Vivreau V3-203 User manual

Owner’s Manual
MODEL
V3-203
Freshly-drawn Traditionally Served Environmentally Friendly Specially Branded
170207
V3 Dispensing System

2V3-203 Dispensing System Owner’s Manual
© 2017 Vivreau USA
All rights reserved.
Any and all information contained within this document is
subject to change without prior notice.
IMPORTANT ______________
The information contained in this manual is specific to
your system. It is IMPORTANT you READ, FOLLOW and
UNDERSTAND the instructions given.
This manual and all material provided with your system
should be retained in a convenient location for future
reference.
Contact Vivreau if you have any questions regarding
the information contained in this manual.

V3-203 Dispensing System Owner’s Manual 3
TABLE OF CONTENTS
SAFETY PRECAUTIONS ...........................................................5
GENERAL INFORMATION .........................................................7
TECHNICAL SPECIFICATIONS ..................................................9
PRE-INSTALLATION REQUIREMENTS ................................... 11
OPERATING INSTRUCTIONS..................................................13
MAINTENANCE........................................................................17
TROUBLESHOOTING...............................................................23

4V3-203 Dispensing System Owner’s Manual

V3-203 Dispensing System Owner’s Manual 5
Section 1
Safety Precautions
SAFETY PRECAUTIONS
IMPORTANT _________________________
This manual is intended for use only by
personnel trained in the operation of the
Vivreau V3-203 Dispensing System.
WARNING
Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury, or death. Read the
installation, operating, and maintenance
instructions thoroughly before installing or
servicing this equipment.
WARNING
Keep the area around the unit
clear of any combustible materials.
WARNING
Do not store or use gasoline
or other flammable vapors or liquids in the
vicinity of this or any other unit.
IMPORTANT _________________________
Carefully read, understand and follow all
safety instructions in this manual and safety
labels on the unit.
• Keep safety labels in good condition and
replace missing or damaged items.
• Learn how to operate the unit and how to use
the controls properly.
• Do not let anyone operate the unit without
proper training. This unit is intended for use
by authorized personnel only.
• In the event of a power failure, do not
attempt to operate this unit.
• Keep unit in proper working condition and
do not allow unauthorized modifications to
the unit.
WARNING
Only trained and certified electrical,
plumbing and refrigeration technicians should
service this unit.
WARNING
ALL WIRING AND PLUMBING
MUST CONFORM TO NATIONAL AND LOCAL
CODES. FAILURE TO COMPLY COULD RESULT
IN SERIOUS INJURY, DEATH OR EQUIPMENT
DAMAGE.
SAFETY PRECAUTIONS ________________
This unit has been specifically designed to
provide protection against personal injury.
To ensure continued protection, observe
the following:
WARNING
Disconnect power to the unit
before servicing. Follow all LOCKOUT/TAGOUT
procedures. Verify power to the unit is OFF and
disconnected before any work is performed. Failure
to do so could result in serious injury, death or
equipment damage.
• To protect against electric shock, do not
immerse power cord in water or other
liquid.
• To prevent damage to the power cord, do
not allow cord to hang over the edge of a
table or counter, or come in contact with
hot surfaces.
• Isolate unit from power supply (unplug or
turn OFF breaker) and turn OFF the water
supply when not in use and before cleaning.
• Allow Boiler (if supplied) to cool before
removing any components.
• The use of spare parts and accessories
not recommended by Vivreau may cause
damage and/or injuries.
• Do not operate any unit with damaged
cords, plugs, or after the unit malfunctions
or has been damaged in any manner.
• Do not use outdoors.
• Do not place on or near a hot gas or electric
burner.
• Do not use the unit for anything other than
its intended use.
• Save these instructions.

