
Thank you for purchasing the Restorator by
Vaportek. This innovative appliance restores
interiors from odor contamination quickly, safely
and economically.
With proper care, your Restorator will provide years
of trouble-free service. Please read this short
manual carefully before operating your Restorator,
and keep it for future reference.
The Restorator is a simple-to-use, portable electric system
that quickly, safely and effectively neutralizes odors in
interior spaces.
As this unit does not have any “fine” output control, it is
primarily intended for fast odor-neutralizing treatment at
high intensity. The characteristic neutralizer fragrance,
therefore, will be very noticeable in operation, as the
essential oils circulate throughout the treatment area at
full output from the machine.
For initial treatment, it is suggested that the #90-5150
Industrial) or #90-4120 High-Output/Classic Neutral)
cartridge be used. The High-Output cartridge is also
available in several fragrances for follow-up treatment, if
desired. Inquire about what fragrances are available.
Place the unit where air flow at both ends is unblocked,
preferably in a relatively high location. Locate on a hard,
stable surface. Be sure the replaceable cartridge is
properly installed see instructions below), with the plastic
cap removed from the cartridge prior to installation. To
preserve cartridge life, always store with the cap on when
not in use.
Turn the unit on and allow it to deliver odor neutralizer
vapor for a few minutes. In many cases, deodorization will
be complete in 30-60 minutes. For more severe
contamination, treatment may take several hours.
Dry vapor output will be affected by humidity and
temperature. Vapor release will be significantly reduced in
excess humidity conditions 90-100%). Normal interior
conditions allow the unit to work well. Ideal temperature
range for best vapor release is 60-110° F.
The essential oils used in the membrane are non-toxic;
however, if the oils should leak, wash affected skin or
clothes with soapy water. Keep the Restorator and its
replaceable cartridge away from sources of ignition.
The Restorator is designed for use only with Vaportek-
approved replacement cartridges. Use of non-approved
replacement cartridges will void warranty coverage and
may cause risk of injury.
CONTAMINATED HOTEL ROOMS — Place the
Restorator relatively high in the treatment area
i.e., on a table/off the floor). Let run 15-30
minutes to penetrate all porous surfaces.
FIRE SMOKE DAMAGE — Close air vents and
doors in room. Let Restorator run overnight or
longer, depending on severity of damage. Residual
deodorizer vapor will dissipate in a few hours after
treatment and imbedded malodors will be
eliminated.
AUTO BOAT RESTORATION — The Restorator is
ideal for removing cigarette, food, mustiness and
other biological odors in cars, recreational vehicles,
boats, etc. Run in closed treatment area for 15-30
minutes light malodor problem) to 2-3 hours or
more for severe odor problems).
IDEAL FOR REAL ESTATE, CLEANING AND
CRIME SCENE SERVICES; MORTUARIES;
MEETING ROOMS; AUTO RENTAL AGENCIES;
USED CAR DEALERS, DETAIL SHOPS...AND
COUNTLESS OTHER APPLICATIONS WHERE
PROBLEM ODORS EXIST!
THANK YOU!
SOME SUGGESTED USES
INSTRUCTIONS
Place cartridge into back of
machine with open end of
cartridge inserted first. (If
substantial oil leakage
[dripping] is evident, do not
use. Re-cap and contact
dealer or aportek.)
Be sure cartridge is
positioned properly
in the internal
cradle, with open
end resting against
the black gasket.
Fg 1 Fg 2 Fg 3
Fg 4 Fg 5
Lift off lid and discard clear
film liner. (Slight wetness
under cap is normal.)
To operate, plug cord into
appropriate power outlet. Always
unplug Restorator before removing
cartridge. To prolong cartridge life,
remove from machine, re-cap and
store cartridge upright in a cool, dry
place. The Restorator cord can be
coiled for storage in the back of the
rear cover plate.
When machine is in use,
the plastic lid can be
stored at the back end of
the cartridge inside the
machine.
Replace spring-
loaded rear cover
plate by pressing it
against the cartridge
while turning, until it
locks into place.
Fg 6