Victor 81A User manual

VICTOR
VICTOR
VICTOR
VICTOR
81A/81B
81A/81B
81A/81B
81A/81B
Digital
Digital
Digital
Digital
Multimeter
Multimeter
Multimeter
Multimeter
Operation
Operation
Operation
Operation
Manual
Manual
Manual
Manual
一.General
.General
.General
.General
………………………………………………
………………………………………………
………………………………………………
………………………………………………
1
1
1
1
二.Open-Package
.Open-Package
.Open-Package
.Open-Package
Inspection
Inspection
Inspection
Inspection
……………………………
……………………………
……………………………
……………………………
1
1
1
1
三.
.
.
.
Safety
Safety
Safety
Safety
Note
Note
Note
Note
……………………………………………
……………………………………………
……………………………………………
……………………………………………
2
2
2
2
四.
.
.
.
Front
Front
Front
Front
Panel&
Panel&
Panel&
Panel&
Button
Button
Button
Button
Function
Function
Function
Function
Description
Description
Description
Description
…………
…………
…………
…………
4
4
4
4
五.
.
.
.
Other
Other
Other
Other
Functions
Functions
Functions
Functions
………………………………………
………………………………………
………………………………………
………………………………………
5
5
5
5
六.Property
.Property
.Property
.Property
………………………………………………
………………………………………………
………………………………………………
………………………………………………
5
5
5
5
七.Instrument
.Instrument
.Instrument
.Instrument
Maintenance
Maintenance
Maintenance
Maintenance
……………………………
……………………………
……………………………
……………………………
1
1
1
1
5
5
5
5
八.Fault
.Fault
.Fault
.Fault
Elimination
Elimination
Elimination
Elimination
……………………………………
……………………………………
……………………………………
……………………………………
1
1
1
1
6
6
6
6

1
一、
General
General
General
General
VICTOR 81A/B
is
a
steady performance, high security
3
1/2 digital
multimeter.
It
uses
LCD with
18.9mm
high figure
to make the
reading
clear.
The
digital
multimeter
has
the function of measuring
ACV, DCV,
ACA,
DCA,
Resistance,
Celsius
&
Fahrenheit
Temperature,
Diode, Continuity.
The
instrument also
has
the features of
Unit Symbol
Display,
Auto/Manual
Range
Selection,
Auto
Power
Offer
and
Alarm
Function.
It adopts
the
directly
driven
8
digits
microprocessor
and
dual-integral
A/D
converter,
which
provide the high
resolution,
high accuracy displaying
driver.
Because of
its
outstanding
functions
,
the instrument
is
an
excellent
tool
and most
suitabl e
for
lab,
factory,
maintenance
and
repair
users.
二、 Open-Package
Open-Package
Open-Package
Open-Package
Inspection
Inspection
Inspection
Inspection
Open the gift box and take out the instrument, carefully check the
following accessories. If any accessory is missed or damaged, please
contact the manufactory at once.
● Digital Multimeter 1PC
● Operation Manual 1PC
●
Test
Leads 1SET
● Temperature Probe(K Type Thermocouple)
(Only VICTOR81B) 1PC
● AAA (1.5V )7# Battery 2PCS
● Holster 1PC

2
三、
Safety
Safety
Safety
Safety
Note
Note
Note
Note
The instrument
is
designed according
to
IEC1010 standard (safety
standard issued by International Electro technical Committee). Please read
the following before operation.
1. Caution
to
avoid the electric shock when measuring voltage higher
than 36V DC, 25AC, current higher than 10mA, AC power line with
inductance load and AC power line during the power fluctuation.
2. Before measuring, should check if the function knob
is
set in the
correct range and make sure the test leads connect reliably, link up
correctly, and insulate properly
to
avoid the electric shock
3. It meets the requirements of the safety standard only
to
use the
instrument with the equipped test leads. If the test leads are broken,
should replace them by the same type and same electric specification
test leads.
4. Do not replace the inside fuse by the unconfirmed one. Only replace
it by the same type and specification fuse. Before replacement,
should keep the test leads off the tested point
to
make sure there
is
no
any signal at the input terminal.
5. Do not replace the inside batteries by the unconfirmed one. Only
replace them by the same type and specification batteries. Before
replacement, should keep the test leads off the tested point
to
make
sure there
is
no
any signal at the input terminal.
6. When measuring electricity,
do
not connect the body with the ground
directly, and
do
not touch the possible exposed metallic terminal,

