WAC TERMINATOR UV User manual

TERMINATOR UV
Installation Instructions
works with the
Google Assistant

Please read and save these
instructions before installation

For all questions about your ceiling fan please read all
included instructions, installation procedures, trouble-
shooting guidelines and warranty information before
starting installation.
For fast service have the following information below
when you call:
For missing parts or general inquiries
call our trained technical sta at:
• Model Name and Number
• Part Number and Part Description
• Date Of Purchase and Purchase Location
Email: [email protected]
Or live chat at www.waclighting.com
Email: fansupport@waclighting.com
1-800-526-2588 option 01-800-526-2588 option 3
MON-FRI 8AM-8PM EST MON-FRI 8AM-8PM EST
GENERAL INQUIRIES FAN SUPPORT
DO NOT RETURN TO STORE

SAFETY RULES
breaker before beginning. All wiring must be in accordance with the National Electrical
Code “ANSI/NFPA 70” and local electrical codes. Electrical installation should be performed
by a licensed electrician. The fan must be mounted with a minimum of 7 ft. (2.1m)
(0.5m) from the edge of the fan blades to the surrounding walls. Do not install this product
set forth in the user manual. Failure to use the product as instructed may cause serious
injury or damage. Never place objects in the path of the fan blades. To avoid personal
injury or damage to the fan and other items, please be cautious when working around or
water or chemicals when cleaning the fan or fan blades. A dry cloth or lightly dampened
cloth will be suitable for most cleaning. After making electrical connections, spliced
conductors should be turned upward and pushed carefully up into the outletbox. The
wires should be spread apart with the grounded conductor and the equipment-grounding
conductor on one side of the outletbox, and the ungrounded conductor on the other side
of the outletbox.
All set screws must be checked and re-tightened where necessary before installation.
WARNING: UV Radiation Hazard. The lamp in this unit produces UV-C radiation. Direct
exposure of skin and eyes to UV-C radiation may cause damage similar to sunburn reaction
UV-C lamp. Skin burns and eye injuries from UV-C exposure usually resolve within a week
with no known long-term damage. Since the penetration depth of UV-C radiation is very
low, the risk of skin cancer, cataracts or permanent vision loss is also thought to be very
low. The type of eye injury associated with exposure to UV-C causes severe pain and a
feeling of having sand in the eyes. Sometimes people are unable to use their eyes for one
to two days. It can occur after a very short exposure (seconds to minutes) to UV-C radiation.
This product, including the UV-C lamp and all of the products components, should be used
as instructed in the user manual, including complying with all adequate safety safeguards,
including but not limited to, those indicated in the mounting instruction and/or user
manual. This product must be mounted and installed as instructed to ensure that the
UV-C lamp can be operated in a safe way.
WARNING: Do not install or use your fan if any part(s) is/are damaged or missing. This
product is designed for use only with the supplied parts and/or accessories designated for
use with this product by WAC. Substitution of parts or accessories not designated for use
with this product by WAC could result in personal injury or property damage and will void
the warranty. Contact an authorized dealer or the manufacturer if any parts are damaged
or missing.
WARNING: To reduce the risk of electric shock, this fan must be installed and operated
with the supplied wall control, or controlled from the WAC app.
WARNING: Do not use power tools to assemble or install your fan. Using power tools can
result in improper assembly which can lead to noise or fan damage,personal injury or
property damage.
WARNING: To reduce the risk of personal injury, do not bend the
blade arms when installing the brackets, balancing the blades or cleaning the fan.
WARNING: Do not insert foreign objects between rotating fan blades.
WARNING: Do not operate fan unless fan blades are in place. Noise and fan damage can
occur
WARNING: This appliance is not intended for use by young children without supervision.
WARNING:
other items, the outletbox and support structure must be securely mounted and capable
of reliably supporting a minimum of 35 Ibs (15.9 kg). Use only UL/cUL listed outletboxes
marked “FOR FAN SUPPORT.” Use only the screws and washers provided with the outletbox.
CAUTION: Before assembling your fan, refer to the“Making the Electrical Connections“
section. If you feel you do not have enough wiring knowledge or experience, have your
fan installed by a licensed electrican.
NOTE
NOTE: Suitable for Damp location per UL safety requirment.
For operation, maintenance, and troubleshooting information, visit http://waclighting.com/fan-support/

