Unit UT131B User manual

UT131A/B/C/D
I.Overview
I.I Open Box Inspection
I.Safe Operation RuleII
IV. Electrical Symbols
Warning
VI.Structure (see Figure 1)
Figure 1
Capacitance
Red Black Red Black
Figure 2bFigure 2a
Red Black
Figure 3
Figure 4
Red Black
Palm Size Multimeter
User Manual
The new generation UT131 series products redefine the performance
standards for entry-level digital multimeter. The innovative industrial design
ensures the products have 2 meters impact resistance. The new LCD display
layout provides a clear display for better user experience. The UT131 series
ensure safe operation in CAT II 250 V environment.
The special features of each model are as follows:
UT131A: 2mF capacitance test function
UT131B: Battery test with status indicators
UT131C: Temperature test
UT131D: NCV test
Open the package box and take out the device. Please check whether the
following items are deficient or damaged and contact your supplier immediately
if they are.
User manual ----------------------- 1 pcs
Test leads ---------------------------1 pair
Protective case---------------------1 pcs
K-type thermocouple -------------1 pcs (UT131 only)
Warning:
Please carefully read “Safe Operation Rule” before using the device.
1). Safety certification
This device strictly follows the CE standards: EN 61010-1: 2010,
EN 61010-2-030:2010, EN 61326:2013, as well as CAT II: 250V, RoHS,
pollution grade II, and double insulation standards.
2). Safety instructions and precautions
1. Do not use the device if the device or test leads appear damaged or if
you suspect that the device is not operating properly. Pay particular
attention to the insulation layers.
2 If the test leads are damaged, it must be replaced with one of the same .
type or the same electrical specification.
3 When measuring, do not touch exposed wires, connectors, unused inputs, .
or the circuit being measured.
4 When measuring the voltage higher than 60 VDC or 30 VACrms, keep .
your fingers behind the finger guard on the test lead in order to prevent
electric shock.
5 If the range of the voltage to be measured is unknown, the maximum range .
should be selected and then gradually decreased.
6 Never input voltage and current exceeding the value listed on the device..
7 Before switching ranges, make sure to disconnect the test leads with the .
circuit to be tested. It is strictly prohibited to switch the ranges during the
measurement.
8 Do not use or store the device in high temperature, high humidity, flammable, .
explosive or strong magnetic field environments.
9 Do not change the internal circuit of the device in order to avoid the damage .
to the device and users.
10.To avoid false reading, replace the battery when the battery indicator
appears.
11.Use dry cloth to clean the case, do not use detergent containing solvents
Low battery High voltage warning
Electrical ground
Double insulation
V. Specification
1. The maximum voltage between the input terminal and the ground:
250Vrms
2 10A terminal: Fuse 10A 250V Fast fuse Φ5×20mm.
3 mA/μA terminal: Fuse 200mA 250V Fast fuse Φ5×20mm.
4. Max display 1999, over range display “OL”, update rate: 2~3 times/second
5. Range select: Auto range UT131A; Manual range UT131B/C/D
6. Backlight: manual on, auto shut off after 30 seconds
7. Polarity: "-" symbol displaying on screen represents negative polarity
signal.
8. Data hold function: symbol displays on screen when data hold function
is activated
9. Low battery power: symbol displays on screen when battery power is low
10. Battery: AAA 1.5V * 2
11. Operating temperature: 0~40˚C (32˚F~104˚F)
Storage temperature: -10~50˚C (14˚F~122˚F)
Relative humidity: 0˚C~30˚C: ≤75% RH, 30˚C~40˚C: ≤50% RH
Operating altitude: 0 ~ 2000m
12. Dimension: (134×77×47) mm
13. Weight: about 206g (battery included)
14. Electromagnetic compatibility:
In fields with less than 1V/m radio frequency, the total accuracy
= designated accuracy + 5% of measurement range
In fields with more than 1V/m radio frequency, the accuracy is not
specified.
