ATEX 1354X
Ex ia IIC T4 Ga IP67
IECEx UL 14.0059X
0539
Standards:
1. UL 913, Seventh Edition
2. CSA C22.2 No.157-92, Reaffirmed 2012
3. EN 60079-0 : 2009 Edition
4. EN 60079-11 : 2012 Edition Warranty:
5. EN 60079-26 : 2007 Edition 1 years Limited Warranty
6. IEC 60079-0 : Fifth Edition
7. IEC 60079-11 : Sixth Edition
8. IEC 60079-26 : Second Edition
Battery Replacement:
Use only battery types below:
Alkaline type
Energizer E92
Duracell MN2400
Panasonic AAA LR03(T)
Warning: Do not change batteries in hazardous locations.
Warning : To reduce the risk of explosion do not mix new batteries
with used batteries, or mix batteries from different
manufacturers or from different types.
Warning : Remove the batteries when unused for a period of time
to prevent battery leakage in the device. SÉCURITÉ INTRINSÉQUE:
1. AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS
Safety Warnings: PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÉQUE.
1. The screw shall be secured tightly after opening and closing of 2. AVERTISSEMENT : AFIN DE PRÉVENIR L’INFLAMMATION
the enclosure. D’ATMOSPHÉRES DANGEREUSES, NE CHANGER LES
2. Substitution of components may impair intrinsic safety. BATTERIES QUE DANS DES EMPLACEMENTS DÉSIGNÉS
3. Clean the headlamp only with damp cloth to avoid static NON DANGEREUX.
electricity.
4. Do not flash the light beam directly to human’s eyes.
5. Always use the device following the regulations of each
country.
ATEX-H2
Address: 1st FL, No.1, Alley 2, Lane 110, Sec.4, Hsimen Rd.
North District, Tainan, 704 Taiwan
Tel: +886(6) 2517782 / Email: DST@day-sun.com.tw
User Manual
HEADLAMP FOR USE IN HAZARDOUS LOCATIONS
English ISSUED: 2014.11.04 V1
Description: Installation:
DS-14 is a high power LED headlamp for use in hazardous locations
and is powered with three size AAA alkaline. It has high and
low mode operating functions that allows users to operate for high
brightness or long duration lighting.
Features:
- Intrinsically safe for use in hazardous locations
- High and Low mode functions
- Users high power CREE LED
- Focus and flood reflector
- Submersible in water
- Tough and durable casing
- Screw fastenerfor safety precautions Operation:
- Build-in gas release vent Push the top button to operate. The sequence is high and then low.
mode.
Certifications:
Class I Div 1&2 Grp ABCD / Class II Div 1&2 Grp EFG
Class III / Temperature Code T4 IP67
File number: E324236
II 1G Ex ia IIC T4 IP67
DEMKO 14 ATEX 1354X
Ex ia IIC T4 Ga IP67
IECEx UL 14.0059X
0539
Standards:
1. UL 913, Seventh Edition
2. CSA C22.2 No.157-92, Reaffirmed 2012
3. EN 60079-0 : 2009 Edition
4. EN 60079-11 : 2012 Edition Warranty:
5. EN 60079-26 : 2007 Edition 1 years Limited Warranty
6. IEC 60079-0 : Fifth Edition
7. IEC 60079-11 : Sixth Edition
8. IEC 60079-26 : Second Edition
Battery Replacement:
Use only battery types below:
Alkaline type
Energizer E92
Duracell MN2400
Panasonic AAA LR03(T)
Warning: Do not change batteries in hazardous locations.
Warning : To reduce the risk of explosion do not mix new batteries
with used batteries, or mix batteries from different
manufacturers or from different types.
Warning : Remove the batteries when unused for a period of time
to prevent battery leakage in the device. SÉCURITÉ INTRINSÉQUE:
1. AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS
Safety Warnings: PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÉQUE.
1. The screw shall be secured tightly after opening and closing of 2. AVERTISSEMENT : AFIN DE PRÉVENIR L’INFLAMMATION
the enclosure. D’ATMOSPHÉRES DANGEREUSES, NE CHANGER LES
2. Substitution of components may impair intrinsic safety. BATTERIES QUE DANS DES EMPLACEMENTS DÉSIGNÉS
3. Clean the headlamp only with damp cloth to avoid static NON DANGEREUX.
electricity.
4. Do not flash the light beam directly to human’s eyes.
5. Always use the device following the regulations of each
country.
ATEX-H2
Address: 1st FL, No.1, Alley 2, Lane 110, Sec.4, Hsimen Rd.
North District, Tainan, 704 Taiwan
Tel: +886(6) 2517782 / Email: DST@day-sun.com.tw
User Manual
HEADLAMP FOR USE IN HAZARDOUS LOCATIONS
English ISSUED: 2014.11.04 V1
Description: Installation:
DS-14 is a high power LED headlamp for use in hazardous locations
and is powered with three size AAA alkaline. It has high and
low mode operating functions that allows users to operate for high
brightness or long duration lighting.
Features:
- Intrinsically safe for use in hazardous locations
- High and Low mode functions
- Users high power CREE LED
- Focus and flood reflector
- Submersible in water
- Tough and durable casing
- Screw fastenerfor safety precautions Operation:
- Build-in gas release vent Push the top button to operate. The sequence is high and then low.
mode.
Certifications:
Class I Div 1&2 Grp ABCD / Class II Div 1&2 Grp EFG
Class III / Temperature Code T4 IP67
File number: E324236
II 1G Ex ia IIC T4 IP67
DEMKO 14 ATEX 1354X
Ex ia IIC T4 Ga IP67
IECEx UL 14.0059X
0539
Standards:
1. UL 913, Seventh Edition
2. CSA C22.2 No.157-92, Reaffirmed 2012
3. EN 60079-0 : 2009 Edition
4. EN 60079-11 : 2012 Edition Warranty:
5. EN 60079-26 : 2007 Edition 1 years Limited Warranty
6. IEC 60079-0 : Fifth Edition
7. IEC 60079-11 : Sixth Edition
8. IEC 60079-26 : Second Edition
Battery Replacement:
Use only battery types below:
Alkaline type
Energizer E92
Duracell MN2400
Panasonic AAA LR03(T)
Warning: Do not change batteries in hazardous locations.
Warning : To reduce the risk of explosion do not mix new batteries
with used batteries, or mix batteries from different
manufacturers or from different types.
Warning : Remove the batteries when unused for a period of time
to prevent battery leakage in the device. SÉCURITÉ INTRINSÉQUE:
1. AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS
Safety Warnings: PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÉQUE.
1. The screw shall be secured tightly after opening and closing of 2. AVERTISSEMENT : AFIN DE PRÉVENIR L’INFLAMMATION
the enclosure. D’ATMOSPHÉRES DANGEREUSES, NE CHANGER LES
2. Substitution of components may impair intrinsic safety. BATTERIES QUE DANS DES EMPLACEMENTS DÉSIGNÉS
3. Clean the headlamp only with damp cloth to avoid static NON DANGEREUX.
electricity.
4. Do not flash the light beam directly to human’s eyes.
5. Always use the device following the regulations of each
country.
ATEX-H2
BUTTON