02 SAFETY RULES
WARNING: This equipment is designed for use with germicidal UV radiation sources and
must be installed in compliance with technical directions to prevent risk of personal injury
from UV radiation.
WARNING: UV radiation can pose a risk of personal injuries. Direct exposure can result in
damage to eyes and skin. To reduce risk of exposure this equipment must be installed in
accordance with the manufacturer’s installation instructions.
WARNING:
be considered as part of site planning. For example, UV light may lead to a change in the
color of paint that has not been UV stabilized. Fading or discoloration of materials directly
exposed to UV radiation should be considered normal wear. Use normal paints for the
surface (e.g., the ceiling) above the fan as they substantially absorb UV light. Do not paint
WARNING: It is the responsibility of the installer to ensure that persons will not be directly
exposed to UV or optical radiation during equipment operation. This will require the
installer to conduct an assessment of irradiance or illuminance levels in the surrounding
occupied spaces prior to occupancy.
WARNING: Equipment must be mounted in locations and heights where it will not be
readily subjected to tampering by unauthorized personnel.
WARNING: The use of accessory equipment not recommended by the manufacturer may
cause an unsafe condition.
WARNING: Do not use this equipment for any purpose other than intended use.
WARNING:
WARNING: Maintenance and servicing of this UV product must be performed by
authorized personnel. Service personnel must wear appropriate Personal Protective
Equipment (PPE) if the equipment will be in operation during the maintenance or servicing
work. Contact the equipment manufacturer for PPE recommendations and guidance.
Do not install the fan where the top of the UV module can be visible, for
example, beneath a catwalk or breezeway that will permit direct exposure to UV radiation.
Disclaimer: While there may be information here or on our website relating to the
SARS-CoV-2 , WAC Lighting makes no claims that its products can cure, treat or
prevent any conditions, including COVID-19. Always consult your healthcare
provider with any health-related questions. Whole room pathogen concentrations
will vary between installation locations, and the number of TERMINATOR UV fans installed,
TERMINATOR UV fans installed, and it is not possible to predict the extent of
reductions that will be achieved by the TERMINATOR UV in whole room air
in any particular room or environment. The TERMINATOR UV is not a substitute for good
building air exchange practices or manual cleaning and disinfection practices.
UV Safety Rules
THIS PRODUCT EMITS ULTRAVIOLET (UV) RADIATION. EXPOSURE TO UV
RADIATION CAN CAUSE SERIOUS PERSONAL INJURIES, INCLUDING DAMAGE TO
EYES AND SKIN. AVOID DIRECT EXPOSURE TO THE UV LIGHT. FOR MORE SAFETY
INSTRUCTIONS, PLEASE REFER TO PAGE 5 OF THE INSTRUCTION MANUAL (“UV
SAFETY RULES”).
Disclaimer: Failure to use the product as instructed may also negatively impact the
product’s eectiveness. Manufacturer and its aliates do not promise or warrant that the
use of this product will protect or prevent any user from infection and/or contamination.
This product is not approved nor intended to be used to disinfect any device, including
medical devices. In addition to and without limitation of any exclusions or limitations of
liability of the manufacturer and its aliates as set forth in the user manual or any
agreement for sale, distribution or otherwise making available of this product, the
manufacturer and its aliates shall have no responsibility or liability whatsoever for any
claim or damage that may arise from or relate to any use of this product outside of its
intended use or contrary to the installation and operation instructions, as described in the
user manual and any other documentation provider to the user, including mounting
instruction.

This WAC Smart Fan is:
DC
MOTOR
The WAC app synchronizes seamlessly with smart home devices you already own
GET SMART
works with the
Google Assistant
APP DOWNLOAD
Available for purchase on
the Google Pay and App Store
Quiet, reliable, and up to 70%
Wi-Fi and Bluetooth enabled
for unlimited control
Damp location-listed to the strictest
UL/cUL safety regulations
Compatible with our WAC app
Coordinate with smart devices
for voice-activated control
REMOTE CONTROL
RCUV-WT
Included with
each fan
6 fan speeds
Dims light to 1%
ON/OFF

Package Contents
Mounting Options
Installing the Mounting Bracket
Attaching the Fan Blades
Hanging the Fan
Making the Electrical Connections
Finishing the Installation
Installing the Adapter Plate
Installing the Cover
Controlling the Fan
Reset
Application
Accessories
Troubleshooting
9.
10.
10.
11.
12.
14.
15.
16.
17.
19.
20.
21.
24.
25.
4
7
8
9
10
11
12
13
14
15
5
5
6
7
TABLE OF CONTENTS

F-069U
8
Electrical tape
Phillips screwdriver Step ladder Wire cutters
NOTE: Before discarding packaging materials, be certain all parts have been removed.
NOTE: Place the parts from the hardware bag into a small container to keep them from being lost.
Hanging Weight: 14.5 lbs
MAC ID
03 TOOLS & MATERIALS REQUIRED
IMPORTANT: Please make note of the MAC ID on the receiver and keep it in a safe place.