3
output socket or lead clamp with ground potential. Usually use the
dry cloth, rubber overshoes, rubber cushion and other insulated
materials
to
keep the body isolated with the ground.
7. Do not store and use the instrument in high humility, high
temperature, combustible, explosive and strong magnetic places.
8. It
is
possible
to
damage the instrument and endanger the safety of the
users when measuring the voltage over the limit. The allowed
maximum voltage
is
printed on the front panel of the instrument,
do
not measure the value over the standard safety voltage,
do
not input
the range limit specified
to
void the electric shock and instrument
damage.
9. Do not measure any voltage when connecting the test leads with the
current terminal
to
avoid damaging the instrument and endangering
the safety of the users.
10. Do not try
to
calibrate or repair the instrument, should operate it by
the specially trained or qualified professional people.
11. The function/range selection knob should be set in the correct range
when measuring. When switching the function/range selection knob,
keep the test leads off the tested object
to
make sure there
is
no
any
signal at the input terminal. Do not switch the f unction/range
selection knob when measuring.
12. When LCD displays “ ”
,
please replace the batteries in time
to
make sure the measuring accuracy.
13. Do not allow
to
measure the voltage when connecting the test leads
with the current terminal!

4
14. Do not try
to
modify the inner circuit at will
to
avoid damaging the
instrument and endangering the safety of the users.
15 .
Safety Symbol Description
:
四、
Front
Front
Front
Front
Panel
Panel
Panel
Panel
&
&
&
&
Button
Button
Button
Button
Function
Function
Function
Function
Description
Description
Description
Description
1. Instrument Model Number
2.LCD Display :Display the measured data and unit.
3.Function Button
3.1.MAX (Max
Value
Hold
)
: Press the button, the reading
is
renewe d
and the max value
is
held on LCD.
3.2.SELECT (Function Switch
) :
Press the button, DC/AC mode,
/ , ℃/℉performance switch.
3.3.HOLD
(Data Hold
) :
Press the button, the reading
is
locked, press t he
button again, the lock
is
cleared.
3.4.RANGE (Auto/Manual Range Switch ): Auto Range
is
the original
states, press the button
to
switch
to
the Manual Range. At the Manual
Warning!
Warning!
Warning!
Warning!
DCA
DCA
DCA
DCA
High
High
High
High
Voltage
Voltage
Voltage
Voltage
!
!
!
!
Dangerous!
Dangerous!
Dangerous!
Dangerous!
ACA
ACA
ACA
ACA
GND
GND
GND
GND
DCA
DCA
DCA
DCA
&
&
&
&
ACA
ACA
ACA
ACA
Dual
Dual
Dual
Dual
Insulation
Insulation
Insulation
Insulation
Meets
Meets
Meets
Meets
the
the
the
the
direction
direction
direction
direction
of
of
of
of
European
European
European
European
IEC
IEC
IEC
IEC
Low
Low
Low
Low
Battery
Battery
Battery
Battery
Fuse
Fuse
Fuse
Fuse

5
Range mode, press the button once, the range
is
switched
to
the higher
one, press the button again
to
switch the range
to
the lowest one when
measuring the highest range, the cycle
is
in proper order from low
to
high. Keep pressing the button for 2 sec., return
to
Auto Range mode.
4.Knob Switch :Change the measuring
function and range 。
5.Input Terminals
5.1.Current 、V oltage 、Diode 、
Resistance 、Buzzer 、
Temperature “ - ” Input terminal.
5.2.10A “ + ” input terminal.
5.3.V oltage 、Diode 、Resistance 、
Buzzer 、Temperature and Current
less than 200mA “ + ” input terminal.
五、 Other
Other
Other
Other
Functions
Functions
Functions
Functions
Stop working for 15 seconds during measurement, the instrument will be
auto power off (sleeping mode)
to
save the power; in the auto power offer
mode, press any function button or change the knob switch, the instrument
will get into the auto power on mode (working mode); the auto power offer
mode will be cancelled by pressing the HOLD button
to
turn on the
instrument.
六、
Property
Property
Property
Property
1
1
1
1
.
General
General
General
General
Property
Property
Property
Property
1-1 .
Display
:LCD
1-2 .Max
Display
:1999 (3 1/2 )
counts
automatic polarity display
and
unit
display