Display screen
Function keys
Functional dial
10A input jack
COM jack
Remaining inputs jack
1) UT131A:
SEL/REL: pre s s t his key to switch between AC and DC modes for
mV , I , and REL positions.
: Press to enter or exit data hold mode. Long press over 2 seconds HOLD/
to turn on/off backlight.
2) UT131B/C/D:
HOLD/SEL: Press to enter or exit data hold mode
In continuity/diode mode, press to cycle switch between the two modes
: Press to turn on/off backlight.
VI . OperationsII
VII. Key Functions
To avoid false reading, replace the battery if the battery low power symbol
appears. Also pay special attention to the warning sign beside the test
lead jack, indicating that the tested voltage or current must not exceed the
values listed on the device.
1.AC/DC voltage measurement (see Figure 2b)
1) Switch the dial to “V~” position.
2) Insert the black test lead into the COM jack, the red test lead into the
“VΩmA” jack. Connect test leads with the load in parallel.
Notes:
Do not measure voltage over 250V rms, or it may expose users to electric
shock and damage the device. If the range of the voltage to be measured is
unknown, select the maximum range and reduce accordingly.
Please pay extra attention when measuring high voltage in order to avoid
electric shock.
Before using the device, it is suggested to measure a known voltage for
verification.
2.Resistance measurement (see Figure 2b)
1) Switch the dial to “Ω” position.
2) Insert the black test lead into the COM jack, the red test lead into the “VΩmA”
jack. Connect test leads with the resistor in parallel
Notes:
Before measuring resistance, switch off the power supply of the circuit, and
fully discharge all capacitors.
If the resistance when probes are shorted is more than 0.5Ω, please check
are loosened or damaged.if test leads
If the resistor is open or over the range, the “OL” symbol will be displayed on
the screen.
When measuring low resistance, the test leads will produce 0.1Ω~0.2Ω
measurement error. To obtain accurate measurement, the measured value
should subtract the value displayed when two test leads are shorted.
When measuring high resistance above 1MΩ, it is normal to take a few
seconds to steady the readings. In order to quickly obtain steady data, use
short test wires to measure high resistance.
3. Continuity measurement (see Figure 2b)
1) Switch the dial to “ ” position.
2) Insert the black test lead into the COM jack, the red test lead into the “VΩmA”
jack. Connect test leads with the points to be tested in parallel
3) If measured points’ resistance >51Ω, circuit is in open status.
easured points’ resistance ≤10Ω, circuit is in good conduction status, If m
buzzer will go off
Notes:
Before measuring continuity, switch off all power supplies and fully discharge
all capacitors.
4. Diode measurement (see Figure 2b)
1) Switch the dial to “ ” position.
2) Insert the black test lead into the COM jack, the red test lead into the “VΩmA”
jack. Connect test leads with the diode in parallel
3) “OL” symbol appears when the diode is open or polarity is reversed.
For silicon PN junction, normal value: 500 ~ 800mV (0.5 ~ 0.8V).
Notes:
Before measuring PN junction, switch off the power supply to the circuit,
and fully discharge all capacitors
5. Capacitance measurement (only for UT131A, see Figure 2a)
1) Switch the dial to capacitance test.
2) Insert the black test lead into the COM jack, the red test lead into the
“VΩmA” jack. Connect test leads with the capacitor in parallel
3) When there is no input, the device displays a fixed value (intrinsic capacitance).
For small capacitance measurement, to ensure measurement
accuracy, the measured value must be subtracted from intrinsic capacitance.
Users can measure small capacity capacitors with relative measurement
functions (REL) (the device will automatically subtract the intrinsic
capacitance)
Notes:
If the tested capacitor is shorted or its capacity is over the specified range
“OL” symbol will be displayed on the screen.
When measuring large capacitors, it may take a few seconds to obtain
