First of all, thank you for purchasing a Veton Wall Plus charging station. We are proud of our
craftsmanship and hope you enjoy it just as much.
Please read the operating instructions carefully. It contains, in addition to essential information
on installation and use, important safety information, as well as the serial number of the Veton
Wall Plus charging station.
As our product is an application and assembly of electrical systems, this installation must
be carried out by a competent installer. For this reason, it is also strongly discouraged to
disassemble the assembly carried out by Veton.
Incorrect installation or (re-)assembly may lead to, among other things, short-circuits, fire and/
or smoke, and serious bodily injury. Veton cannot be held liable for damage to persons, animals
and/or objects resulting from non-compliance with the requirements in this manual.
Veton reserves the right to make any changes to the product (and/or its technical
characteristics), and the instructions for use and/or installation, at any time and without prior
notice.
If in doubt, always contact a professional or distributor of Veton products.
Foreword.
EN

4User manual - EN
1. General provisions
Purpose of the document.
Handling this manual.
Regulatory use.
Warranty and liability.
Use of symbols and highlighting.
This operating and installation manual is part of the product and contains information for the user to safely operate the Veton
Wall Plus charging point and for an authorized electrician to safely install it.
• Read the operation and installation manual before installing and commissioning the Veton Wall Plus
charging station.
• Keep this manual within reach.
• Pass this manual on to a subsequent owner or user of the charging station (this document contains the
serial number).
• The voltage is switched on only when the vehicle is connected correctly.
• The maximum current is adjusted.
• The AC/DC converter is located inside the vehicle.
The Veton Wall Plus charging station is suitable for charging electric vehicles in accordance with IEC 61851-1, charging mode
3. In this charging mode, the charging station ensures that:
Veton is not liable for defects and damage that can be traced back to non-observance of the operating and installation
instructions. This exclusion of liability applies in particular to:
Danger.
High-risk hazard which, if not avoided, could result in death or serious injury.
indication.
The indication explains a technical peculiarity or possible damage to the product, if ignored.
• Improper use.
• Installation and commissioning by an unauthorized electrician.
• Repairs not carried out by a Veton service center.
• Use of non-original spare parts.
• Conversion of the device without explicit permission from Veton.

5User manual - EN
General.
The charging station may only be used by persons over 18 years of age.
The Veton Wall Plus charging station has been developed, manufactured, tested and documented in accordance with the
relevant safety and environmental regulations.
Only operate the device in a technically perfect condition. Faults that adversely aect the safety of persons or the device
must be rectified immediately by an authorized electrician in accordance with the nationally applicable regulations. The
signaling in the vehicle may dier from this description. For this, the operating instructions of the respective vehicle
manufacturer should always be read and observed.
General safety instructions.
• Dangerously high voltages in the device.
• Check the charging station for optical damage before use. Do not use the charging station if it is damaged.
• Installation, electrical connection and commissioning of the charging station may only be carried out by an
authorized electrician.
• Do not remove markings, warning symbols or rating plate from the charging station.
• The charging cable or charging outlet should only be replaced by an authorized electrician according to the
instructions.
• It is strictly forbidden to connect other devices to the charging station.
• Wall Plus - Plug: when the charging cable is not in use, store it in the provided holder.
• Wall Plus - Socket: when the charging outlet is not in use, ensure it is covered.
• Ensure that the charging cable is protected from being run over or trapped and other mechanical hazards.
• If the charging station or charging cable/outlet is damaged, notify the service center immediately. Do not use the
charging station again.
• No persons should be in the vehicle during the charging process.
• Protect the charging cable/outlet from contact with external heat sources, water, dirt and chemicals.
• Do not extend the charging cable with an extension cable or adapter to connect it to the vehicle.
• Remove the charging cable only by pulling the charging plug.
• Never clean the charging station with a pressure washer or similar device.
• Switch o the electric external power supply before cleaning the charging station.
• Ensure that only persons who have read these operating instructions have access to the charging station.
Safety instructions for the installation.
• Installation and connection of the charging station should only be carried out by an authorized electrician.
• Use only the supplied mounting material.
• The Veton Wall Plus safety concept is based on an earthing system that must always be guaranteed. The
authorized electrician must ensure this during installation.
• Do not install the charging station in an explosive environment (Ex zone).
• Install the charging station so that the charging cable does not block passage.
• Do not install the charging station in environments with ammonia or ammonia-containing air.
• Do not mount the charging station where it could be damaged by falling objects (e.g. cable drums or tyres).
• Do not install the charging station near installations that spray water, e.g. car washes, pressure washers or
2. Safety

