Vega VEGAMIP 60 Series User manual

Operating Instructions
Electronics module
VEGAMIP series 60 -emitting unit
VEGAMIP series 60 -receiving unit
Document ID:
37349
Radar

Contents
1About this document
1.1Function.................................. 3
1.2Target group .............................. 3
1.3Symbolism used............................ 3
2For your safety
2.1Authorised personnel ........................ 4
2.2Appropriate use ............................ 4
2.3Environmental instructions..................... 4
3Product description
3.1Configuration .............................. 5
3.2Principle of operation ........................ 5
3.3Packaging,transport and storage ............... 5
4Mounting
4.1Instructions for installation ..................... 7
4.2Mounting preparations ....................... 7
4.3Mounting steps............................. 7
5Setup
5.1Setup.................................... 10
6Maintain
6.1How to proceed in case of repair................ 11
7Dismounting
7.1Dismounting steps .......................... 12
7.2Disposal ................................. 12
8Supplement
8.1Technical data ............................. 13
Safety instructions for Ex areas
Please note the Ex-specific safety information for installation and
operation in Ex areas.These safety instructions are part of the
operating instructions manual and come with the Ex-approved
instruments.
2Electronics module •VEGAMIP series 60 -receiving unit
Contents
37349-EN-121205

1About this document
1.1Function
This operating instructions manual provides all the information you
need for mounting,connection and setup as well as important
instructions for maintenance and fault rectification.Please read this
information before putting the instrument into operation and keep this
manual accessible in the immediate vicinity of the device.
1.2Target group
This operating instructions manual is directed to trained qualified
personnel.The contents of this manual should be made available to
these personnel and put into practice by them.
1.3Symbolism used
Information,tip,note
This symbol indicates helpful additional information.
Caution:If this warning is ignored,faults or malfunctions can
result.
Warning:If this warning is ignored,injury to persons and/or serious
damage to the instrument can result.
Danger:If this warning is ignored,serious injury to persons and/or
destruction of the instrument can result.
Exapplications
This symbol indicates special instructions for Ex applications.
lList
The dot set in front indicates a list with no implied sequence.
àAction
This arrow indicates a single action.
1Sequence
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of
batteries and accumulators.
Electronics module •VEGAMIP series 60 -receiving unit 3
1About this document
37349-EN-121205

2For your safety
2.1Authorised personnel
All operations described in this operating instructions manual must be
carried out only by trained specialist personnel authorised by the plant
operator.
During work on and with the device the required personal protective
equipment must always be worn.
2.2Appropriate use
The components such as electronics module,accumulator insert,
emitting electronics,housing or process components described in this
manual are replacement components for existing sensors.
2.3Environmental instructions
Protection of the environment is one of our most important duties.That
is why we have introduced an environment management system with
the goal of continuously improving company environmental protection.
The environment management system is certified according to
DIN EN ISO 14001.
Please help us fulfil this obligation by observing the environmental
instructions in this manual:
lChapter "Packaging,transport and storage"
lChapter "Disposal"
4Electronics module •VEGAMIP series 60 -receiving unit
2For your safety
37349-EN-121205

3Product description
3.1Configuration
The scope of delivery encompasses:
lElectronics module for emitting unit VEGAMIP series 60
(MP60EE.T**) or electronics module for receiving unit VEGAMIP
series 60 (MP60EE.R**)
lDocumentation
-this operating instructions manual
3.2Principle of operation
The electronics module MP60 is suitable as a replacement for the
electronics of microwave barrier VEGAMIP series 60.
3.3Packaging,transport and storage
Your instrument was protected by packaging during transport.Its
capacity to handle normal loads during transport is assured by a test
according to DIN EN 24180.
The packaging of standard instruments consists of environment-
friendly,recyclable cardboard.For special versions,PE foam or PE foil
is also used.Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out under consideration of the notes on the
transport packaging.Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt.Ascertained transit damage or
concealed defects must be appropriately dealt with.
Up to the time of installation,the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated,the packages must be stored only under
the following conditions:
lNot in the open
lDry and dust free
lNot exposed to corrosive media
lProtected against solar radiation
lAvoiding mechanical shock and vibration
lStorage and transport temperature see chapter "Supplement -
Technical data -Ambient conditions"
Scope of delivery
Application area
Packaging
Transport
Transport inspection
Storage
Storage and transport
temperature
Electronics module •VEGAMIP series 60 -receiving unit 5
3Product description
37349-EN-121205

lRelative humidity 20 …85 %
6Electronics module •VEGAMIP series 60 -receiving unit
3Product description
37349-EN-121205

4Mounting
4.1Instructions for installation
If the electronics module is defective,it can be replaced by the user.
InEx applications only one instrument and one electronics module with
respective Ex approval may be used.
4.2Mounting preparations
Keep in mind that the emitting and receiving unit require special
electronics modules.
lEmitting unit -electronics module MP60EE.T**
lReceiving unit -electronics module MP60EE.R**
4.3Mounting steps
To exchange the electronics module,proceed as follows:
1Switch offpower supply
2Unscrew the housing cover
3Lift the terminal block with a small screwdriver and pull it out.
4Loosen the two screws with a screw driver (Torx size T10 or slot 4)
2
1
Fig.1:Loosening the holding screws
1Electronics module
2Screws (2pcs.)
5Pull out the old electronics module
6Compare the new electronics module with the old one.The type
label of the electronics module must correspond to that of the old
electronics module.This applies particularly to instruments used in
hazardous areas.
7Insert the electronics module carefully.Make sure that the plug is
in the correct position.
Electronics module -
emitting unit MP60EE.
T**
Electronics module •VEGAMIP series 60 -receiving unit 7
4Mounting
37349-EN-121205

