Meaning of the rating plate fields
1Model and length of the refrigerated cabinet
2Serial number, code and/or configuration number (if any)
3Year of manufacture
4
Climate class, it gives the proper environmental conditions in which the unit operates properly
3 – The unit is suitable for operating in an environmental temperature of 2 ° C and a relative humidity of 60%
4 – The unit is suitable for operating in an environmental temperature of 30° C and a relative humidity of %
Temperature class of the unit; it indicates the category of the products that can be preserved in the refrigerated
cabinet:
L1: suitable for the preservation of frozen food or ice-cream
M0: suitable for the preservation of fresh products such as meat and poultry
M1: suitable for the preservation of fresh products such as meat and poultry
M2: suitable for the preservation of fresh products such as salami and dairy products
H: suitable for the preservation of fresh products such as fruit and vegetables
S: suitable for the preservation of products with a special classification
6
Maximum power absorbed by the unit, with all required accessories installed, operating in the temperature
class for which the units were built (given by the temperature class)
7
Power absorbed during defrost; includes the electric heater (if present) and all the other electric devices operat-
ing during the defrost cycle, such as controllers, fan motors, lighting etc.
8Rated supply voltage, number of phases and frequency to which the cabinet must operate.
9Electrical power absorbed, rated voltage and current of other installed electric devices (if any).
10 Electrical power absorbed, rated voltage and current of the defrost heaters (if any)
11 Electrical power absorbed, rated voltage and current of the demisting heaters (if any)
13 Type and quantity of used refrigerant
14 It indicates the kind of lamination device. CT = capillary tube. TVX = thermostatic valve
1 Net volume of the additional refrigerant storage (if any)
16 Refrigerated display area available to display the goods
17 Maximum operating pressure inside the refrigeration circuit of the unit
18 Rated current absorbed by the unit in normal operating conditions
19 Rated current absorbed by the unit at the compressor starting phase (starting current)
20 Model of condensing unit or compressor installed
21 Electrical power absorbed, rated voltage and current of the lighting system (if any)
22 Electrical power absorbed, rated voltage and current of the fan motors (if any)
23 Electrical power absorbed, rated voltage and current of the condensing unit
12 ID name in the EPREL database
3. Rating plate