6User manual - EN
garden hoses.
• Set up the charging station in such a way as to prevent vehicles from inadvertently driving into it and damaging it.
If damage cannot be excluded, take protective measures.
• If the charging station is damaged during installation, it must be taken out of service. It must be replaced.
Safety instructions for the electrical connection.
• You should take into account local legal requirements for electrical installations, fire protection, safety regulations
and escape routes at the planned installation location.
• Ensure that the electrical connections are de-energized before connecting the charging station to electricity.
• When commissioning the charging station for the first time, do not connect a vehicle yet.
• Ensure that the correct connecting cable is used for connection to the mains.
• Do not leave the charging station unattended when the installation cover is open.
• Do not install the charging station without an installation frame.
• Observe any notifications to the grid operator.
Safety instructions for commissioning.
• Commissioning of the charging station must only be carried out by an authorized electrician.
• The correct connection of the charging station must be checked by the authorized electrician before
commissioning.
• Before commissioning the charging station, check the charging station and charging outlet for optical damage. It
is not permitted to commission a damaged charging station or a charging station with a damaged charging outlet.

7User manual - EN
Charging station packaging contents
• 1 x Veton Wall Plus charging station
• 1 x Phoenix Contact charging cable (20A)*
• 1 x Veton Wall/Wall Plus mounting plate (including 4 x bolt anchors** - 8 x 71 mm)
• 1 x BBC Cellpack EasyCell® gel box
• 3M Scotchlok™ clamps (number depending on optional extras chosen)
Installation cabinet contents
• 1 x Veton Components Cabinet (components available separately on request)
* A charging cable is only delivered for model Wall Plus - Plug.
** The installation described in this manual uses bolt anchors for the installation. Alternative methods are possible.
3. Scope of delivery

8User manual - EN
4. Technical specifications
Charging controller
Overload protection
OCPP compatibility
Open platform
Component housing
Phoenix Contact Charx SEC Series
Dynamic load balancing
Connect with provider of choice
For own applications
Built-in utility closet
SEC-3XXX / SEC-1000 Optional 4G/2G connection
Optional MID certified monitor required
PLC Next based
450 x 315 x 155 mm
Connectivity
Web application
Energy monitoring (optional)
Residual Current Detection
Cable
Charger housing
Ethernet, MQTT, Modbus TCP/RTU, REST API
Integrated web app to manage
charging sessions
1 x MID certified energy monitor
Built-in Type B RCD / Residual Current Monitor
5G 6mm2 + 3 to 12 x 0.25mm2 (UTP/SVV)
Powder coated steel & aluminium
Calculation of transaction costs
Charging specifications
Charging output
Authentication
Dimensions
Max. cable distance
Mode 3 charging capability 3,7 - 22kW*
Type 2 charging cable/outlet
Optional RFID integration
350 x 350 x 150 mm
100 meters
3 x 400V+N (16A - 32A per phase)
20A / 32A
Between components and charger
30mA AC/DC Type B or 6mA DC / 30mA AC Monitor H x W x D
Between components and charger
Ambient lighting
LED courtesy light
Separate control
* For model Wall Plus - Plug there’s a maximum charging capability of 13,5kWh.

9User manual - EN
5. Installation
This manual describes the (basic) installation of a Veton Wall Plus charging station. For reasons ranging from sustainability
to modularity, the actual charging point and the electrical charging components are separated. The charging point is installed
within reach of the vehicle(s), the charging components are placed in an installation cabinet, or other DIN-rail compatible
cabinet.
The description of the installation in this chapter is limited to the placement of the charging station and the connection to
the above-mentioned electrical charging components (cables to be laid prior to installation). The connection of the charging
infrastructure to the current electrical installation is possible in several ways, and should be carried out with the professional
judgment of an experienced electrician.
Tools and materials needed.
• Drill
• Concrete drill bit - 8 mm
• Socket spanner
• (Extended) socket spanner attachment - 13 mm
• Allen spanner - 2.5 mm (included with BBC Cellpack EasyCell® gel box)
• Allen spanner - 3 mm

10 User manual - EN
1
1. Hang the electrical cabinet*.
Attach the electrical cabinet supplied with the charging components near the electrical set-up of the property.
* This step only applies if your electric charging components were supplied in an installation cabinet.