9F-069U
NOTE:
NOTE: UV module comes pre-assembled onto the motor housing
1
6
3
8
5
4
13
2
7
10 12
1, 2
1If you need a replacement UV module - please order part no. UVF7IN-120V-R1-MODT
2If you need replacement glass pieces - please order part no. RPL-F-UV7IN-GLASS
Canopy Ring
RPL-CAN-CYL-**
Adapter Plate
Coupling
Cover
Hardware Bag
RPL-F069-PARTS
Canopy
RPL-CAN-CYL-**
Motor Housing,
Glass Pieces 2/2,
and UV module
Fan Blade 3/3
RPL-F069-60-BD-**
Remote Control
RCUV-WT
PACKAGE CONTENTS 04
Downrod
Assembly
RPL-HGR-ASM-8-**
Mounting
Bracket
RPL-HGR-ASM-8-**
Cover
RPL-F069U-COVER-** Receiver
F-R3-069-060
14
A: Junction Box
#10x38mm Pan Head Phillip Screws (2)
Ø5*14*1mm Flat Washer (2)
3/16” Star Washer (2)
B: Blades
1/4” x16mm+S Phil/Slotted Screws (7)
1/4” Φ6.6x13x0.8mm Flat Washer (7)
C: Safety Cable
Φ6.5x19x2mm Flat Washer (1)
3/16”(Φ5.2x8.4x1.0mm)
Wood Screws (1)
D: Wire Connectors (8)
(Found with the receiver)
Spring Washer

F-069U
10
2
05 MOUNTING OPTIONS INSTALLING THE MOUNTING BRACKET
1. Remove 1 set screw from mounting bracket and set aside for
use in Finishing the Installation.
2. Pass supply wires through mounting bracket and secure to
your cUL/UL outlet box. Your outlet box should come with
pre-installed screws for the mounting bracket.
Caution: Remember to disconnect
the power at the circuit breaker.
CAUTION: To prevent electrical shock, ensure electricity has been
turned o at the circuit breaker before beginning.
Figures 1 and 2 are examples of dierent ways to mount the
outletbox.
Use Ahardware if needed to mount your outlet box.
1
Standard Ceiling Slope Ceiling
To Switch To Switch
(Hot) (Hot)/
Switch
(Ground) (Ground)
(No Neutral)
(Neutral) *Bare or
Green
*Bare or
Green
AA
B

11F-069U
31. Place blades on motor housing.
2. Secure blade with blade attachment screws and washers -
repeat for remaining blades. Use Bhardware.
ATTACHING THE FAN BLADES 06

F-069U
12
54
1. Remove screw from hanger ball. Remove hanger ball
and cross pin.
2. Loosen 2 screws, clevis pin and cotter pin.
1. Install coupling cover, canopy screw ring, canopy and
downrod assembly into motor housing as shown.
07 HANGING THE FAN

13F-069U
67
HANGING THE FAN 07
1. Align downrod and motor collar holes, re-insert pins and screws.
2. Slip up canopy and canopy screw cover. Re-install hanger ball
with cross pin in correct place.
1. Seat all into the mounting bracket. Rotate until ball drops and
locks into hanger bracket screw.

14
9Outlet Box
Hanger Ball & Downrod
8
07 HANGING THE FAN MAKING THE ELECTRICAL CONNECTIONS
1. Secure the safety cable into the structure beams using the
wood screw, washers, and spring washers provided.
2. Slide receiver facing down as shown above.
NOTE: Safety cable is required for all ceiling fan installations in
Canada. Safety cable is required for ceiling fan and light (combo)
installations over 35 lbs. in both ush and downrod models in the
United States. Use Chardware.
1. Connect the labled wires from fan to the corresponding wires
on the receiver.
2. Connect the labeled wires from the outlet box to the
corresponding wires on the receiver.
After making electrical connections, spliced connectors should be
turned upward and pushed carefully up into the outlet box. The
wires should be spread apart with the grounded conductor and the
equipment-grounding conductor on one side of the outlet box and
ungrounded connector on the other side of the outlet box. Secure
all connections with wire ties, nuts and electrical tape. Failure to do
so may result in damage to the electronics. Use Dhardware.

