Flat plate solar collectors for the harnessing of solar energy
Panels with 25 ft.
2
(2.32 m
2
) absorber surface
Technical Data Manual
Part Nos. and Pricing: see Price List
V
VV
VI
II
IT
TT
TO
OO
OS
SS
SO
OO
OL
LL
L 2
22
20
00
00
00
0-
--
-F
FF
FModel SV2A and SH2A
Flat plate solar collectors
for vertical or hori ontal installation
on sloped and flat roofs
To produce domestic hot water, or to supplement
low-temperature heating systems or swimming pools
via a heat exchanger
Listed by CSA International as complying
with the Energy Efficiency Verification
Service requirements
Certified in accordance with SRCC OG-100.
Meets the requirements of the German “Blue Angel”
certificate of environmental excellence to RAL UZ 73.
Certified in accordance with Solar Keymark testing
requirements.
5285 622 v2.2 03/2011
Product Information
2
Vitosol 200-F
Models SV2A,SH2A
The benefits at a glance:
HHigh perfor ance, premium version flat
plate collector, thanks to unique frame
design and quality components.
HSuitable for any residential or co ercial
applications with vertical or hori ontal
versions available. Suitable for DHW or
pool heating, space heating and cooling
applications.
HAttractive appearance with powder coated
brown frame, endless glass seal and
minimal space between collectors. No
screws or rivets used in frame for clean,
neat finish.
HRugged, high-quality construction using
impact-resistant low-iron solar glass,
copper piping, aluminum absorber and
frame and non-degrading thermal insulation.
HPer anently sealed and high stability
through all-around folded aluminum frame
and endless glass seal. No screws or
rivets penetrate frame.
HUniversal application on flat and sloped
roofs, or freestanding, vertical or
hori ontal installations, connect up to 12
collectors in one array for commercial or
residential systems.
HFast installation with flexible connection
pipes and quick-connect fittings.
Prefabricated collector mounting hardware
ensures easy connection to roofs.
HMaxi u syste perfor ance and
reliability with a full range of solar system
components designed to integrate
seamlessly.
HCertified to the Solar Rating and Certification
Corporation (SRCC) OG-100 Standard.
CSA Energy Efficiency Verification.
HQuality tested to Solar Keymark testing
requirements. Meets the requirements of
the German “Blue Angel” certificate of
environmental excellence.
Solar glass cover, 0.13” (3.2 mm) thick
Aluminum cover strip
Continuous flexible glass seal
Highly selective coated aluminum
absorber sheet
Meander-shaped copper pipe
Construction and function
The main component of the Vitosol 200-F
is the blue surface highly selective coated
aluminum absorber. It ensures high absorption
of solar radiation and low emission of
thermal radiation. A meander-shaped copper
pipe, through which the heat transfer
medium flows, is permanently embedded
into the absorber.
The heat transfer medium channels the
absorber heat through the copper pipe.
The absorber is encased in a highly insulated
collector housing, which minimi es collector
heat losses. The high quality thermal
insulation provides temperature stability
and is free from gas emissions.
The cover consists of a solar glass panel
with a very low iron content, thereby
reducing reflection losses. The solar glass
is 3.2 mm thick, making it very resistant to
weather influences.
Melamine resin foam insulation
Melamine resin foam insulation
Aluminum frame sections
Aluminum- inc coated sheet steel
back panel
The glass is set into the collector frame with
a continuous profiled seal, preventing water
from penetrating into the collector. This
ensures a long and reliable service life for
all internal components.
The collector housing consists of a
powder-coated aluminum frame (one piece)
into which the solar glass is permanently
sealed.
Up to twelve collectors can be joined quickly
and easily to form a single collector array.
For this, the standard equipment includes
flexible connection pipes, sealed with
O-rings (see picture below).
A connection kit with clamping ring fittings
enables the collector array to be quickly
connected to the pipes of the solar circuit.
The collector temperature sensor is installed in
the solar circuit flow using a sensor well set.
Flexible interconnection pipes
5285 622 v2.2
Technical Data
3
Technical Data
Model - Vitosol 200-F SV2A SH2A
Total surface area ft.
2
(m
2
