Valor GV60 MAX Installation manual

1
July 2018
Remote Control Initial Set-up
The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use.
1. Insert alkaline batteries in the remote control
receiver and handset. The receiver is located left of
the control valve under the burner module.
2. With a sharp object, press and hold the receiver’s
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
3. Within the subsequent 20 seconds, press the small
fl ame button ( ) on the remote handset until you
hear two short beeps confi rming the sychronization
is set. If you hear one long beep, this indicates the
code learning sequence has failed or the wiring is
incorrect.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.
OPERATION MANUAL
GV60 MAX
with or without optional fan
GV60 MAX Electronic Ignition Remote Control
used on Valor heaters of Series G3.5, G4, H5 and H6
For Valor heaters 700, 780, 785, 1100, 1150 and 1400 installed with or without a
fan (blower)

2
Remote Control Operation
Radio Frequency
315 MHz for USA and Canada.
This device complies with Part 15 of the FCC Rules
and with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
NOTE: Before using the remote control system for
the fi rst time, the receiver and the handset must be
synchronized. See the section Remote Control Initial Set-
up on the previous page of this manual.
IMPORTANT: BEFORE YOU BEGIN, please note that
on this system, the settings of time, temperature and
automatic ON/OFF can only be programmed when
the function display is flashing. Be patient when
programming as it can take a few seconds to set.
Note: In the TEMP or TIMER modes, the remote handset
senses the room temperature and adjusts the fl ame
accordingly.
To communicate, the handset should be within 15 feet
(4.5 meters) of the fi replace.
Do not leave the handset on the mantel or hearth.
SET (scrolls
through
modes and
settings)
OFF (returns
to set mode,
turns the burner
and the pilot o)
Large ame
button (ames
up, sets hours,
temperature)
Small ame
button (ames
down and o,
sets minutes,
temperature)
Current
temperature
(F or C)
Current time
(12 or 24 hour clock)
Modes (Manual,
Temperature, Timer)
Handset
sensor
Battery status
Current
programmed
period (Timer)
Period
start or end
(Temp, Timer)
Fan setting (if used)
When the pilot is off , it will take 2
minutes before it can be lit again.
TO TURN ON APPLIANCE TO TURN OFF APPLIANCE
FLAME HEIGHT ADJUSTMENT
On the valve, turn MAN knob on the ON, full
counterclockwise position.
Place ON/OFF switch (if equipped) in I (ON position).
STANDBY MODE (Pilot Flame)
Press and hold (small fl ame) to set appliance at
pilot fl ame.
Simultaneously press the OFF and
(large fl ame) buttons until a short
beep confi rms the start sequence has
begun; release buttons.
Continuing beeps confi rm the ignition is
in process.
Once pilot ignition is confi rmed, there is
main gas fl ow.
After main burner ignition the handset
will automatically go into manual (MAN)
control mode.
Press OFF button.
When the pilot is off , it will take 2
minutes before it can be lit again.
In standby mode: Press and hold
(large fl ame) button to increase
fl ame height.
CAUTION
When pilot ignition is confi rmed, motor turns
automatically to maximum fl ame height.