6
1-3 .Measuring Method :
Dual integral
A/D converter
1-4 .
Sampling
Rage :
Approx.
3
times
/
sec.
1-5 .
Over range Indication
:
Display
“ OL ”
1-6 .
Low Battery Indication
:“ ”
symbol
appearance
;
1-7 .
Operation
Environment
: (
0~40 ) ℃ ,
Relative
Humidity: <80% ;
1-8 .
Storage
Environment
: (
0~50 )℃,
Relative
Humidity: <80% ;
1-9 .Power :
2pcs
1.5V
batteries
(“ AAA ” 7#
battery
) ;
1-10 .Dimension (size
) :
145 × 74 ×
36mm
1-11
.
Weight
:
Approx.
185g (
Including
2pcs
1.5Vbatteries
)
1-12
.
Accessories
:
1pc
operation
manual
,
Holster
、
1pc
gift
box
,
1
set
10A
lest
leads
、1pc
K
Type
Temperature
Probe
TP01
(only
VICTOR81B) and
2pcs
1.5
batteries
。
2
2
2
2
.
T echnical
T echnical
T echnical
T echnical
Property
Property
Property
Property
2-1 .
Accuracy:
± (% ×
reading
+
digits)
,
at
(23 ± 5) ℃ ,
relative
humidity <75%
,
One
year
calibration
guarantee since the time dispatched
from
the
factory.
。
2-2 .
Performance
(note “▲”
indicates
the instrument
has
the function
)
Model
Function
VICTOR81A
VICTOR81B
DCV
▲
▲
ACV
▲
▲
DCA
▲
▲
ACA
▲
▲
Ω
▲
▲
Diode/Continuity
▲
▲
Celsius/Fahrenheit ℃/℉
*
▲

7
2-3.Technic Specification (note “ * ” indicates the instrument does not have
the range)
2-3-1.DCV
2-3-1.DCV
2-3-1.DCV
2-3-1.DCV
1.
Insert
the red
and
black
test
leads
separately
to
and COM
input
mA
mA
mA
mA
V
V
V
V
terminals.
2.
Turn
the
knob
switch
to
Range,
press
“ SELECT ”
button
to
switch
to
DCV
measurement
mode.
3.
This range
is
200mV,
The reading
to
measure the voltage less than
200mV
is
much accurate and stable than the reading measured in the
Range “ ” .
4.
Turn the knob switch
to
“”Range.
5.
Auto range mode
is
the original states, it displays “ AUTO ” symbol, Press
“ RANGE ” button
to
switch
to
Manual range mode, can select 200mV
、
2V 、20V 、200V 、600V Range.
6.
Connect the test leads
to
the tested point, the voltage and polarity of
point connected by red lead will be displayed on LCD.
Note
Note
Note
Note
:
1.
At the Manual Range mode, if “ OL ”
is
displayed on LCD, it indicates the
tested voltage value has exceeded the present range limit, please select
the higher range
to
complete the measurement.
2.
Do not measure the voltage higher than
600V.
Otherwise, there
is
the
danger
to
damage the instrument.
3.
When measuring the high voltage, caution
to
avoid the body touches the
high voltage.

8
Input Impedance :>10M Ω at Range 200mV
,
40M Ω at other Ranges 。
Overload Protection :600V AC or 600V AC Peak Value ;
2-3-2.
2-3-2.
2-3-2.
2-3-2.
ACV
ACV
ACV
ACV
1. Insert
the red
and
black
test leads
separately
to
and COM
input
mA
mA
mA
mA
V
V
V
V
terminals.
2.
Turn
the
knob
switch
to
Range,
press
“ SELECT ”
button
to
switch
to
ACV measurement
mode.
3.
This range
is
200mV,
The reading
to
measure the voltage less than
200mV
is
much accurate and stable than the reading measured in the
Range “ ” .
4.Turn the knob switch
to
“”Range.
5.Auto range mode
is
the original states, it displays “ AUTO ” symbol,
Press “ RANGE ” button
to
switch
to
Manual range mode, can select
200mV 、2V 、20V 、200V 、600V Range.
6.Connect the test leads
to
the tested point, the voltage and polarity of
point connected by red lead will be displayed on LCD.
Note
Note
Note
Note
:
1.
At the Manual Range mode, if “ OL ”
is
displayed on LCD, it indicates the
Accuracy
Range
VICTOR81A
VICTOR81B
Resolution
200mV
± (0.5%+4d)
100uV
2V
1mV
20V
10mV
200V
100m A
600V
± (1.0%+4d)
1V