6V3-203 Dispensing System Owner’s Manual
Section 1
Safety Precautions

V3-203 Dispensing System Owner’s Manual 7
Section 2
General Information
GENERAL INFORMATION
INFORMATION FOR THE READER
To find specific topics of interest quickly, refer
to the Table of Contents at the beginning of this
manual.
This manual is solely for the use of personnel
trained in the operation of the Vivreau V3-203
Dispensing System only.
PURPOSE OF THE MANUAL
• Vivreau has produced this manual to provide
necessary information to qualified and
authorized personnel for the safe and proper
installation, operation, and maintenance of
the Vivreau V3-203 Dispensing System.
• Information contained in this manual will
help prevent risks to health and safety, and
the risk of economic losses.
• Keep this manual in a clearly identified and
safe place throughout the working life of the
unit, so that it will always be available as
needed.
• The manufacturer reserves the right to
make modifications to the unit without any
obligation to provide prior notice.
• A number of symbols have been used to
highlight particularly important parts of
the text or important specifications. Their
meaning is as defined below.
DANGER
INDICATES AN IMMINENTLY HAZARDOUS
SITUATION WHICH, IF NOT AVOIDED, WILL
RESULT IN DEATH OR SERIOUS INJURY.
WARNING
Indicates that suitable procedures must be
adopted to avoid putting people’s health and
safety at risk or causing economic losses.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, may result in property
damage, minor or moderate injury.
IMPORTANT _________________________
Indicates important technical information
which
must not
be overlooked.

8V3-203 Dispensing System Owner’s Manual
Section 2
General Information

V3-203 Dispensing System Owner’s Manual 9
Section 3
Technical Specifications
TECHNICAL SPECIFICATIONS
GENERAL DESCRIPTION
TheVivreauV3-203 Dispensing System is designed
to provide Chilled Water on demand.
There are two (2) orientations of the Vivreau V3-203
Dispensing System; Model V3-203A incorporates a
horizontal Chiller and Model V3-203B incorporates
a vertical Chiller.
Performance is the same for both models
and selection is based on space available for
installation.
The system has been designed for operation at
ambient temperatures up to 90ºF.
Dispensing Specifications
Description Specification V3-203A V3-203B
Chilled still water ΔT=18 °F @ 15.8 gal/h ü ü
Water Pressure at Dispensing Head 5 PSI ü ü
Operating Conditions
Description Specification V3-203A V3-203B
Temperature 60 – 90°F ü ü
Relative Humidity 60% (max.) ü ü
Water Supply Requirements
Description Requirements V3-203A V3-203B
1/2” FNPT connection with Ball Valve 1/2” ü ü
PSI (min.) 50 ü ü
GPH (min.) 80 ü ü
Temperature (max.) 60°F ü ü
Drain Vented Stand-Pipe ü ü
Cooler Specifications
Description V3-203A V3-203B
Width 25.4” 14.0”
Height 10.0” 27.0”
Depth 15.3” 14.0”
Shipping Weight 76 lbs. 80 lbs.
Voltage 110/120 VAC / 60 Hz 110/120 VAC / 60 Hz
Amperage 11 A 11 A

10 V3-203 Dispensing System Owner’s Manual
Section 3
Technical Specifications

V3-203 Dispensing System Owner’s Manual 11
Section 4
Pre-Installation Requirements
PRE-INSTALLATION REQUIREMENTS
INTRODUCTION
The Vivreau V3-203 Dispensing System is an
under-counter Water Dispensing System.
Vivreau V3-203 Dispensing System
PRE-INSTALLATION
Below are the services required to be in place
prior to the installation of the Vivreau V3-203
Dispensing System. If you have any questions
regarding these or other services, please contact
Vivreau Service Toll-Free at 877-999-1044.
WATER SUPPLY
One (1) potable 1/2” cold water supply terminating
in a 1/2” NPT Ball Valve, 1/2” female pipe thread.
IMPORTANT _________________________
Ball Valve must be accessible for service and
installation.
Minimum Water Pressure: 50 PSI
Minimum Water Flow: 80 gallons per hour
IMPORTANT _________________________
The Vivreau V3-203 Dispensing System
incorporates back-flow prevention. Any
additional back-flow devices required by Federal,
State or Local Code must also be supplied by the
customer prior to installation. There must not be
any other Filters/Pre-Filters inline before the unit.
ELECTRICAL OUTLET
Model V3-203
(1) 15 Amp Electrical Receptacle (NEMA 5-15R)
120V, 60 Hz (11 Amps)
DRIP TRAY AND DISPENSING HEAD
CUTOUTS
Cut out the holes for the DripTray and Dispensing
Head per the supplied template.
NOTE: The Dispensing Head must be mounted
on the work surface directly above the Chiller.
15/8"
27/8"
37/8"51/8"
121/8"
Drip Tray and Dispensing Head Cutout Dimensions