steady readings.
Before measuring capacitors (especially for high voltage capacitors), please
fully discharge them.
6. DC measurement (see Figure 3)
1) Switch the dial to DC test.
2) Insert the black test lead into the COM jack, the red test lead into the
“VΩmA” jack. Connect test leads with the tested circuit in series.
Notes:
Before measuring, switch off the power supply of the circuit and carefully
check the input terminal and range position.
If the range of the measured current is unknown, select the maximum
range and then accordingly. reduce
Please replace the fuse with the same type.
10A jack: Fuse 10A/250V Φ5×20mm
VΩmA jack: Fuse 0.2A/250V Φ5×20mm
When measuring, please do not connect the test leads with any circuit in
parallel. Otherwise there is a risk of damage to the device and human body.
If the tested current is over 10A, each measurement time should be less
than 10 seconds and the next test should be after 15 minutes.
7. AC measurement (only for UT131A, see Figure 3)
Similar to DC Measurement.
Please refer to Section 6 “DC measurement (see Figure 3)”
8. Battery measurement (only for UT131B, see Figure 4)
1) Switch the dial to battery test.
2) Insert the black test lead into the COM jack, the red test lead into the
“VΩmA” jack. Connect test leads with the battery in parallel.
Red test lead at positive pole “+”, black test lead at negative pole“-“
3) Battery status:
“Good”: Normal status
“Low”: Low power but still working
“Bad”: Replace/charge batteries
4) Battery display
1.5V battery
Load Resistance: 30 Ω:
“Good”: Voltage ≥1.31V
“Low”: Voltage 0.95V~1.31V
“Bad”: Voltage ≤0.94V
UT131 A UT1 31B /C/ D
Conforms to UL STD. 61010-1, 61010-2-030, Certified to
CSA STD. C22.2 No. 61010-1, 61010-2-030.
CAT II
Comply with European Union Standards
It is applicable to test and measuring circuits connected directly to
utilization points (socket outlets and similar points) of the low-voltage
MAINS installation.
Direct current
Alternating current
P/N:110401107027X
All manuals and user guides at all-guidesbox.com
all-guidesbox.com
Figure 6
9V battery
Load Resistance: 900Ω:
“Good”: Voltage≥7.8V
“Low”: Voltage 5.7V~ 7.7V
“Bad”: Voltage ≤ 5.6V
12V battery
Load Resistance: 60Ω
“Good”: Voltage ≥10.5V
“Low”: Voltage 7.6V~10.4V
“Bad”: Voltage ≤7.5V
Notes:
When the measured voltage is<0.2V (0.05V-0.19V), no indicator status
will be displayed and the reading will flash for 3 seconds for every 6
second interval.
9. Temperature measurement (only for UT131C, see Figure 5)
1) Switch the dial to temperature test.
2) Insert K-thermocouple into the device and fix the temperature probe to
the measured object. Read the value when it is stable.
Notes:
Only K-thermocouple is applicable. The measured temperature should
be less than 250˚C/482˚F (˚F=˚C*1.8+32)
10. NCV measurement (only for UT131D, see Figure 6)
1) Switch the dial to NCV position
2) Place the device near the measured object. “-” symbol indicates the
intensity of the electric field. More “-” and the higher the buzzer frequency,
the higher the electric field intensity.
3) Intensity of electric field.
“
"-": 50 ~ 100mV
"--": 100 ~ 150mV
"---": 150 ~ 200mV
"----": >200mV
EF": 0 ~ 50mV
11. Additional features
The device enters measurement status in 2 seconds after startup.
The device automatically shuts down if there is no operation for 15 minutes.
You can wake up the device by pressing any key.
To disable auto shutdown, switch the dial to OFF position, long press
HOLD key and turn on the device.
When pressing any key or switching the dial, the buzzer will beep once.
Buzzer Notification
1) Input voltage ≥250V (AC/DC), buzzer will continuously beep indicating
measure range is at limit
2) Input current >10A (AC/DC), buzzer will continuously beep indicating
measure range is at limit
1 min before auto shutdown, 5 continuous beeps.
Before shutdown, 1 long beep.
Low power warnings:
Voltage of the battery < 2.5V, symbol appears and flashes for 3 seconds
every 6 second period. During low power status, the device can still work.
