02973 - Connected dial thermostat
SMART HOME VIEW WIRELESS
Download the View Wireless App from the stores onto the tablet/smartphone
you will be using for configuration.
You will need:
Gateway art. 20597-19597-16497-14597
View App for management via smartphone/tablet
Alexa, Google Assistant, Siri and Homekit voice assistants for possible voice operation
CONFIGURATION IN
1. Create your Installer account on MyVimar (on-line).
2. Wire all the devices in the system (2-way switches, relays, thermostats, gateway, etc.).
3. Start the View Wireless App and log in with the credentials you just created.
4. Create the system and the environments.
5. Associate all the devices with the environments, except for the gateway (which should be
associated last).
To associate the thermostat:
• Select “Add” ( ), choose the environment to place it and give it a name
• Select ; activate the Bluetooth connection on your tablet/smartphone and approach
the thermostat
• Press for 5 s; the ring flashes blue and association is complete.
6. For every device, set the function, the parameters and any accessory devices (wired or radio
control and related function).
7. Transfer the configuration of the devices to the gateway and connect it to the Wi-Fi network.
8. Transfer the system to the Administrator user (who must have created his/her profile on
MyVimar).
For full details, see the View Wireless App manual that can be downloaded from the www.
vimar.com website.
RESETTING THE THERMOSTAT
The reset restores the factory settings. Within the first 5 minutes of powering, press for 30
s; during these 30 s the ring flashes blue and then emits 2 white flashes to confirm the operation.
INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with the
current regulations regarding the installation of electrical equipment in the country where the
products are installed.
• The C-NO contact of the relay must be protected against overloads by installing a device, fuse
or automatic 1-way switch, with a rated current not exceeding 10 A.
• Do not connect a SELV circuit to the C-NO terminals as there is no double insulation on the
L-N terminals
• The device must be installed in a flush mounting box or surface mounting box with the related
mounting frames and cover plates, at a height of 1.5 m above floor level, in a suitable position
for the correct detection of the room temperature, avoiding installation in recesses, behind
doors and curtains, areas affected by heat sources or subject to the flow of forced heating/
cooling ventilation sources or affected by atmospheric factors. Avoid in particular installation
on perimeter walls or in association with devices which generate heat (e.g. dimmers or lamps).
CHARACTERISTICS.
• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Dissipated power: 0.55 W.
• RF transmission power: < 100mW (20dBm).
• Frequency range: 2400-2483.5 MHz.
•Terminals:
- 2 terminals (L and N) for line and neutral
- 2 terminals for external temperature probe (art. 02965.1 and 20432-19432-14432)
Maximum length of the external sensor connection cable: 10 m.
Use a twisted cable with a minimum cross-section of 0.5 mm2(art. 01840).
- 2 C-NO relay terminals.
• Relay output with voltage-free contact: 5(2) A 240 V~
• Current settable setpoint: 4°C - 40°C.
• Temp. measurement precision (integrated probe): 0.5°C between +15°C and 30°C, 0.8°C at
the extremes
• For use for Heating/Air Conditioning (winter/summer).
• Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual
• Temperature control algorithms: ON/OFF or configurable PID
• 4 front buttons for control and configuration/reset
• RGB LED for configuration status (flashing blue) and output status (configurable colour) signalling
• Operating temperature: T40 (0 °C +40 °C) (indoor use)
• Protection degree: IP30
• ErP classification (EU Reg. 811/2013): - ON/OFF: class I, contribution 1%. - PID: class IV,
contribution 2%.
1
• Short press = degrees Celsius/Fahrenheit selection
• Long press (5 s) = the thermostat enters the configuration phase (bt)
• Prolonged press (30 s) within the first 5 min of powering = device reset (rst)
Display brightness and RGB LED in standby setting
• 1st press = current brightness display
• Subsequent presses = cyclic display of available brightness values L-3 (high), L-2
(medium), L-1 (low) and L-0 (off).
A
Display
• bt = devices in Bluetooth configuration
• off = thermostat off; on = thermostat on
• °C = degrees Celsius; °F = degrees Fahrenheit
• L-0, L-1, L-2, L-3 = brightness in standby (from the lowest to the highest)
• H = heating; C = air conditioning
• opn = open window (associated with the thermostat via magnetic contact art.
03980)
BDial
CLightable ring
• Power on and off.
Upon power on or off, the thermostat starts in the last operating mode associated
with it set via the View App.
• Heating or air conditioning mode selection.
Ring signalling
All flashing blue = thermostat in configuration mode
All lit amber* = thermostat in heating mode and relay active
All lit blue** = thermostat in air conditioning mode and relay active
1
• Lit amber * = thermostat in heating mode and relay not active