12 V3-203 Dispensing System Owner’s Manual
Section 4
Pre-Installation Requirements
VENTILATION
If the system is to be installed in an enclosed
space or in a cabinet, adequate ventilation must
be provided.
CAUTION
Failure to provide adequate
ventilation will cause system failure.
This unit is to be installed indoors only.
41/2"
51/8"
Available VIVREAU Grille
11 3/4"
11 "
3/8"
45/8"
2"
45/8"
2"
PLEASE NOTE
All vents must open to fresh air
in a free and unobstructed area.
Front Ventilation
Showing ventilation
grilles
cut in a standard
door panel
Cut-out detail for the
VIVREAU grille, shown in
a 23.5"
(24") wide door
Side Ventilation
Ventilation grilles cut in the side
of a
standard 24" cabinet. The grilles
may
be fitted on either side, provided they
ventilate into a free, unobstructed area.
Base Ventilation
Ventilation grilles cut in the cabinet's
base
panel and base plinth. Top ventilation
will also
be required in either the side panels
or a
cut-out in the top of the door.
Base Cutout
Ventilation can be made through the base of the cabinet, with the removal
of a narrow section
of floor immediately behind the door. Trim
with roll
edging strip. Cut-out size must not be less than 11.0" wide x 1.5" deep.
Ventilation Options

V3-203 Dispensing System Owner’s Manual 13
Section 4
Pre-Installation Requirements
INSTALLATION
IMPORTANT _________________________
Installation must be performed by properly
trained and qualified persons and comply with
Federal, State and Local Codes for connection
to electrical supplies, water supplies and
pressurized gas systems.
Note: Vivreau cannot be held responsible for
any damage caused by improper installation.
LOCATION
A completed Pre-installation Checklist must
be available prior to installation. The Vivreau
Dispensing System must be installed indoors
where the ambient air temperature will not
exceed 90°F.
The Vivreau V3-203 Dispensing System should not
be exposed to spills, spray, steam or high humidity.
A suitable location should be chosen within 40”
of the electrical and water supply connections.
TheVivreauV3-203 Dispensing System is designed
to be installed in an under-counter cabinet with
adequate ventilation for component cooling.
Cabinet opening required by model:
Model V3-203A: 30” or greater
Model V3-203B: 24” or greater
Do not obstruct air vents.
Install the system on a firm, level floor or base.
35
3
8
"
12
7
8
"
30"
Min. Cabinet Width
Min. Cabinet Width
24"
35
3
8
"
12
7
8
"
V3-203A-1
NEMA 5-15 Double Socket
V3-203B-1
Filter
Stand-Pipe
Terminate 24" above the floor
Main Water Inlet
Terminate 24" above the floor
Chiller
NEMA 5-15 Double Socket
Filter
Stand-Pipe
Terminate 24" above the floor
Main Water Inlet
Terminate 24" above the floor
Chiller
Vivreau V3-203A and V3-203B Under-counter Installation Setup

14 V3-203 Dispensing System Owner’s Manual
Section 4
Pre-Installation Requirements

V3-203 Dispensing System Owner’s Manual 15
Section 5
Operation
OPERATING INSTRUCTIONS
DISPENSING
Before operating the Vivreau V3-203 Dispensing
System, make sure the Water Supply Valve is
open and the unit is plugged in.
Place appropriate container on DripTray beneath
Dispensing Head.
Chilled Still Water
Pull DOWN on Blue Dispenser Handle. Push
Dispenser Handle UP when full.
Dispensing Chilled Still Water
The Dispenser Handle should be fully opened
when filling and fully closed when filling is
complete.
IMPORTANT _________________________
Do not allow the Dispenser Handle to slam shut.
The Vivreau V3-203 Dispensing System is
designed to fill Bottles of up to one (1) liter, one
Bottle at a time.
The Dispenser Handle must be closed after each
Bottle is filled.
Vivreau Bottles should be filled to the line in the
neck just below the Cap.
At the end of service, remove the Black Dispenser
Nozzle and soak in Sanitizing Solution.
The Dispenser and Unit should be wiped down
with Sanitizing Solution to keep the Dispensing
System clean and in hygienic condition.
Once the Unit is wiped down and Nozzle
removed, the Dispenser must be wrapped in
plastic wrap to prevent contamination and
misuse while not in service.
To return the Vivreau V3-203 Dispensing
System to service remove all plastic wrap and
rinse Dispenser Nozzle.
Reinstall the Nozzle into the Dispenser Head.
The Vivreau V3-203 Dispensing System is
designed for ease of use.
IMPORTANT _________________________
Before operating theVivreauV3-203 Dispensing
System, make sure the water supply is turned
ON and the unit is plugged in.
BEFORE USE
A LWAYS sanitize your hands.
A LWAYS wear hygienic gloves.
A LWAYS remove anti-bacterial cling film from
the Dispensing Head.
A LWAYS wipe Dispensing Head, Nozzle, Drip
Tray and cabinet work-surface with anti-bacterial
wipes.