3
- Fan Mode - Turns fan ON
and OFF and adjusts fan speed.
NOTE: To turn OFF fan press
(small fl ame) until all 4
speed level bars disap-
pear.
- Light/Dimmer Setting Mode
Not available on this fi replace.
SETTING THE TIME
SETTING ºC/24-HR OR ºF/12-HR CLOCK
MODES OF OPERATION
NOTE: Manual mode can also be reached by pressing
either the (large fl ame) or the (small
fl ame) buttons.
Press and hold (small fl ame)
button to decrease fl ame height or to
set the appliance at pilot fl ame.
For fi ne adjustment tap the (large
fl ame) or (small fl ame) buttons.
Briefl y pressing the SET button
changes the mode of operation in the
following order:
→ → →
→ → → and back
to .
Double-click (small fl ame) button.
“LO” will be displayed.
NOTE: Flame goes to high fi re fi rst
before going to designated low fi re.
In MAN mode, press OFF and
(small fl ame) buttons until display
changes from Farenheit/12-hour clock
to Celsius/24-hour clock and vice
versa.
The time display will fl ash after either:
• Installing the battery or
• Simultaneously pressing the
(large fl ame) and (small fl ame)
buttons.
Press (large fl ame) button to set
the hour.
Press (small fl ame) button to set
the minute.
Press OFF or simply wait to return to
MAN mode.
Double-click (large fl ame) button.
Flame automatically goes to high fi re.
“HI” will be displayed.
- Manual Mode - Manual
Flame Height Adjustment.
Express Low and High Fire
- Daytime Temperature
Mode (Appliance must be in
standby mode; pilot ignited) - The
room temperature is measured and
compared to the set temperature.
The fl ame height is then automatically
adjusted to achieve the Daytime Set
Temperature.
x 2
x 2
MAN
MAN
MAN
TEMP
TEMP
TEMP
TIMER

4
• Briefl y press SET button to scroll
to (fan) mode. Fan and Level
icons fl ash.
• Press (large fl ame) button to
switch ON and increase fan speed.
• Press (small fl ame) button
to decrease fan speed. To turn
OFF fan, press (small fl ame)
button until all 4 speed level bars
disappear.
NOTE: 8 seconds after the fan has been set, the
handset will automatically go into temperature
control mode. The fan starts 4 minutes after
the gas opens (from OFF or from pilot) at
maximum speed and goes to the displayed
level after 10 seconds. The fan stops 10
minutes after the gas is OFF or at pilot.
- Circulating Fan - The circulating fan has 4
speed levels from low (1 bar) to high (4 bars).
CIRCULATING FAN OPERATION
(if equipped)
- Nighttime Setback
Temperature Mode (Appliance must
be in standby mode; pilot ignited) -
The room temperature is measured
and compared to the Nighttime
Setback temperature. The fl ame
height is then automatically adjusted
to achieve the Nighttime Setback
Temperature.
- Timer Mode (Appliance must
be in standby mode; pilot ignited) -
The timers P1 and P2 (Program 1,
Program 2) each can be programmed
to go ON and OFF at specifi c
times. For instructions see Timer
Programming Mode.
NOTE: The display shows the set temperature every
30 seconds.
TEMP
TIMER
Tip
Set the diff erent parameters when they are fl ashing.

5
SETTING THE ON / OFF TEMPERATURES
Briefl y press SET button to scroll
to TEMP (sun) mode.
Hold the SET button until the TEMP
fl ashes.
Press (large fl ame) button
to increase the Daytime Set
Temperature.
Press (small fl ame) button
to decrease Daytime Set
Temperature.
Press OFF or simply wait to complete
programming.
SETTING THE “DAYTIME” TEMPERATURE SETTING THE “NIGHTTIME SETBACK”
TEMPERATURE
Default Settings: (sun), 23ºC / 74ºF
Default Settings: (moon), “--” (OFF)
Press (large fl ame) button to
increase Nighttime Setback
Temperature.
Press (small fl ame) button to
decrease Nighttime Setback
Temperature.
Press OFF or simply wait to complete
programming.
Briefl y press SET button to scroll
to TEMP (moon) mode.
Hold the SET button until the TEMP
fl ashes.
TEMP
TEMP
TEMP
TEMP