11 User manual - EN
2. Mark holes and drill.
Use the mounting plate as a stencil to drill the holes for the bolt anchors (step 3). Subsequently, drill 8 millimeter holes on
these markings, about 6 cm deep. The bolt anchors should stick about 2 cm outside the wall.
2

12 User manual - EN
3. Insert bolt anchors.
Insert the 4 bolt anchors (M8) into the holes by means of a hammer. Make sure the bolts stick out about 2 cm.
3

13 User manual - EN
4. Attach mounting plate and box.
Slide the mounting plate over the bolt anchors and subsequently do the same with the box. If desirable, insert the cables
through the cable glands beforehand (see step 5). Attach the box and mounting plate with the provided nuts (M8).
4

14 User manual - EN
5. Insert cables.
Insert the cables originating from the electrical cabinet into the cable glands and fix them tightly. Make sure that the cable is
long enough to make connections inside the box.
5

15 User manual - EN
6. Connections.
Wall Plus - Plug
Connect the power cable from the contactor to the charging cable by screwing the corresponding wires into the terminal
block included with the supplied BBC Cellpack EasyCell® gel box.
Place the terminal block with the fastened cables in the provided BBC Cellpack EasyCell® gel box. Then close it until a clear
click sound is heard.
To connect the LED light, Control Pilot and RFID reader (optional), Scotchlok™ clamps are included.
Connect the above mentioned cables in the cabinet to the corresponding cables from the cabinet according to the electrical
diagram.
Installing a Wall Plus - Socket? Proceed to the next page. 6
L1
L2
L3
N
12V
A+
GND
B-
CP
PE
Contactor
LED
RFID
Type 2
Connector
RCM 6mA DC

16 User manual - EN
6
Wall Plus - Socket
Connect the power cable from the contactor to the charging outlet by screwing the corresponding wires into the terminal
blocks included with the supplied BBC Cellpack EasyCell® gel box.
Place the terminal block with the fastened cables in the provided BBC Cellpack EasyCell® gel box. Then close the boxes until
a clear click sound is heard.
To connect the LED light, Proximity Pilot, Control Pilot and RFID reader (optional), Scotchlok™ clamps are included.
Connect the above mentioned cables in the cabinet to the corresponding cables from the cabinet according to the electrical
diagram.
L1
L2
L3
N
12V
A+
GND
B-
CP (1 mm)
LO- (0,5 mm)
LD1 (0,5 mm)
PP (1 mm)
LO+ (0,5 mm)
LD2 (0,5 mm)
PE
Contactor
RFID
RCM 6mA DC
Type 2
Outlet
LED

17 User manual - EN
7. Attach front plate.
Position the front plate in front of the box. Make sure the 2 hooks are positioned at the bottom, and the hook on top is aligned
with the provided opening inside the box. Insert the front plate through the opening and tilt so the bottom hooks can be
inserted into the provided slots. Slide upwards so the bottom hooks are aligned with the slots, and gently push forwards. The
top hook should snap into the cavity in the upper part of the box.
Attach the front plate with the 2 provided countersunk screws (M5).
7

18 User manual - EN
8. Configuration.
The basic controller settings have already been set up, prior to delivery. For more information on setting up the web interface,
please refer to the documentation at www.veton.be/quickstart-guides.
8

19 User manual - EN
6. Operation.
Wall Plus - Plug
Your Veton Wall Plus (Plug) charging station has been installed, inspected, and is ready for use. This section of the manual
describes how to use the charging station, and what to consider to safely use it.
Always consider the vehicle requirements before starting vehicle charging.
Park the vehicle at the charging station in such a way that the charging câble is not tense.
Insert the charging plug into the car’s charging port.
Scan RFID (if applicable).
Start charging
Open the door of the charging station.
Remove the charging cable from the holder (Wall Plus - Plug).
Close the door of the Wall Plus.

20 User manual - EN
Interrupt the charging process on the vehicle side and
remove the plug (this step is vehicle-specific).
Stop charging
Close the door of the Wall Plus.
Insert the connector into the Wall Plus’s cradle.Open the door of the charging station.
This manual suits for next models
1
Table of contents
Other VETON Batteries Charger manuals
Popular Batteries Charger manuals by other brands

Elettro C.F.
Elettro C.F. LEM1224250 operating instructions

I-GO
I-GO LAPTOP TRAVEL CHARGER IGO GREEN - QUICK GUIDE... quick guide

Meanwell
Meanwell PB-1000 instruction manual

Sema Connect
Sema Connect 7 Series installation manual

MICRO-POWER
MICRO-POWER STC Series user manual

GOAL ZERO
GOAL ZERO GUIDE 12 user guide