16 V3-203 Dispensing System Owner’s Manual
Section 5
Operation
AFTER DAILY USE
At the end of service, remove the Black Dispenser
Nozzle and soak in Sanitizing Solution for a
minimum of four (4) hours.
Remove Dispenser Nozzles
Always wear protective gloves when in contact
with Sanitizing Solution.
The Dispenser and unit should be wiped down
with Sanitizing Solution to keep the Dispensing
System clean and in hygienic condition.
Clean Drip Tray
Once the unit is wiped down and Nozzle
removed, the Dispenser must be wrapped in
plastic wrap to prevent contamination and
misuse while not in service.
To return the Vivreau V3-203 Dispensing
System to service remove all plastic wrap and
rinse Dispenser Nozzle.
Reinstall the Nozzle into the Dispenser Head.
BOTTLE CLEANING INSTRUCTIONS
IMPORTANT _________________________
Use ONLY Vivreau Dishwasher and Storage
Racks.
Make sure the Bottling System and surrounding
areas are kept clean and sanitary.
After Bottles have been used, empty remaining
contents and place Bottles in Red Storage Racks.
CLEAN USED
Bottle Storage
Bottles MUST be handled with care and should
not be allowed to rub and bang together. This
could cause weakness in the glass, which may
not be visible.
A LWAYS use Vivreau Storage and Dishwasher
Racks.
DO NOT empty into Vivreau V3-203 Dispensing
System DripTray.
New Bottles MUST be sanitized before first use.
A LWAYS inspect Bottles for damage. Any Bottles
showing signs of damage or cracks should be
discarded and recycled appropriately.
A LWAYS visually check Bottles for food particles
or any other solids.
A LWAYS wash Bottles in a three compartment
sink (wash water, rinse water and sanitizer) in
accordance with Local Health Codes.
A LWAYS sanitize Bottles in dishwasher.

V3-203 Dispensing System Owner’s Manual 17
Section 5
Operation
A LWAYS place Bottles upside down in Bottle
Washing Rack.
Bottle Storage
A LWAYS leave Caps attached to Bottle during
sanitization. DO NOT close Cap.
A LWAYS keep Bottles in tray and remove from
washer after Sanitization Process.
A LWAYS leave Bottles in tray until cool and dry.
DO NOT close Cap.
A LWAYS secure Cap after Bottles have cooled.
A LWAYS visually inspect Bottles for damage
before storing.
A LWAYS place Bottles upright in Blue Storage
Racks.
Storage Racks can be stacked.
A LWAYS place plastic film over the top crate to
ensure exterior of Bottles are kept clean.
THE VIVREAU WATER BOTTLING SYSTEM
Eliminates the need for plastic-bottled mineral
water.
Helps reduce the unnecessary disposal of tens
of billions of plastic bottles.
Reduces Carbon Footprint by eliminating the
unnecessary daily transportation (ships, trains
and trucks) of bottled water.
Water is filtered on demand using advanced
micro-filtration eliminating 99.99% of bacteria,
contaminants, additives, such as chlorine, odors
and other impurities while allowing the natural
minerals to remain for a clean, clear taste.