9
tested voltage value has exceeded the present range limit, please select
the higher range
to
complete the measurement.
2.
Do not measure the voltage higher than
600V.
Otherwise, there
is
the
danger
to
damage the instrument.
3.
When measuring the high voltage, caution
to
avoid the body touches the
high voltage.
Input Impedance :>10M Ω at Range
200mV,
40M Ω at other ranges 。
Overload Protection :600V DC or 600V AC Peak Value ;
Frequency Response
: (
50 ~200 )Hz
Display :Average value response (RMS of sine wave) .
2-3-3.
2-3-3.
2-3-3.
2-3-3.
DCA
DCA
DCA
DCA
1.
Insert
the
black
test
lead
to
the
COM
input
terminal,
and
red
test
lead
to
mA
mA
mA
mA
V
V
V
V
input
terminal
(max 200 mV
)
or
10A
input
terminal
(max 10A).
2.
Turn
the
knob
switch
to
Current
Range,
press
“ SELECT ”
button
to
switch
to
DCA
measurement
mode.
Connect the test leads
to
the tested point in
series, the current value and polarity of point connected by red lead will
be displayed on LCD simultaneously.
3.
Press “ RANGE ” button
to
select auto or manual range mode.
Accuracy
Range
VICTOR81A
VICTOR81B
Resolution
200mV
± (1.5%+20d)
100uV
2V
± (0.8%+6d)
1mV
20V
10mV
200V
100mV
600V
± ( 1.0 %+6d)
1V

10
Note
Note
Note
Note
:
1.
Firstly users should select the auto range mode, if users had
no
idea
about the range of tested current, and then select the proper range based
on displaying value.
2.
If “ OL ”
is
displayed on LCD, it indicates the tested current value has
exceeded the present range limit, please select the higher range
to
complete the measurement.
3.
Max input value
is
200mA or 10A (Depending on the terminal the red
test lead
is
inserted ).
The input value
is
exceeding the range limit, the fuse will be melt, even
damage the instrument.
Max measurement voltage drop :Full Range mA
is
1.2V ,
A is
100mV ;
Max input current :10A (less than 15 seconds
) ;
Overload Protection :0.2A/250V restorable fuse ,10A/250V fuse.
2-3-4.
2-3-4.
2-3-4.
2-3-4.
ACA
ACA
ACA
ACA
1.
Insert
the
black
test
lead
to
the
COM
input
terminal,
and
red
test
lead
to
mA
mA
mA
mA
V
V
V
V
input
terminal
(max 200 mV
)
or
10A
input
terminal
(max 10A).
2.
Turn
the
knob
switch
to
Current
Range,
press
“ SELECT ”
button
to
switch
to
Accuracy
Range
VICTOR81A
VICTOR81B
Resolution
200uA
± ( 1.0 %+ 10 d)
0.1uA
2000uA
1uA
20mA
10uA
200mA
100uA
10A
± (1. 2 %+1 0 d)
10mA

11
ACA measurement
mode.
Connect the test leads
to
the tested point in
series, the current value and polarity of point connected by red lead will
be displayed on LCD simultaneously.
3.
Press “ RANGE ” button
to
select auto or manual range mode.
Note
Note
Note
Note
:
1.
Firstly users should select the auto range mode, if users had
no
idea
about the range of tested current, and then select the proper range based
on displaying value.
2.
If “ OL ”
is
displayed on LCD, it indicates the tested current value has
exceeded the present range limit, please select the higher range
to
complete the measurement.
3.
Max input value
is
200mA or 10A (Depending on the terminal the red
test lead
is
inserted ).
The input value
is
exceeding the range limit, the fuse will be melt, even
damage the instrument.
Max measurement voltage drop :Full Range mA
is
1.2V ,
A is
100mV ;
Max input current :10A (less than 15 seconds
) ;
Overload Protection :0.2A/250V restorable fuse ,10A/250V fuse.
Accuracy
Range
VICTOR81A
VICTOR81B
Resolution
200uA
± (1. 5 %+ 10 d)
0.1uA
2000uA
1uA
20mA
10uA
200mA
100uA
10A
± ( 2 .5%+15d)
10mA

