UG:120 Page 8
OUTPUTS M1 & M2 OUTPUTS M3 & M4
18 PIN MOLEX OUTPUT CONNECTORS
J2 J3
+V OUT M2
-V OUT M2
-V OUT M2
+V OUT M2
- VOUT M2
TRIM M1
+V OUT M1
+V OUT M1
-V OUT M1
PIN DESCRIPTION
10 +V OUT M2
11 +V OUT M2
12 -V OUT M2
13 + VOUT M1
14 TRIM M2
15 - VOUT M1
16 +V OUT M1
17 - V OUT M1
18 - V OUT M1
PIN DESCRIPTION
1 +V OUT M4
2 -V OUT M4
3 -V OUT M4
4 + SENSE M4
5 - SENSE M4
6 TRIM M3
7 +V OUT M3
8 +V OUT M3
9 -V OUT M3
PIN DESCRIPTION
10 +V OUT M4
11 +V OUT M4
12 -V OUT M4
13 + VOUT M3
14 TRIM M4
15 - VOUT M3
16 +V OUT M3
17 - V OUT M3
18 - V OUT M3
1
9
1018
1
9
1018
OUTPUT M1 OUTPUT M2
10-32 STUDS
+
M2
J2
-
M1
-
J1
+
STUD OUTPUT CONNECTORS
1
23
1 Trim Pin
2 + Remote Sense
3 - Remote Sense
Pin
OUTPUTS M2 & M3
OUTPUT M1
18 PIN MOLEX OUTPUT CONNECTORS
J2 J3
J2-13 + SENSE M1
J2-15 - SENSE M1
J3-4 + SENSE M3
J3-5 - SENSE M3
J3-13 + SENSE M2
J3-15 - SENSE M2
1
18
9
10
1
9
10
18
+S
-S
+S
-S
+S
-S
OUTPUTS M1 & M2 OUTPUTS M3 & M4
18 PIN OUTPUT CONNECTORS
J2 J3
M4 accepts 1 Mini or 1
Junior
J3-4 + SENSE M4
J3-5 - SENSE M4
1
9
1018
1
9
1018
M1, M2, M3 accept Micro modules
No sense connections are available
for Micro modules
+S
-S
Installing power connectors on outputs with 18-pin Molex connectors
(only half and/or quarter bricks used):
The output M1 slot only accepts a Micro module. J2-7, J2-8, J2-13 and J2-16 are positive,
while pins J2-9, J2-15, J2-17 and J2-18 are the returns.
The output M2 slot only accepts a Micro module. J2-1, J2-4, J2-10, J2-11 are positive,
while pins J2-2, J2-3, J2-5 and J2-12 are the returns.
The output M3 slot only accepts a Micro module. J3-7, J3-8, J3-13 and J3-16 are positive,
while pins J3-9, J3-15, J3-17 and J3-18 are the returns.
The output M4 slot only accepts either a Mini or a Junior module. J3-1, J3-10 and J3-11 are positive,
while pins J3-2, J3-3, and J3-12 are the returns.
For this 18-pin housing, use Molex mating receptacle #39-01-2180 with #39-00-0039 terminals.
Attach 18 – 24AWG stranded wire using Molex tool #11-01-0197
Note: The molex connectors are limited to 9A/pin (27A per output).
See Page 11 for detailed diagrams of output connections.
Sense Connections
The FlatPAC-EN™/EN MI is shipped with Autosense installed.
(For more information on Autosense, refer to Page 18.)
Sense Connections for stud outputs (only full and/or half bricks used):
For Remote Sense, connect remote-sense wires to Remote SENSE/TRIM pin access
connector J1 or J2 for single output and J1/J2 for dual outputs.
Note: Connector pins J1-2 and J2-2 are the +SENSEs and J1-3 and J2-3 are the –SENSEs.
Use Molex mating receptacle #50-57-9403 with #16-02-0103 terminals.
Attach terminals to 24 – 30AWG stranded twisted pair wire using
Molex tool #11-01-0208.
Attach opposite end of sense lines to their respective outputs to point where
regulation is desired. Verify that sense lines are not cross-connected.
Sense Connections on 18-pin molex output connectors (only half bricks used):
If Remote Sense is desired, connect remote-sense wires to the sense lines of
Connector J2 for output 1 and J3 for outputs 2 and 3.
For Output M1, J2-13 is the +SENSE and J2-15 is the –SENSE.
For Output M2, J3-13 is the +SENSE andJ3-15 is the –SENSE.
For Output M3, J3-4 is the +SENSE and J3-5 is the –SENSE.
Use Molex mating receptacle #39-01-2180 with #39-00-0039 terminals.
Attach 18 – 24AWG stranded twisted pair wire using Molex tool #11-01-0197.
Sense Connections on 18-pin output connectors (only half and/or quarter bricks used):
If Remote Sense is desired (available only on output M4),
connect remote-sense wires to sense lines of Connector J3.
Remote Sense is NOT available for Micro modules and hence is not available on
outputs M1, M2 and M3.
On output M4, J3-4 is the +SENSE and J3-5 is the –SENSE.
Use Molex mating receptacle #39-01-2180 with #39-00-0039 terminals.
Attach 18 – 24AWG stranded twisted pair wire using Molex tool #11-01-0197