Voltage of the battery < 2.2V, a solid symbol appears, the device cannot
work.
1. DC voltage
Range
Range
Range
Model
Model
Model
Resolution
Resolution
Resolution
Accuracy
Accuracy
Accuracy
2. AC voltage
3. Resistance
4. Continuity, diode
Range Resolution Remark
If the measured resistance is greater
than 50Ω, the measured circuit will be
regarded as in open status, and the
buzzer does not go off.
If the measured resistance is less
than 10Ω, the measured circuit will
be regarded as in good conduction
status, and the buzzer goes off.
Open circuit voltage: 2.1V, test
current is about 1mA
Silicon PN junction voltage is
about 0.5~0.8V.
Overload protection: 250Vrms(AC/DC)
5. Capacitance(only for UT131A)
Range Resolution Accuracy
Under REL mode±(5%+5)
6. Temperature (only for UT131C)
Range Resolution
Accuracy
IX.Technical specification
Accuracy: ±(% of reading + numerical value in least significant digit slot),
1 Year Warranty
Ambient temperature: 23˚C ±5˚C (73.4˚F±9˚F)
Ambient humidity: ≤75% RH
Notes:
To ensure accuracy, operating temperature should be within 18˚C ~28˚C.
Temperature Coefficient= 0.1*(specified accuracy)/˚C (<18˚C or>28˚C)
Input impedance: about 10MΩ ,
Results might be unstable at mV range when no load is connected. The value
becomes stable once the load is connected. Least significant digit ≤±3
Max input voltage: ±250V, when the voltage≥ 610V, "OL" symbol appears.
Overload protection: 250Vrms(AC/DC)
Input impedance: about 10MΩ ,
Frequency response: 40Hz ~ 400Hz, sine wave RMS (average response).
Max input voltage: ±250V, when the voltage ≥610V, "OL" symbol appears.
Overload protection: 250Vrms (AC/DC)
Measurement result = reading of resistor–reading of shorted test leads
Overload protection: 250Vrms (AC/DC)
Overload protection: 250Vrms(AC/DC)
Tested capacitance≤200nF, adapt REL mode.
Overload protection: 250Vrms (AC/DC)
K thermocouple is only applicable for temperature less than 250˚C/482˚F.
7. DC current
Range
Range
Model
Model
Resolution
Resolution
Accuracy
Accuracy
8. AC current (only for UT131A)
Figure 7a Figure 7b
Protective
case
Screw
Fuse
Protective
case
Screw
Input current> 10A , "OL" symbol appears and buzzer beeps
Overload protection
250Vrms
μA mA range:F1 Fuse 0.2A/250V Φ5×20mm
10A range:F2 Fuse 10A/250V Φ5×20mm
Frequency response: 40 - 400Hz.
Accuracy guarantee range: 5 -100% of the range, shorted circuit allows
least significant digit ≤2
Input current >10.10A, “OL” symbol appears with beeps
Overload protection
250Vrms
μA mA range:F1 Fuse 0.2A/250V Φ5×20 mm
10A range: F2 Fuse 10A/250V Φ5×20mm
X.Maintenance
Warning: Before opening the rear cover, switch off the power supply (remove
test leads from the input terminal and the circuit).
1. General maintenance
1) Clean the case with a damp cloth and detergent. Do not use abradants or
solvents
2) If there is any malfunction, stop using the device and send it to maintenance.
3) The maintenance and service must be conducted by qualified professionals
or designated departments.
2. Replacements (see Figure 7a, Figure 7b)
Battery replacement:
To avoid false reading, replace the battery when the battery indicator appears.
Battery Specification: AAA 1.5V x 2
1) Switch the dial to “OFF “position and remove the test leads from the input
terminal.
2) Take off the protective case. Loosen the screw on battery cover, remove the
cover to replace the battery. Please identify the positive and negative pole.
Fuse replacement:
1) Switch the dial to “OFF “position and remove the test leads from the input
terminal
2) Loosen the both screws on the rear cover, then remove the rear cover to
replace the fuse
Fuse specification
F1 Fuse 0.2A/250V Φ5×20mm ceramic tube
F2 Fuse 10A/250V Φ5×20mm Ceramic tube
UT131A/B
UT131A/C/D
UT131A/C/D
UT131A/B/C/D
UT131A
UT131A/B/C/D
UT131A
UT131A
UT131A
UT131A
UT131A/B/C/D
UT131A/B/C/D
250V
250V UT131A/B/C/D
UT131A/B/C/D
UT131A/B/C/D
UT131A/B/C/D
UT131A/B/C/D
UT131A/B/C/D
UT131A/D
Figure 5
All manuals and user guides at all-guidesbox.com