15F-069U
10
1. Install canopy to mounting bracket with the screw
removed in section 2
2. Twist canopy into place as shown.
3. Install canopy screw ring as shown.
FINISHING THE INSTALLATION 08

F-069U
16
1211
09 INSTALLING THE ADAPTER PLATE
1. Remove 1 of 3 screws from the mounting ring and loosen the
others (do not remove).
2. Twist and lock adapter plate into place by following the arrows
above.
3. Using the previously removed screw from the previous step,
install the adapter plate.

17F-069U
INSTALLING THE COVER 10
13
1. Install cover rmly without over-tightening.
2. Review the UV Safety Rules again before powering on your fan

F-069U
18
16
A
B
C
Your fan was delivered to you with the included remote already
paired to your fan. You will need to remove the pull-tab to begin
using your remote control.
A: UV Light On/O
B: Fan On/O, Speed Up/Down
C: Season (Summer/Winter)
NOTE: Your fan features 6 speeds. An audible tone will indicate
when the speed is increased or decreased. When the fan has
reached the minimum/maximum speed level the fan will beep
twice.
Summer Mode
(Counter-Clockwise)
Winter Mode
(Clockwise)
14 15
Pairing
Press and hold buttons
for 6 seconds.
Remote
Control
Unpairing
Disassociate a remote control
from a fan receiver, press and hold
Season Toggle and Fan Up for 4
seconds
NOTE: Pairing must be completed within 3 minutes of turning the
power on to the fan receiver. If you wish to pair your remote to another
WAC Smart Fan or if you ever need to re-pair your remote to its original
fan, press and hold the light toggle and fan toggle for 4 seconds until
you hear a short beep, long beep combination from the fan.
11 CONTROLLING THE FAN

19F-069U
CONTROLLING THE FAN 11
Controlling Multiple Fans with the Remote Control
Your remote control is capable of controlling multiple fans. A
remote control has the ability to control an unlimited number
of fans with the only limitation being the Bluetooth® range of
the control and fan.
Pairing a remote control to an additional fan(s) can be
performed in the same manner as described in the pairing
section.
NOTE: Pairing must be completed within three (3) minutes of
powering the fan.
Synchronizing Control Across Multiple Fans
If you are controlling more than one fan with a remote control,
there is a possibility that their light state, fan state or fan
direction can get out of sync. To bring the fans/lights back
into sync please follow the instructions on the next page.
Breeze Mode
1. Breeze Mode mimics the natural ebb and flow of winds in
nature by varying the fan speed.
NOTE: Breeze Mode always rotates your fan in the Summer
(CCW) direction
2. To start Breeze Mode, press and for 4 seconds. The
LED will blink green and the fan will beep.
3. To exit Breeze Mode and return to standard fan mode,
press and for 4 seconds. The led will blink green and
the fan will beep. Your fan will return to the direction and
speed it was set to prior to entering Breeze Mode.
4. Auto O Timer Feature: This feature will automatically
turn o the UV light after a xed period of time. Feature is
o by default. To enable/disable, Press and hold and for 4
seconds. The fan will beep indicating the change. Default
time: 45 minutes. Duration can be changed using the
mobile App.

F-069U
20
17
Fan On/O: Press and hold button for 4 seconds. The LED on the remote will ash green and all connected fans will beep to
indicate the message has been received. All fans will turn o. This will bring all fans controlled by the remote into sync.
Light On/O: Press and hold button for 4 seconds. The LED on the remote will ash green and all connected fans will beep to
indicate the message has been received. All lights will turn o. This will bring all fans controlled by the remote into sync.
Fan Direction: Press and hold button for 4 seconds. The LED on the remote will ash green and all connected fans will beep to
indicate the message has been received. All fans will be set to summer mode (CCW rotation). This will bring all fans controlled by the
remote into sync.
Fan On/O
Press and hold
button for 4 seconds.
UV Light On/O
Press and hold
button for 4 seconds.
Fan Direction
Press and hold
button for 4 seconds.
11 CONTROLLING THE FAN
Table of contents
Other WAC Fan manuals