18 V3-203 Dispensing System Owner’s Manual
Section 5
Operation

V3-203 Dispensing System Owner’s Manual 19
Section 6
Maintenance
MAINTENANCE
MAINTENANCE RECOMMENDATIONS
Keep the unit at peak efficiency by performing
all scheduled maintenance procedures that are
recommended by the manufacturer. Proper
maintenance will allow the best performance
and a longer working life.
WARNING
Before performing any service
procedure, perform all safety procedures. In
particular, turn OFF the water supply, disable
the electricity at the main circuit breaker
and prevent access to all devices that might
cause unexpected health and safety hazards
if turned ON.
WARNING
Before performing any service
that involves electrical connection or
disconnection and/or exposure to electrical
components, ALWAYS follow the Electrical
LOCKOUT/TAGOUT Procedure. Disconnect all
circuits. Failure to comply can cause property
damage, injury or death.
At the end of each day or whenever necessary, be
sure to clean:
• Dispensing Head/Nozzle
• DripTray
• The surrounding work area
Every year, have skilled, authorized personnel
perform the following operations:
• General check of the unit
• Identify and replace worn parts
IMPORTANT _________________________
Record all yearly inspections.
IMPORTANT _________________________
Contact the factory, the factory representative
or an authorized service agent to perform
maintenance and repairs.
ELECTRICAL LOCKOUT/TAGOUT
PROCEDURE
WARNING
Before performing any service
that involves electrical connection or
disconnection and/or exposure to electrical
components, ALWAYS follow the Electrical
LOCKOUT/TAGOUT Procedure. Disconnect all
circuits. Failure to comply can cause property
damage, injury or death.
The Electrical LOCKOUT/TAGOUT Procedure is
used to protect personnel working on an electrical
unit. Before performing any maintenance or
service that requires exposure to electrical
components, follow these steps:
In Electrical Box, place unit Circuit Breaker into
OFF position.
Place a lock or other device on the Electrical Box
Cover to prevent someone from placing Circuit
Breaker in the ON position.
Place a tag on Electrical Box Cover to indicate
that unit has been disconnected for service
and power should not be restored until tag is
removed by maintenance personnel.
Disconnect the unit’s Power Cord from Electrical
Outlet.
Place a tag on the Power Cord to indicate that
the unit has been disconnected for service
and power should not be restored until tag is
removed by maintenance personnel.

20 V3-203 Dispensing System Owner’s Manual
Section 6
Maintenance
STAINLESS STEEL CARE
Cleaning
Stainless steel contains 70-80% iron, which will
rust if not properly maintained. It also contains
12-30% chromium, which forms an invisible
passive, protective film that shields against
corrosion. If the film remains intact, the stainless
steel will remain intact. However, if the film is
damaged, the stainless steel can break down and
rust.To prevent stainless steel breakdown, follow
these steps:
CAUTION
Never use any metal tools. Scrapers,
files, wire brushes or scouring pads (except for
stainless steel scouring pads) will mar the surface.
CAUTION
Never use steel wool, which will
leave behind particles that rust.
CAUTION
Never use acid-based or chloride-
containing cleaning solutions, which will break
down the protective film.
CAUTION
Never rub in a circular motion.
CAUTION
Never leave any food products
or salt on the surface. Many foods are acidic.
Salt contains chloride.
For routine cleaning, use warm water, mild soap
or detergent and a sponge or soft cloth.
For heavy-duty cleaning, use warm water, a degreaser
and a plastic, stainless steel or Scotch-Brite pad.
Always rinse thoroughly.
Always rub gently in the direction of the steel
grain.
Preserving & Restoring
Special stainless steel polishing cleaners can
preserve and restore the protective film.
Preserve the life of stainless steel with a regular
application of a high quality stainless steel
polishing cleaner as a final step to daily cleaning.
If signs of breakdown appear, restore the
stainless steel surface. First, thoroughly clean,
rinse and dry the surface. Then, on a daily
basis, apply a high-quality stainless steel polish
according to manufacturer’s instructions.
Heat Tint
Darkened areas, called heat tint, may appear
on stainless steel exposed to excessive heat,
which causes the protective film to thicken. It is
unsightly but is not a sign of permanent damage.
To remove heat tint, follow the routine cleaning
procedure. Stubborn heat tint will require
heavy-duty cleaning.
To reduce heat tint, limit the exposure of
equipment to excessive heat.
DAILY CLEANING
The Vivreau V3-203 Dispensing System should
be cleaned once a day.
Vivreau recommends using disinfectant spray
or a sanitizing wipe for cleaning.
If the Dispensing Head becomes soiled with
coffee, tea, milk, etc., clean with hot soapy water
using a non-abrasive cloth.
Clean the DripTray Cover and inside the DripTray
using either disinfectant spray (non-chlorine) or
hot, soapy water and non-abrasive cloth.
Keep area around the unit clean and sanitized.
Vivreau V3-203 Dispensing System equipment
in the under-counter area should be kept free of
dust; the ventilation should not be obstructed
restricting free air flow around the equipment.
The Vivreau V3-203 Dispensing System Nozzle
should be removed daily and cleaned with hot
soapy water and a non-abrasive cloth.
After completing all cleaning tasks, dispense
water for at least 10 seconds to flush through
the Nozzle.
DO NOT use any abrasive material on your
Vivreau V3-203 Dispensing System.
This manual suits for next models
2
Table of contents
Other Vivreau Dispenser manuals