3
2
4
5
6
7
1
1
2
3
6
7
5
44
Thermo Control Mode: Set a target temperature (C°/F°)
Manual Mode: Blow heat with 6 power levels (1-6).
Ventilation Mode: Blow fresh air without heating
SET OPERATION MODE
Prior to starting the heater, choose mode by using
the Arrow Buttons (left or right) to move the
orange selection square to the Main Menu Bar,
press Select Button to activate the Main Menu Bar,
use Arrow Buttons to choose the desired mode and
press the Select Button to select. To switch
between modes, turn the heater off and start in the
desired mode.
To start, use the Arrow Buttons
(left or right) to move the orange
selection square to the white
Start/Stop Icon and press the
Select Button. Confirm the
selection by holding the Select
Button down for 3 seconds (safety
feature). White icon turns orange.
Starting will appear on the screen.
The light orange combustion light
will light up when the burner flame
has been ignited and the
combustion has stabilized (in about
5 min). Heater will be fully
operational about 10 min later.
IGNITION
In Thermo Control Mode, move
the selection square to the Target
Temperature and press the Select
Button. Press Arrow Buttons (left
or right) to set the desired target
temperature.
3 0 0 8 A D V A N C E D C O N T R O L P A N E L
Main Menu Bar
Target Temperature / Power
Level / Blower Speed
Room Temperature
Heater Status
Start/Stop Icon
Air Boost Icon
Info Bar
Manual Mode
Thermo Control Mode
Ventilation Mode
Settings
Temp Sensor
Device Info
Device Stats
Clear Lock
Temp Unit (C°/F°)
Connections
Altitude
TEMPERATURE/POWER SETTING
Power On/Off
Combustion
Info
Lock
Heater power %
Select
Button
Left Arrow
Move cursor
left or up
Right Arrow
Move cursor
right or down
In Manual Mode, move the
selection square to the Power
Level and press the Select
Button. Use Arrow Buttons to
set the desired power level (1-6).
Digital Panel Legend
(MAIN MENU BAR)
OPERATION GUIDE
V i k i n g S e r i e s , S p a r t a n S e r i e s
Please Refer to Manual for Full Operation and Maintenance Instructions at wallas.com
AIR BOOST
Use Arrow Buttons
to move the selector
to the Air Boost icon
and press the Select
Button.
The orange Air Boost
On icon will appear.
Ventilation Mode blows fresh air without
heating with 6 blower speeds. Choose
Ventilation Mode prior to starting the heater.
VENTILATION MODE
Pause Mode automatically turns the heater off if the
temperature remains +2 C (3 F) above the set level
for 1/2 hour due to local ambient conditions.
Pause Mode can be turned off temporarily by slightly
increasing the target temperature.
PAUSE MODE
If the heater is in Pause Mode,
Paused and a Pause Icon will appear
on the screen.
Heater will re-start heating again
automatically, if the cabin
temperature falls 2 degrees C (3 F)
below the set target temperature.
Air Boost feature maximizes the air volume for quick
defrosting and drying, but does not change the set
temperature. Air Boost can be activated either in Manual
or Thermo Control Mode, when the system is heating.
To go back to normal
air volume, choose
the Air Boost icon
again and press the
Select Button. The
Air Boost icon will
change back to white.
Use the Arrow Buttons to move
the selection square to the Main
Menu Bar and press the Select
Button to activate it.
Use Arrow Buttons to choose
Ventilation Mode and press the
Select Button.
Move the selection square to the
Start/Stop Icon and press the
Select Button once. Press the
Select Button down again for 3
seconds to confirm and start the
heater. Yellow Power On light
will appear in the Info Bar.
Choose the blower speed
(1-6) by moving the selection
square to the Blower Speed and
press Select Button to activate
the field.
Press Arrow Buttons to set the
desired power and press the
Select Button to choose.
To deactivate ventilation, turn
the heater off. Re-start in the
desired mode.
(IN THERMO CONTROL MODE)
If a Lock Icon is displayed, the
heater has locked itself for safety.
The heater will also lock after 2
unsuccessful starts. Move the
selection square to the
Exclamation Point Icon and press
the Select Button. An Error Page
will appear.
LOCK
If the heater has locked itself,
there may have been a failure
that should be investigated and
resolved prior to further use. The
error page will display a check list
and a website for further
information. If you need help,
reach out to a professional.
(SAFETY FEATURE)
Press and hold the Select Button
down for more than 4 seconds.
Stopping will appear and the
Power Icon light will change to
white indicating the unit is off.
SHUTDOWN
Note: The system mode that was used last upon
shutdown will be the same mode when the heater
is turned on again. To remove the lock, press any
button to return to the main display.
Move the selection square to the
Main Menu Bar and press the
Select Button, choose Settings, and
press the Select Button. Choose
Clear Lock from the Settings Menu
and press the Select Button.
Select
Button
All rights reserved. Wallas-Marin reserves the right to change or improve its products and to make changes in the content of this guide
without obligation to notify any person or organization of such changes or improvements. Go to www.wallas.com for current updates and
supplemental information concerning the use of this product.

Other manuals for 3008

4

Other wallas Control Panel manuals

wallas PI Thermo User manual

wallas

wallas PI Thermo User manual

wallas 3008 User manual

wallas

wallas 3008 User manual

wallas 3007 User manual

wallas

wallas 3007 User manual

wallas 3008 User manual

wallas

wallas 3008 User manual

wallas 85 DT User manual

wallas

wallas 85 DT User manual

wallas 3008 User manual

wallas

wallas 3008 User manual

wallas PI User manual

wallas

wallas PI User manual

wallas 3008 User manual

wallas

wallas 3008 User manual

Popular Control Panel manuals by other brands

Bticino 352500 manual

Bticino

Bticino 352500 manual

MCZ MAESTRO 4021004 installation guide

MCZ

MCZ MAESTRO 4021004 installation guide

jablotron Oasis JA-80 installation manual

jablotron

jablotron Oasis JA-80 installation manual

Haes ESG-2001 Installation, commissioning & operating  manual

Haes

Haes ESG-2001 Installation, commissioning & operating manual

Honeywell Domonial CMI Series Installer manual

Honeywell

Honeywell Domonial CMI Series Installer manual

Slate Raven MTX2 manual

Slate

Slate Raven MTX2 manual

NAPCO Gemini GEM-P9600 Programming instructions

NAPCO

NAPCO Gemini GEM-P9600 Programming instructions

Amphenol GMT Series user manual

Amphenol

Amphenol GMT Series user manual

Ceiva Homeview Display Installing

Ceiva

Ceiva Homeview Display Installing

FM Electronics FM4000X installation instructions

FM Electronics

FM Electronics FM4000X installation instructions

Ross Ultricore RCP-ME user guide

Ross

Ross Ultricore RCP-ME user guide

Interlogix Concord 4 RF installation guide

Interlogix

Interlogix Concord 4 RF installation guide

Leviton 400CP Installation & operation guide

Leviton

Leviton 400CP Installation & operation guide

S&S Northern Merlin 2000X Installation & operation manual

S&S Northern

S&S Northern Merlin 2000X Installation & operation manual

Controls HARLO MVP-902 product manual

Controls

Controls HARLO MVP-902 product manual

Balboa ML900 user guide

Balboa

Balboa ML900 user guide

Veris HAWKEYE 5002 Installation instructions manual

Veris

Veris HAWKEYE 5002 Installation instructions manual

IntelliSense SECURIT 900C user manual

IntelliSense

IntelliSense SECURIT 900C user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.