) 27.0 (2.51) 27.0 (2.51)
Absorber surface area ft.
2
(m
2
) 25.0 (2.32) 25.0 (2.32)
Aperture
*1
ft.
2
(m
2
) 25.1 (2.33) 25.1 (2.33)
Di ensions
*2
Width
Height
Depth
inches
mm
inches
mm
inches
mm
41¾
1056
93¾
2380
3½
90
93¾
2380
41¾
1056
3½
90
Optical efficiency
*3
% 79.3 79.3
Heat loss coefficient U
1
Heat loss coefficient U
2
W/(m
2.
K)
W/(m
2.
K
2
)
4.04
0.0182
4.04
0.0182
Ther al capacity kJ(m
2.
K) 5.0 5.0
Weight lb (kg) 90.2 (40.9) 90.2 (40.9)
Fluid capacity
(heat transfer ediu )
USG
L
0.48
1.83
0.65
2.48
Maxi u working pressure
*4
psig
bar
87
6
87
6
Maxi u stagnation te perature
*5
ºF (ºC) 367 (186) 367 (186)
Connection inches
mm
¾
22
¾
22
Require ents for installation surface and
anchorage
Roof construction with adequate load capacity for prevailing wind forces
*1
Important for system design considerations.
*2
Dimensions rounded to the nearest ¼ inch.
*3
ased on absorber surface area.
*4
In sealed systems, operating pressure of at least 15 psig + 0.45 psig x static head (ft.) / 1.0 bar + 0.1 bar x static head (m) must be
present in the collectors in cold condition.
*5
The stagnation temperature is the temperature which applies to the hottest point of the collector at a global radiation intensity of
3412 tu/h / 1000 W when no heat is conducted by the heat transfer medium.
5285 622 v2.2
CR
CS
41¾”/1056 mm
93¾”/2380 mm
86½”/2200 mm
3½”
90 mm
3½”/ 90 mm
2”
51 mm
Model SV2A
CS
CR
Model SH2A
41¾”/1056 mm
93¾”/2380 mm
34½”/876 mm
3½”
90 mm
3½”/ 90 mm
2”
51 mm
Legend
CR Collector return (inlet)
CS Collector supply (outlet)
Standard Equipment/Accessories
Viessmann Manufacturing Company Inc.
750 McMurray Road
Waterloo, Ontario •N2V 2G5 •Canada
Tel. (519) 885-6300 •Fax (519) 885-0887
www.viessmann.ca •info@viessmann.ca
Viessmann Manufacturing Company (U.S.) Inc.
45 Access Road
Warwick, Rhode Island •02886 •USA
Tel. (401) 732-0667 •Fax (401) 732-0590
www.viessmann-us.com •info@viessmann-us.com
4
Heat transfer ediu
Tyfocor non-toxic heating liquid for solar
heating systems with active anti-corrosion
and anti-ageing protection.
Frost protection: to -31ºF (-35ºC)
Specific gravity
at 68ºF (20ºC): 1.032 to 1.035 g/cm
3
to ASTM D 1122
Viscosity
at 68ºF (20ºC): 6.5 to 8.0 mm
2
/s
to DIN 51562
pH value: 7.5 to 8.5
to ASTM D 1287
Color: transparent,
blue-green
Container: 5.3 USG (20 L) in a
disposable container
Standard equip ent
Vitosol 200-F, Models SH2A and SV2A
come fully assembled in shrink-wrap
packaging and ready to be connected.
Accessories
Accessories (individually packed, depending
on order):
- Mounting hardware with technical
literature
- Interconnection pipes with insulation
- General connection set
- Sensor well set
- Solar Divicon (pumping station for the
collector circuit)
- Automatic air vent with air separator
- Fast air vent valve with tee and
shutoff valve
- System filling manifold
- Solar hand pump
- Solar expansion tank
- Heat transfer medium
Mounting hardware
The mounting hardware consists of
components required for the relevant
method of installation, such as:
Roof brackets, mounting plates, mounting
rails, connecting elements for mounting
rails, clamping bolts, screws and nuts.
General connection set
Required to connect solar collector to
system piping. One set required per collector
array - max. 269 ft
2
(25 m
2)
.
Part No. 7248 240
Pipe connection set
Required to connect multiple solar
collectors.
Part No. 7248 239
x 2
Sloped roof hardware
Required for mounting collector directly onto
shingled roof. Raises collector 3½”
(889 mm) above the roof.
Roof bracket
Installation rail
Flat roof hardware
Required for freestanding, flat roof
installations.
Solar Divicon
Preassembled pumping station for solar
collector circuit.
Includes: 3-speed pump (2 si es), pressure
gage, 2 thermometers, 2 ball valves,
pressure relief valve, flow meter, 2
flowcheck valves, air separator, system fill
manifold, and foam insulation cover.
Part No. 7134 799 (for DN20)
7134 800 (for DN25)
SCU 124/224
Electronic differential temperature control
for solar heating.
Please note
Viessmann offers complete solar heating
system combi packages, as well as
comprehensive design support in order to
facilitate the component selection process.
5285 622 v2.2 Printed on environmentally friendly
(recycled and recyclable) paper.
T
e
c
h
n
i
c
a
l
i
n
f
o
r
m
a
t
i
o
n
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
w
i
t
h
o
u
t
n
o
t
i
c
e
.

