1. Power-on Mode: 1) Install the battery into the module 2) The detector will emit a
beep in 0.5 second and the three LEDs will flash once quickly. 3) Close the bracket.
The CO detector will alarm once remove the bracket.
2. Stand-by Mode: The Green LED flashes once every 60 seconds.
3. Alarm Mode (In the status when the sensor is triggered.): If a certain density of
CO is detected, an audible alarm with 4 beeps, pause 5 seconds and 4 beeps will
occure. The red LED will flash continuously and rapidly.
4. Trigger Alarm Report:
* While certain desity CO is detected-
Sending Basic Set On and Alarm Report (Type: 0x02,Level:0xFF,Event=0x02)
* While certain density CO isn’t detected-
Sending Basic Set Off andAlarm Report (Type: 0x02,Level:0x00,Event=0x00)
* Long pressing test switch for 3 seconds-
Sending Basic Set On and Alarm Report (Type: 0x02,Level:0xFF,Event=0x02)
* After release test switch for 2 seconds-
Sending Basic Set Off andAlarm Report (Type: 0x02,Level:0x00,Event=0x00)
* Remove the detector from the bracket-
Sending Alarm Report (Type: 0x07,Level:0xFF,Event=0x03)
* Fix the detector back to the bracket-
Sending Alarm Report (Type: 0x07,Level:0x00,Event=0x00)
5. Error Mode: If the CO detector beep once and yellow LED flash three times per
minute, it indicates the CO detector is not working properly. Please require to repaire
or service.
6. Low battery warning Mode: The yellow LED will flash once per minute with a
“beep”sound.
7. Low sensitivity Mode: The yellow LED will flash twice per minute with a “beep”
sound. It indicates the CO detector has internal problem, please replace the unit.
8. Tamper Mode: The yellow LED will go solid and the detector will emit a short beep
per minute untill the CO detector is mounted back to the bracket properly.
9. End of life signal Mode: The yellow LED will flash four times every minute with a
short “beep”sound. It indicates the CO detector is reaching to the end of useful life,
please replace with a new unit.
10. Testing Mode: Test the alarm by pushing test switch until the user hear 4 short
beeps and three LEDs flash synchronously in five senconds. Then, the CO detector
will send an alarm report (Alarm type: 0x02, Level: 0xFF) to the user’s controller and
also the CO dectecor will send an alarm report (Alarm type: 0x02, Level:0x00) while
the alarm off. Please note if the CO detector only beep once and yellow LED falsh
three times every minute, it indicates the CO detector is not working properly.
Please require to repair or service.
11. Battery Power indicator: The detector will send Battery low signal if under 3.6±
0.1V automatically. Could using “Battery Get”command to have the battery capacity
in percentage.
12. Silence Mode: The user could press the test switch to get into silence mode to turn
off the alarm temporarily when the CO detector alarm. Meanwhile, the red LED will
flash continually. The silence function will automatically turn into normal operation if
the CO concentration around the CO detector isstill at alarming level after 4 minutes
of silence mode.
13. OTA Function: The detector support OTA function, please use
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 command to update the
firmware.
14. Security enabled_Z-Wave controller must be used to fully utilize the product.