12
Frequency Response :10A Range (50 ~200)Hz ,
2-3-5.Resistance
2-3-5.Resistance
2-3-5.Resistance
2-3-5.Resistance
(Ω
Ω
Ω
Ω
)
1. Insert
the red
and
black
test leads
separately
to
and COM
input
mA
mA
mA
mA
V
V
V
V
terminals.
2.
Turn
the
knob
switch
to
“Ω
Ω
Ω
Ω
”
Range,
connect the
test leads cross
with the
tested
resistor.
3.
Press “ RANGE ” button
to
select auto or manual range mode.
4.
When
measuring the
min.
resistance
,
please short-circuit
the
test leads
at
first
to
test
the wire
resistance,
and
then deduct
it
from
the
actual
resistance.
Note
Note
Note
Note
:
1.
Firstly users should select the auto range mode, if users had
no
idea
about the range of tested current, and then select the proper range based
on displaying value.
2.
If “ OL ”
is
displayed on LCD, it indicates the tested resistance value has
exceeded the present range limit, please select the higher range
to
complete the measurement. When measuring the Resistor higher than
1M Ω
,
the instrument will take several seconds
to
make the reading
stable, it
is
normal when measuring the high resistor.
3.When the input terminal
is
open circuit, it will display “ OL ” .
4.
When measuring in line resistor, be sure that the power
is
off and
all
capacitors are released completely.

13
Open
Voltage
circuit :Less than 200mV ;
Overload Protection :250V DC or AC Peak Value ;
Note :When measuring at Range 200 Ω
,
please
short-circuit
the
test leads
at
first
to
test
the wire
resistance,
and
then deduct
it
from
the
actual
resistance.
2-3-6.Diode
2-3-6.Diode
2-3-6.Diode
2-3-6.Diode
and
and
and
and
Continuity
Continuity
Continuity
Continuity
Test
Test
Test
Test
1. Insert
the
black test
lead
to
“ COM ”
terminal
and
the red
test
lead
to
“ ”mA
mA
mA
mA
V
V
V
V
terminal
(the polarity of red lead
is
“ + ”
)
2.
Turn the knob
to
range ,press “ SELECT ” button
to
select the
Diode measurement mode.
3.
Forward Measurement: connect test leads with the diode under tested,
the red test lead connect
to
diode positive polarity, the black test lead
to
diode cathode polarity, the reading
is
the approx. value of diode forward
volt drop .
4.
Backward Measurement: the red test connect
to
diode positive polarity,
the black test lead
to
diode cathode polarity ,the LCD displays “ OL ” .
5.
The complete diode testing includes forward and backward
measurement, if the result isn ’ t meet the above, it means the diode
is
bad.
Accuracy
Range
VICTOR81
A
VICTOR8 1
B
Resolutio
n
200 Ω
± (0.8%+5d)
0.1 Ω
2k Ω
± (0.8%+4d)
1 Ω
20k Ω
10 Ω
200k Ω
100 Ω
2M Ω
1k Ω
20M Ω
± (1.2%+ 10 d)
10k Ω

14
6.
Press “ SELECT ” button
to
select the Continuity measurement mode.
7.
Insert test leads
to
two points of tested circuit, if the inner buzzer sounds,
the resistance
is
less than 50 Ω .
Overload Protection: 250V DC or AC Peak Value.
CAUTION :DO NOT INPUT VOLTAGE
AT
THIS RANGE!
2-3-7.Celsius/Fahrenheit( ℃/℉)(Only VICTOR81B)
1.
Switch the knob to “ ℃/℉” range, press “ SELECT ” button
to
switch
to
“℃” and “ ℉” measurement mode.
2.
Insert the cathode(black pin) of cold end (free end) of thermocouple into
“ COM ” jack, anode (red pin) into “ ” terminal, put the working endmA
mA
mA
mA
V
V
V
V
(temperature measurement end) of thermocouple on the surface or inside
the object
to
be tested. Then you can read temperature from the screen,
and the data
is
in Centigrade.
Note
Note
Note
Note
:
1.
When the input terminal open-circuit ,it will display the normal
temperature.
2.
Don ’ t change the temperature probe optionally ,or the value accuracy
isn ’ t guarantee.
3.
Don ’ t input voltage at temperature range.
Range
Display
Test
Condition
Forward V oltage Drop of
Diode
Forward DC Current is
Approx. 0.5mA ,
Backward
Voltage
is
Approx. 1.5V
Buzzer makes a long
sound while resistance is
less than 50 Ω
Open circuit voltage is
Approx. 0.5V