• Lit blue ** = thermostat air conditioning mode and relay not active
In standby, the brightness is set during configuration; otherwise, the value is the
maximum one.
2
• Flashing red = the thermostat, in automatic mode, has lost the hourly value and
has therefore switched to manual mode.
When it receives the hourly value from the gateway again, the thermostat returns
to automatic mode and the flashing ends.
* Amber with automatic colour or of the selected colour.
** Blue with automatic colour or of the selected colour.
A
BC
2
• Device in class II
• Number of manual cycles: 3,000
• Number of automatic cycles: 100,000
• Type of contact opening: micro-disconnection
• Type of action: 1BU
• Tracking index: PTI175
• State of pollution: 2
• Rated pulse voltage: 4000 V
• Software class: A
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02973 01 2106
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately
from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the
differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment
you want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver
electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a
sales area of at least 400 m2. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal
of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice
of reusing and/or recycling materials used in manufacture.
• Reading resolution: 0.1 °C
• Settings resolution: 0.1 °C
• Update of temperature displayed: every 10 s
• Room temperature display: 0 °C +40 °C
• Hysteresis adjustable via App: from 0.1 °C to 1 °C
• Hourly temperature setting (via App)
• Room temperature during transportation: -25 °C +60 °
• Clock error: ≤ 1 s per day
• With the View Wireless App, the Installer configures the thermostat and creates climate
control programmes.
• With the View Wireless App and the View App, the Administrator creates or modifies climate
control programmes.
• Controllable via View App, Alexa, Google, Siri and Homekit voice assistantfor
OPERATION.
In Bluetooth technology mode, the device should configured using the View Wireless App.
The App can be used to set the following parameters:
•Lighting in standby: high, medium, low, off; default = medium
• Circular ring indication selection: automatic or monochrome; default = automatic
• RGB colour selection: in the event of monochrome, possibility of setting the colour
•Temperature calibration for heating: between -5°C and +5°C with default = 0°C
•Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
•External probe use: deactivated, average with the internal one, replacing the internal one;
default = deactivated
•Relay output status: normally open, normally closed; default = normally open
•Control type: On/Off, PID; default = On/Off
•Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
•Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
•Integrative time for PID control: between 5 min and 120 min; default = 20 min
•Derivative time for PID control: between 0 and 255 s, disabled; default = 0
•Cycle time for PID control: between 10 min and 30 min; default = 10 min
The View Wireless App can also be used to associate a magnetic or wired contact of art.
03980 to turn off the temperature control system in the event of an open window; in this case,
the time for reaction and reactivation of contact opening and closing can be set:
•Reaction time: between 0 minutes (instantaneous) and 30 minutes; default = 0 minutes
• Reactivation time (time after which the thermostat is reactivated even without closing the
window): between 0 (disabled) and 12 hours; default = 1 hour.
The View App can be used to set:
• Time schedules (times and temperature levels T1, T2 and T3)
• Setpoint for all operating modes (Manual, Reduction, Absence, Protection)
• Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min
USE.
The front buttons, the display, the dial and the lighting of the circular ring around the display
can be used to set and display all the operating modes of the thermostat.
Use the dial to set a new setpoint. In particular, for operation in Bluetooth technology:
- in automatic operating mode, turn the dial for the thermostat to switch to manual operation
for a period of time which can be set on the View App;
- in manual operation or reduction mode, the thermostat remains in this mode and the setpoint
is that set on the dial.
REGULATORY COMPLIANCE.
RED Directive. RoHS directive. ErP directive.
EN 60730-2-7, EN 60730-2-9, EN 301 489-17, EN 300 328, EN 62479, EN 63000 standards.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
www.vimar.com
Temperature control device regulation (EU) no. 811/2013.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
CONNECTIONS: Circulation pumps, burners, solenoid valves and temperature probe
6 mm
100-240V~
50/60Hz
5(2)A
1.B.U
-T40
CNONL
20432-19432-14432
02965.1 02973
03980
6 mm
100-240
50/60Hz
-T40
CNONL
The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries
and Regions. App Store is a service trademark of Apple Inc. Google is a trademark of Google LLC. Amazon, Alexa and
all related logos are trademarks of Amazon.com, Inc. or its affiliates.

