manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Victron energy
  6. •
  7. Control Panel
  8. •
  9. Victron energy Blue Power BMV-602 User manual

Victron energy Blue Power BMV-602 User manual

Other manuals for Blue Power BMV-602

2

Other Victron energy Control Panel manuals

Victron energy Color Control GX User manual

Victron energy

Victron energy Color Control GX User manual

Victron energy VE.Net Blue Power Panel User manual

Victron energy

Victron energy VE.Net Blue Power Panel User manual

Victron energy VE.Bus User manual

Victron energy

Victron energy VE.Bus User manual

Victron energy Color Control GX User manual

Victron energy

Victron energy Color Control GX User manual

Victron energy CCGX User manual

Victron energy

Victron energy CCGX User manual

Victron energy Skylla-i Control GX User manual

Victron energy

Victron energy Skylla-i Control GX User manual

Victron energy Color Control GX User manual

Victron energy

Victron energy Color Control GX User manual

Victron energy Digital Multi Control User manual

Victron energy

Victron energy Digital Multi Control User manual

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

NAPCO X 255 - Programming instructions

NAPCO

NAPCO X 255 - Programming instructions

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Instructions for the Victron Energy MONITORING PANEL with
DIGITAL MULTI CONTROL PANEL (DMC) and
BATTERY MONITOR BMV-602
This publication or parts thereof, may not be reproduced in any form, by any method, for any
purpose. For conditions of use and permission to use this manual for publication in other
than the English language, conctat Victron Energy B.V.
Victron Energy B.V. reserves the right to revise and improve its products as it sees fit. This
publication describes the state of this product at time of its publication and may not reflect at
all times in the future.
Introduction
The MONITORING PANEL with integratet Digital Multi Control Panel and Battery Monitor
BMV - 602 is a device that:
•Monitors your battery status (battery voltage and current) and calculate the actual
state of charge of your battery
•Monitors and signals AC voltage of three sources (shore, generator and inverter)
•Monitors inverter current to the AC consumer
•is a remote panel designed to work with all Multis/Quatro¨s and Multi/Quatro systems.
Operation
Installation
•WARNING! Be sure that all AC power sources are switched off or disconnected
during installation.
•Install the MONITORING PANEL in a dry, well ventilated area. The front of the panel
is attached using the four supplied screws. The MONITORING PANEL may be
mounted in the wall, using the four holes in the front of the panel.
•The input cables from the shore, generator, inverter, digital multi control and battery
monitor should be connected according to the the wiring diagram (see figure 1). The
correct wire cross section must be applied for a safe installation. Under sized cables
can cause overheating of the cables.
•Tighten all connections well in order to limit transition resistance as far as possible.
Loose connections can cause dangerous overheating of the teminals.
•Adjustement of the MONITORING PANEL ist not recommended. After correct
instalation the MONITORING PANEL is ready for use.
2
•The wiring to the AC-inputs and outputs must be protected by fuses or miniature
circuits breaker which are suitable for the applied wire cross section. External earth
leakage switches( RCD, RCCB) must also be integrated in the wiring
•All ground connections of the power sources and power consumers must be
connected to the central ground connection of the ship
•To connect Digital Multi control panel see user and installation manual
•To connect Battery monitor BMV-602 see user and installation manual
Transport and storage
•When storing or transporting the product , make certain that mains power and battery
leads are disconnected
•No liability can be accepted for any transport damage when equipment is shipped in
non-original packaging
•Store the product in a dry location, storage temperature must be between - 20
°
°°
°
C and
+ 60
°
°°
°
C.
•
3
Specifications
VE
MONITORING PANEL
Nominal voltage
200
-
250 V AC
, Single phase
Nominal frequency
50
–
60 Hz
Input 1, Shore voltage
200
-
250 V, AC
Input 2, Generator voltage
200
-
250 V, AC
Input 3, Inverter output voltage
200
-
250 V AC
Current transformer (CT)
50/5 A,
2
VA
Power supply
12 V, DC
GENERAL
Operating temperature -5
°
°°
°
C to + 60
°
°°
°
C
Humidity (non condensing)
Max. 95 %
Miniatur circuit breaker (MCB)
Not included
–
installation dependent
Earth leakage breakers (RCD)
Not included
–
installation dependent
ENCLOSURE
Protection category
IP
20
Color
RAL 7035
Dimension h x w x d (mm)
213
x
150
x
75
Weight (kg)
0,985
Contents:
- Monitoring panel 1 piece
- Power supply cable, 1,2 m 1 piece
- Current transformer 50/5 A 1 piece
- CT cable, 10 m 1 piece
- Input 1,2, 3, cable, 1,2 m 1 piece
4
Electrical and installation diagrams, outline drawings
5
MONITORING PANEL wiring with MULTI PLUS
6
MONITORING PANEL wiring with QUATTRO
7