15
Sensor :K Type Thermocouple (banana plug) 。
CAUTION :DO NOT INPUT VOLTAGE
AT
THIS RANGE!
七、 Instrument
Instrument
Instrument
Instrument
Maintenance
Maintenance
Maintenance
Maintenance
I
nstrument
is
a high accuracy instrument, please don ’ t modify the circuit.
1.Keep the instrument away from water, dust and shock.
2.Do not store and operate the meter under the condition of high
temperature, high humidity, combustible, explosive and strong
magnetic place.
3
.
Wipe the case with a damp cloth and detergent,
do
not use abrasives an d
alcohol.
4.
If
do
not operate for a long time, should take out the battery
to
avoid
leakage.
5.When ” ” symbol displays, should replace the battery following the
steps:
5-1 .Unlock the screw and remove the battery case;
5-2 .Take out the old battery and replace the new one. It's better
to
use
alkaline battery for longer life.
5-3 .Fit on the battery case and lock the screw.
Note
Note
Note
Note
:
1.
Don ’ t input the voltage value higher than DC 1000V or AC Peak Value.
Accuracy
Range
Accuracy
Resolution
(-20 ~1000) ℃
<400 ℃± (1.0%+5d)
≥ 400 ℃± (1.5%+15d)
1℃
(0~1832 ) ℉
± (1.5%+15d)
1℉

16
2.
Don ’ t measuring the voltage at current, resistance, diode and continuity
range.
3.Don ’ t use the instrument when the battery isn ’ t installed or the back case
isn ’ t firm.
4.
When replacing battery or fuse, please take away the test leads from the
measured point and power off at first.
八、 Fault
Fault
Fault
Fault
Elimination
Elimination
Elimination
Elimination
If the instrument does not work properly, check the instrument
as
following:
The
The
The
The
specifications
specifications
specifications
specifications
are
are
are
are
subject
subject
subject
subject
to
to
to
to
change
change
change
change
without
without
without
without
notice.
notice.
notice.
notice.
The
The
The
The
content
content
content
content
of
of
of
of
this
this
this
this
manual
manual
manual
manual
is
is
is
is
regarded
regarded
regarded
regarded
as
as
as
as
correct,
correct,
correct,
correct,
error
error
error
error
or
or
or
or
omits
omits
omits
omits
Pls.
Pls.
Pls.
Pls.
contact
contact
contact
contact
with
with
with
with
factory.
factory.
factory.
factory.
We
We
We
We
hereby
hereby
hereby
hereby
will
will
will
will
not
not
not
not
be
be
be
be
responsible
responsible
responsible
responsible
for
for
for
for
the
the
the
the
accident
accident
accident
accident
and
and
and
and
damage
damage
damage
damage
caused
caused
caused
caused
by
by
by
by
improper
improper
improper
improper
operation
operation
operation
operation
.
.
.
.
The
The
The
The
function
function
function
function
stated
stated
stated
stated
for
for
for
for
this
this
this
this
operation
operation
operation
operation
manual
manual
manual
manual
cannot
cannot
cannot
cannot
be
be
be
be
the
the
the
the
reason
reason
reason
reason
of
of
of
of
special
special
special
special
usage.
usage.
usage.
usage.
Fault
Solution
No Display
● Turn on power ;
● Replace battery.
symbol
appearance
● Replace battery.
Big error value
● Replace battery.
This manual suits for next models
1
Table of contents
Other Victor Multimeter manuals

Victor
Victor 81D User manual

Victor
Victor VC9808 User manual

Victor
Victor 8155 User manual

Victor
Victor 88C User manual

Victor
Victor 70D User manual

Victor
Victor VC9807A+ User manual

Victor
Victor 6000counts User manual

Victor
Victor VC9806+ User manual

Victor
Victor 98A User manual

Victor
Victor VC9808+ User manual

Victor
Victor 86B Parts list manual

Victor
Victor VC88E User manual

Victor
Victor 81D User manual

Victor
Victor VC890D User manual

Victor
Victor VC97 User manual

Victor
Victor VC9808plus User manual

Victor
Victor VC890D User manual

Victor
Victor 6056B User manual

Victor
Victor VR-9807A User manual

Victor
Victor VC830L User manual