6
SETTING PROGRAM TIMERS
You can program two periods of time between 12:00
am and 11:50 pm in each 24-hour cycle.
The Programs P1 and P2 must be set in the following
order during a 24-hour cycle: , ,
and .
The icon indicates the beginning of the period (ON)
and the icon indicates the end of the period (OFF).
If = or = , the programming is
cancelled.
To keep the fi replace ON all night, set at 11:50
am and at 12:00 am.
Default settings:
Program 1: 6:00 am 8:00 am
Program 2: 11:50 pm 11:50 pm
Briefl y press SET button to scroll to
TIMER mode.
Hold the SET button until
(sun) is displayed and the time
fl ashes.
Briefl y press SET button to scroll to
TIMER (moon) while the time
fl ashes.
Press (large fl ame) button to set
the hour.
Press (large fl ame) button to set
the hour.
Press (small fl ame) button to set
the minutes.
Press (small fl ame) button to set
the minutes.
SETTING P1 ON TIME SETTING P2 ON TIME
Briefl y press SET to scroll to TIMER mode (sun)
while the time fl ashes.
Follow the instructions given to set P1 ON time.
SETTING P2 OFF TIME
Briefl y press SET to scroll to TIMER mode
(moon) while the time fl ashes.
Follow the instructions given to set P1 OFF time.
Press OFF button to save these settings. The timers
are programmed. See the diagram on programming
sequences on the following page.
Tip
If you want to program only one period, program
and with desired times and program and
with the same time as .
SETTING P1 OFF TIME
P1
P1
P1
P1
P1 P1
P2
P2
P2
P2
P2
P2
P1
P1
P1
P1
P1
P1
P2
P2
P2
P2
P2

7
Miles Industries Ltd.
190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1
Tel. 604-984-3496 Fax 604-984-0246
www.valorfi replaces.com
Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.
Timer Programming Example (default temperatures shown)
6:00 a.m.—
P1
Start time
4:00 p.m.—
P2
Start time
6:00 a.m.—
P1
Start time
8:00 a.m.—
P1
End time
10:00 p.m.—
P2
End time
Set temp 74˚F Set temp 40˚FSet temp 74˚F
Set temp 40˚F
AUTOMATIC TURN DOWN
AUTOMATIC SHUT OFF
LOW BATTERY INDICATION
HANDSET / RECEIVER MATCH
Remote handset: The battery icon will show
when the battery needs to be replaced. Replace with
one 9 V alkaline battery.
Remote battery holder: Frequent ‘beeps’ for 3
seconds when the valve motor turns indicate the
batteries need to be replaced. Replace with four 1.5 V
alkaline batteries.
The remote control handset and receiver are
programmed to function together. In case of a
replacement of the handset or the receiver, you will
need to reset the receiver to allow them to function
together. Contact your dealer for details.
6 Hour no Motor Movement
Manual Mode/Temperature/Timer Mode: The valve will
turn to pilot fl ame if there is no change in fl ame height
for a 6 hour period. In Temperature/Timer Mode if the
ambient room temperature changes, the fl ame height
will adjust automatically to maintain set temperature,
and the fi re will continue to function normally. The valve
will turn to pilot fl ame if the set temperature and the
ambient room temperature remain the same over a
6 hour period.
Low batteries receiver. With low battery power in the
receiver/battery holder the system shuts off the fi re
completely. This does not apply when the power supply
is interrupted.
On-Demand Pilot. This green feature eliminates
gas energy consumption during extended appliance
inactivity. When the appliance is inactive for 5 days
the system automatically extinguishes the pilot. This
feature helps the consumer realize cost benefi ts by
automatically eliminating energy consumption during
non-heating months and limited use.
CAUTION
DO NOT USE a screwdriver or other metallic object
to remove the batteries from the battery box or the
handset! This could cause a short circuit.
Table of contents
Other Valor Remote Control manuals
Popular Remote Control manuals by other brands

SCIENTIFIC TOYS
SCIENTIFIC TOYS EZTEC Wave Hunter operating instructions

Downee
Downee Mhouse GTX4 Connecting and Operating

Anritsu
Anritsu MT9083 Series Operation manual

Universal Remote Control
Universal Remote Control MX-5000 Network Wand brochure

Logitech
Logitech HARMONY 665 Setup guide

Universal Electronics
Universal Electronics Polaris user guide