Page 2 z 10
Venture Industries Sp. z o.o.
Mokra 27 Street
05-092 Łomianki-Kiełpin
Poland
OPERATION AND MONTAGE MANUAL
No RFEC/U/2017- 2 (EN)
tel. (0-22) 7519550; 7512031, fax (0-22) 7512259; 7511202, e-mail: venture@venture.pl
INTRODUCTION
This manual covers fans in standard version, listed on the title page and it is source of information necessary for safe and
proper use. Read this manual carefully before any use of the device, comply with it requirements and keep it in place with easy
access for users and service. If case of any doubts about use of the fan, please contact with manufacturer.
After receiving the device - check
• whether the device is in compliance with order,
• whether the data on the rating plate are the same as desired (voltage, frequency, etc.)
• whether fan was not damaged during transport (e.g. there are no dents/cracks, impeller rotates freely)
In case of any irregularities, contact with your dealer or Venture Industries Sp. z o.o. service.
1. GENERAL INFORMATION
1.1 Information about device
• The fan is a not completed machine within the meaning of the Machinery Directive 2006/42/WE (please refer to the manufacturer's
declaration –Appendix C). Product is in conformity with the Commission Regulation (EU) No 1253/2014 implementing ErP Directive
2009/125/EC with regard to eco-design requirements for ventilation units. Additional information can be found on the manufacturer's website
(www.ventur.eu).• Fan is designed for use by trained, qualified adult persons. The fan is not designed for household and similar use.
• The device is designed to transport clean air or air with low level of contamination. Do not transport the explosive mixtures, liquids, viscous
substances, substances with high humidity, substances that cause erosion, solid elements, and chemically reactive compounds - we
recommend the use of suitable filters. The maximum temperature of transported medium is specified on the fan nameplate, the minimum
is -20°C.
• The fan is designed for outdoor use. It must be protected from effects of lightning. The fan surroundings cannot contain explosives
atmospheres, substances causing abrasion, chemically aggressive substances and viscous substances. The maximum ambient temperature is
specified on the fan nameplate, minimum is -20°C (or lower – if confirmed by the manufacturer).
• The fan with EC type motor (electronically commutated) has built-in speed regulator (see chapter 4.2 - Guidelines for regulation) with soft
start and protections against effects of blocked impeller, overload, overheating, voltage drop or overvoltage.
• The fan has a removable cover – in order to gain access to the fan interior, move the cover after releasing the fasteners.
● The fan has following marks:
-warnings and information (optional): information about risk associated with use of the fan and about correct fan installation and operation
-fan nameplate with: logo and manufacturers name (Venture Industries Sp. z o.o.); full fan name; basic information –supply voltage and
frequency, rated current, maximum temperature of ambient and transported medium (Temp. max. or Temp. ambient max.), weight (Weight),
type of work; type of fan motor (Motor); information according to conformity with ERP Directive; article no. (Art. No.) serial no. (No.).
-direction arrows: information about correct direction of impeller rotation (rotation arrow can be placed on nameplate)
1.2 General risk and guidelines
During entire fan life cycle pay particular attention to the risk and guidelines presented below:
1.2.1 Mechanical risk and guidelines
• The fan has moving elements (e.g. impeller). Do not use the fan without installed proper protection structures (e.g. guards on inlet and
outlet) protecting from contact with moving elements. Prevent from opening the fan by unauthorized persons
• The fan has high suction power. Clothing, hair, assembly elements, items, and even body elements can be easily sucked in.
Make sure that before start and during operation of the fan, near the fan inlet there is no person and items which can be
sucked. It is forbidden to approach the fan in “loose” clothing or reaching toward inlet of working fan. Use appropriate inlet
covers and If necessary –use relevant protective clothing (e.g. headgears).
Warning: Risk of serious injury.
• The air at the outlet of the fan has high energy. Elements sucked or placed inside the fan can be thrown with a high speed. In case of damage
or improper operation, parts (with high kinetic energy) can be thrown out from fan. It is forbidden to look into the fan reaching toward inlet
and outlet of the working fan. Make sure that before start and during operation of the fan there is no person on inlet side and in stream of
transported medium. Do not use fan without proper safety constructions, inlet and outlet covers.
• During manufacturing the fan sharp edges was grinded. However the fan may have edges touching which may cause injury. We recommend
the use of relevant protective gloves.
• Conveying equipments and fan support structures must by selected proper to the fan weight and ensure that fan would not move. Do not
approach the hanging load during transport.
• The fan has a high inertness. In case of no permanent fix turning on the fan will lead to it uncontrolled movement. The unit can work only
after proper installation.
• Uncontrolled start of the fan can create hazard situation. Prevent against unexpected start of the fan – see also 1.2.6.
1.2.2 risk and guidelines related with noise
• The sound pressure level is not the same over the fan whole range. We recommend to check the sound pressure level and if
necessary use the silencer and relevant sound protection.
1.2.3 risk and guidelines related with used materials
• In case of fire or transport of improper medium – fan parts can generate fumes hazardous to health. See also 1.2.5.
1.2.4 risk and guidelines related with environment