PIR050
V. 02 – 16/11/2016 6 ©Velleman nv
1. Test the detector at the point of time you feel the lamp needs to
be switched on.
2. Turn the LUX knob fully clockwise; turn the TIME knob fully anti-
clockwise.
3. Switch on the power. The detector needs a warm-up time of
± 30 seconds before it will switch on the connected lamp. When
no signal is detected, the lamp will switch off after
± 10 seconds.
4. Turn the LUX knob fully anti-clockwise. The lamp should switch
off.
4.5 Setting the Detector
1. Turn the LUX knob until the lamp switches on.
2. Now, set the switch-off delay with the TIME knob going from
± 10 seconds to ± 15 minutes.
3. Close the detector with the cover and tighten the screw.
5. Cleaning and Maintenance
The detector does not need any particular maintenance. However,
occasionally wipe it with a damp cloth to keep it looking new. Do not
use harsh chemicals, cleaning solvents or strong detergents.
6. Technical Specifications
power supply ................................. 220-240 VAC, 50 Hz
detection range .............................................6 m max.
detection angle.................................................... 360°
ambient light......................... < 3 - 2000 lux (adjustable)
installation height ..........................................2.2 - 4 m
power consumption ..........................................± 0.5 W
motion speed detection ..............................0.6 - 1.5 m/s
working temperature ...........................-20 °C to + 40 °C
working humidity ......................................... < 93% RH
max. rated load
resistive.....................................2000 W (230 VAC)
inductive ....................................1000 W (230 VAC)