Information:
Make sure that the housing is not rotated during the electronics
exchange.Otherwise the plug may be in a different position later.
8Screw in the two holding screws and tighten them
9Insert the terminal block again.You must hear it snap in.
10 Screw the housing cover back on
The electronics exchange is now finished.
As a rule,an exchange of electronics must be documented internally
when Ex applications are involved.
To exchange the electronics module,proceed as follows:
1Switch offpower supply
2Unscrew the housing cover
3Lift the terminal blocks with a small screwdriver and pull them out.
4Loosen the two screws with a screw driver (Torx size T10 or slot 4)
2
1
Fig.2:Loosening the holding screws
1Electronics module
2Screws (2pcs.)
5Pull out the old electronics module
6Compare the new electronics module with the old one.The type
label of the electronics module must correspond to that of the old
electronics module.This applies particularly to instruments used in
hazardous areas.
7Insert the electronics module carefully.Make sure that the plug is
in the correct position.
Information:
Make sure that the housing is not rotated during the electronics
exchange.Otherwise the plug may be in a different position later.
8Screw in the two holding screws and tighten them
9Insert the terminal blocks again.You must hear them snap in.
Electronics module -re-
ceiving unit MP60EE.R**
8Electronics module •VEGAMIP series 60 -receiving unit
4Mounting
37349-EN-121205

10 Carry out the adjustment according to the operating instructions of
the sensor
11 Screw the housing cover back on
The electronics exchange is now finished.
As a rule,an exchange of electronics must be documented internally
when Ex applications are involved.
Electronics module •VEGAMIP series 60 -receiving unit 9
4Mounting
37349-EN-121205

5Setup
5.1Setup
After having exchanged the electronics module,the complete setup
must be carried out.
The adjustment should be carried out according to the description in
the operating instructions manual.
Setup
10 Electronics module •VEGAMIP series 60 -receiving unit
5Setup
37349-EN-121205

6Maintain
6.1How to proceed in case of repair
You can find a repair form as well as detailed information on how to
proceed under www.vega.com/downloads and "Forms and certifi-
cates".
By doing this you help us carry out the repair quickly and without
having to call back for needed information.
If a repair is necessary,please proceed as follows:
lPrint and fill out one form per instrument
lClean the instrument and pack it damage-proof
lAttach the completed form and,if need be,also a safety data
sheet outside on the packaging
lPlease contact for the return shipment the agency serving you.
You can find the agency on our home page www.vega.com.
Electronics module •VEGAMIP series 60 -receiving unit 11
6Maintain
37349-EN-121205

7Dismounting
7.1Dismounting steps
Warning:
Before dismounting,be aware of dangerous process conditions such
as e.g.pressure in the vessel,high temperatures,corrosive or toxic
products etc.
Take note of chapters "Mounting"and "Connecting to power supply"
and carry out the listed steps in reverse order.
7.2Disposal
The instrument consists of materials which can be recycled by
specialised recycling companies.We use recyclable materials and
have designed the parts to be easily separable.
Correct disposal avoids negative effects on humans and the environ-
ment and ensures recycling of useful raw materials.
Materials:see chapter "Technical data"
If you have no way to dispose of the old instrument properly,please
contact us concerning return and disposal.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/EG and
the respective national laws.Pass the instrument directly on to a
specialised recycling company and do not use the municipal collecting
points.These may be used only for privately used products according
to the WEEE directive.
12 Electronics module •VEGAMIP series 60 -receiving unit
7Dismounting
37349-EN-121205

8Supplement
8.1Technical data
Technical data
are stated in the operating instructions manual of the respective sensor.
Electronics module •VEGAMIP series 60 -receiving unit 13
8Supplement
37349-EN-121205

14 Electronics module •VEGAMIP series 60 -receiving unit
8Supplement
37349-EN-121205

Electronics module •VEGAMIP series 60 -receiving unit 15
8Supplement
37349-EN-121205

ISO 9001
All statements concerning scope of delivery,application,
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
©VEGA Grieshaber KG,Schiltach/Germany 2012
Subject to change without prior notice 37349-EN-121205
This manual suits for next models
1
Table of contents
Other Vega Control Unit manuals

Vega
Vega VEGAKON 61 User manual

Vega
Vega VEGAFLEX 66 User manual

Vega
Vega VEGASWING 66 User manual

Vega
Vega VEGADIS 176 Ex Installation instructions

Vega
Vega VEGAPULS 6X User manual

Vega
Vega plicscom User manual

Vega
Vega VEGACAL 60 Series User manual

Vega
Vega VEGADIF 65 User manual

Vega
Vega VEGAKON 66 User manual

Vega
Vega PT30E.SV User manual

Vega
Vega VEGADIS 81 User manual

Vega
Vega VEGACAP 60 Series User manual

Vega
Vega VEGAKON 66 User manual

Vega
Vega VEGABAR 80 Series User manual

Vega
Vega VEGATOR 132 User manual

Vega
Vega plicscom User manual

Vega
Vega VEGABAR series 80 User manual

Vega
Vega VEGASON S 62 User manual

Vega
Vega PLICSMOBILE 80 Series User manual