This manual suits for next models

3

Other Unit Multimeter manuals

Unit UT10A User manual

Unit

Unit UT10A User manual

Unit UT90D User manual

Unit

Unit UT90D User manual

Unit UT209 User manual

Unit

Unit UT209 User manual

Unit UT20B User manual

Unit

Unit UT20B User manual

Unit UT50A User manual

Unit

Unit UT50A User manual

Unit UT71C User manual

Unit

Unit UT71C User manual

Unit UT39A User manual

Unit

Unit UT39A User manual

Unit UT695D Series User manual

Unit

Unit UT695D Series User manual

Unit UT58E User manual

Unit

Unit UT58E User manual

Unit UT51 User manual

Unit

Unit UT51 User manual

Unit UT231 User manual

Unit

Unit UT231 User manual

Unit UT136A User manual

Unit

Unit UT136A User manual

Unit UT801 User manual

Unit

Unit UT801 User manual

Unit UT131A User manual

Unit

Unit UT131A User manual

Unit UT81B User manual

Unit

Unit UT81B User manual

Unit UT151D User manual

Unit

Unit UT151D User manual

Unit UT61D User manual

Unit

Unit UT61D User manual

Unit UT71B User manual

Unit

Unit UT71B User manual

Unit UT208A User manual

Unit

Unit UT208A User manual

Unit UT15B PRO User manual

Unit

Unit UT15B PRO User manual

Unit UT70C User manual

Unit

Unit UT70C User manual

Unit UT57 User manual

Unit

Unit UT57 User manual

Unit UT603 User manual

Unit

Unit UT603 User manual

Unit UT60C User manual

Unit

Unit UT60C User manual

Popular Multimeter manuals by other brands

Keithley 175 instruction manual

Keithley

Keithley 175 instruction manual

TDE Instruments DPM961 instruction manual

TDE Instruments

TDE Instruments DPM961 instruction manual

Kusam-meco KM 805s Operation manual

Kusam-meco

Kusam-meco KM 805s Operation manual

Picotest M3500A Service manual

Picotest

Picotest M3500A Service manual

BorMann Pro BDC2000 user manual

BorMann

BorMann Pro BDC2000 user manual

Agilent Technologies U3401A User's guide and service guide

Agilent Technologies

Agilent Technologies U3401A User's guide and service guide

General GT320 user manual

General

General GT320 user manual

Velleman DVM1500 user manual

Velleman

Velleman DVM1500 user manual

Triplett MM300 user manual

Triplett

Triplett MM300 user manual

Emos M-92A manual

Emos

Emos M-92A manual

Tektronix DM501A instruction manual

Tektronix

Tektronix DM501A instruction manual

PeakTech 3385 Operation manual

PeakTech

PeakTech 3385 Operation manual

Elenco Electronics M-2625 Operator's instruction manual

Elenco Electronics

Elenco Electronics M-2625 Operator's instruction manual

Maxwell Digital Multimeters MX 25 314 user manual

Maxwell Digital Multimeters

Maxwell Digital Multimeters MX 25 314 user manual

Megger AVO410 user manual

Megger

Megger AVO410 user manual

Ryobi RP4020 Operator's manual

Ryobi

Ryobi RP4020 Operator's manual

TSI Instruments Alnor Model AXD620 Operation and service manual

TSI Instruments

TSI Instruments Alnor Model AXD620 Operation and service manual

metex TESTLAB Y122HU operating manual

metex

metex TESTLAB Y122HU operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.