Other Vimar Thermostat manuals

Vimar 30810 Series User manual

Vimar

Vimar 30810 Series User manual

Vimar 02900.1 User manual

Vimar

Vimar 02900.1 User manual

Vimar BY-ME PLUS User manual

Vimar

Vimar BY-ME PLUS User manual

Vimar 02952 User guide

Vimar

Vimar 02952 User guide

Vimar 02905 User manual

Vimar

Vimar 02905 User manual

Vimar 01911 manual&nbsp;

Vimar

Vimar 01911 manual&nbsp;

Vimar radioclima User manual

Vimar

Vimar radioclima User manual

Vimar CLIMARADIO manual&nbsp;

Vimar

Vimar CLIMARADIO manual&nbsp;

Vimar RADIOCLIMA 01910 User guide

Vimar

Vimar RADIOCLIMA 01910 User guide

Vimar 02910 User manual

Vimar

Vimar 02910 User manual

Vimar 02907 User manual

Vimar

Vimar 02907 User manual

Vimar 2911 User manual

Vimar

Vimar 2911 User manual

Vimar 02973 User manual

Vimar

Vimar 02973 User manual

Vimar 2906 User manual

Vimar

Vimar 2906 User manual

Vimar By-me Eikon 20513 User manual

Vimar

Vimar By-me Eikon 20513 User manual

Vimar 2905 User guide

Vimar

Vimar 2905 User guide

Vimar 02907 User guide

Vimar

Vimar 02907 User guide

Vimar 01913 User manual

Vimar

Vimar 01913 User manual

Vimar 2911 User manual

Vimar

Vimar 2911 User manual

Vimar 02907 User manual

Vimar

Vimar 02907 User manual

Vimar 2950 User manual

Vimar

Vimar 2950 User manual

Vimar RADIOCLIMA 01910 manual&nbsp;

Vimar

Vimar RADIOCLIMA 01910 manual&nbsp;

Vimar SMART CLIMA 02912 User manual

Vimar

Vimar SMART CLIMA 02912 User manual

Vimar CLIMAPHONE User manual

Vimar

Vimar CLIMAPHONE User manual

Popular Thermostat manuals by other brands

Sonder Siesta-TA ECO RF manual

Sonder

Sonder Siesta-TA ECO RF manual

Honeywell Home RLV3150 user guide

Honeywell Home

Honeywell Home RLV3150 user guide

Radiant TS8100-DUAL-V instructions

Radiant

Radiant TS8100-DUAL-V instructions

Honeywell ST9400C user guide

Honeywell

Honeywell ST9400C user guide

Honeywell Y87RF manual

Honeywell

Honeywell Y87RF manual

Seitron TAG02M manual

Seitron

Seitron TAG02M manual

White Rodgers 1F86-0471 Installation and operating instructions

White Rodgers

White Rodgers 1F86-0471 Installation and operating instructions

Robertshaw RS7210 Installation & user manual

Robertshaw

Robertshaw RS7210 Installation & user manual

Conrad Electronic 61 05 78 operating instructions

Conrad Electronic

Conrad Electronic 61 05 78 operating instructions

Honeywell Super Tradeline T874G installation instructions

Honeywell

Honeywell Super Tradeline T874G installation instructions

Emerson White-Rodgers 1D56-310 installation instructions

Emerson

Emerson White-Rodgers 1D56-310 installation instructions

Neotherm Futura Z Pro manual

Neotherm

Neotherm Futura Z Pro manual

Flomasta 4718G Guide

Flomasta

Flomasta 4718G Guide

SKS Simka Smart1.0Pro Operation instructions

SKS Simka

SKS Simka Smart1.0Pro Operation instructions

Lux Products LUXPRO PSD022B Installation and operating instructions

Lux Products

Lux Products LUXPRO PSD022B Installation and operating instructions

Orbis NEXU user manual

Orbis

Orbis NEXU user manual

LK Armatur SmartComfort RTW instruction manual

LK Armatur

LK Armatur SmartComfort RTW instruction manual

EWC Controls EWT-601-2 installation manual

EWC Controls

EWC Controls EWT-601-2 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.