Other manuals for VITOSOL 200-F

7

This manual suits for next models

2

Other Viessmann Solar Panel manuals

Viessmann VITOSOL-F User manual

Viessmann

Viessmann VITOSOL-F User manual

Viessmann Vitosol 300-T User manual

Viessmann

Viessmann Vitosol 300-T User manual

Viessmann VITOSOL 100-F SV1 Instruction manual

Viessmann

Viessmann VITOSOL 100-F SV1 Instruction manual

Viessmann Vitosol-F Type SV User manual

Viessmann

Viessmann Vitosol-F Type SV User manual

Viessmann Vitosol-T Operating instructions

Viessmann

Viessmann Vitosol-T Operating instructions

Viessmann Vitosol 300-T User manual

Viessmann

Viessmann Vitosol 300-T User manual

Viessmann Vitosol 100 User manual

Viessmann

Viessmann Vitosol 100 User manual

Viessmann VITOSOL-F User manual

Viessmann

Viessmann VITOSOL-F User manual

Viessmann VITOSOL-F Operating instructions

Viessmann

Viessmann VITOSOL-F Operating instructions

Viessmann VITOSOL-F Operating instructions

Viessmann

Viessmann VITOSOL-F Operating instructions

Viessmann Vitosol 222-T Operating instructions

Viessmann

Viessmann Vitosol 222-T Operating instructions

Viessmann Vitovolt 200 Operating instructions

Viessmann

Viessmann Vitovolt 200 Operating instructions

Viessmann VITOSOL 100-F SV1B Instruction manual

Viessmann

Viessmann VITOSOL 100-F SV1B Instruction manual

Viessmann VITOVOLT 200 5458 User manual

Viessmann

Viessmann VITOVOLT 200 5458 User manual

Viessmann Vitosol 200-T User manual

Viessmann

Viessmann Vitosol 200-T User manual

Viessmann Vitovolt 300 User manual

Viessmann

Viessmann Vitovolt 300 User manual

Viessmann VITOSOL SERIES User manual

Viessmann

Viessmann VITOSOL SERIES User manual

Viessmann Vitosol 200-T User manual

Viessmann

Viessmann Vitosol 200-T User manual

Viessmann VITOSOL 200-F User manual

Viessmann

Viessmann VITOSOL 200-F User manual

Viessmann VITOSOL-F User manual

Viessmann

Viessmann VITOSOL-F User manual

Viessmann VITOSOL F User manual

Viessmann

Viessmann VITOSOL F User manual

Viessmann Vitosol 200-T User manual

Viessmann

Viessmann Vitosol 200-T User manual

Viessmann VITOSOL 200-F User manual

Viessmann

Viessmann VITOSOL 200-F User manual

Viessmann Vitosol 300-T User manual

Viessmann

Viessmann Vitosol 300-T User manual

Popular Solar Panel manuals by other brands

Phoenix Solar TectoFlat Installation instructions and use

Phoenix Solar

Phoenix Solar TectoFlat Installation instructions and use

Projoy Electric PEFS-PL80S-11 installation guide

Projoy Electric

Projoy Electric PEFS-PL80S-11 installation guide

Redland ST4 installation instructions

Redland

Redland ST4 installation instructions

Xantrex SOLAR Max Flex 784-0140-01 installation guide

Xantrex

Xantrex SOLAR Max Flex 784-0140-01 installation guide

Grape Solar CS-S-175-DJ Installation & user manual

Grape Solar

Grape Solar CS-S-175-DJ Installation & user manual

PATONA Crystal Panel 100 manual

PATONA

PATONA Crystal Panel 100 manual

Taurus PFL-0335-TG Original instructions

Taurus

Taurus PFL-0335-TG Original instructions

baxiroca Sol Series Installation

baxiroca

baxiroca Sol Series Installation

Conrad TPS-103 2W/6V operating instructions

Conrad

Conrad TPS-103 2W/6V operating instructions

AgfaPhoto SP60 user manual

AgfaPhoto

AgfaPhoto SP60 user manual

HelioSphera HS Series Safety and installation instructions

HelioSphera

HelioSphera HS Series Safety and installation instructions

Index SC-GSC instructions

Index

Index SC-GSC instructions

AKO-Agrartechnik BA-1161 instruction manual

AKO-Agrartechnik

AKO-Agrartechnik BA-1161 instruction manual

ATEMPOWER AP300MS-B user manual

ATEMPOWER

ATEMPOWER AP300MS-B user manual

Solar Fabrik M Series Mounting instructions

Solar Fabrik

Solar Fabrik M Series Mounting instructions

Unique UGP-120WSPB owner's manual

Unique

Unique UGP-120WSPB owner's manual

Chicago Electric 90599 and Installation and service instructions

Chicago Electric

Chicago Electric 90599 and Installation and service instructions

Hyundai HiE-S415DG(FB) installation manual

Hyundai

Hyundai HiE-S415DG(FB) installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.