REV DESCRIPTION INT: REV. DATE APPROVED
1 ECO# CO2557 MJS
TITLE BOX PAGE ONLY.
DO NOT MAKE FILM • DO NOT PRINT
MATERIAL: White 16lb (60g/m sq) uncoated, prefer recycled stock
Ink: Black
Print Two Sides, one sheet
Final Trim Size: 8.5” (Wide) x 11” (High)
IF YOU HAVE ANY QUESTIONS REGARDING SPECIFICATIONS OR REQUIRE
ADDITIONAL FILE FORMATTING, PLEASE CONTACT Mary Jo Sowinski.
Phone: 408-486-7511
Email: maryjo.sowinski@wattstopper.com
All information in this drawing is the property of Watt Stopper/Legrand
and cannot be copied or used without the written approval of
Watt Stopper/Legrand.
Title: FM-105Installation Instructions
SANTA CLARA, CALIFORNIA
DRAWN BY
PLM
MARCOM
ENGINEERING
QA
TITLE BOX PG
SOWINSKI
SCALE 1:1
Drawing #:
08745
Orig. Drawing Date: 27 MAR 08
Revision Date:
REV. #:
1
FM-105
Line Voltage • Microwave
Occupancy Sensor
Installation Instructions
DESCRIPTION AND OPERATION
The FM-105 microwave occupancy sensor uses ultra-high-
frequency radio waves, also known as “microwaves” and
the principle of the Doppler Effect to detect motion. The
sensor sends out radio waves that bounce off of nearby
surfaces and return to the sensor. Motion in the area
changes the speed of the waves returning to the sensor. The
sensor detects the change and interprets it as occupancy.
This causes the sensor to turn ON the load.
Microwaves can penetrate certain materials, therefore,
the FM-105 can be installed behind a luminaries’ plastic or
glass lens.
The FM-105 can be used in a water-tight non-metallic box
or water-tight luminaire for wet location applications.
Daylighting Control
The FM-105 also has daylighting control capability. The
daylight control on the FM-105 is a “HOLD-OFF” type. The
sensor stops the load from turning ON if the ambient light
is greater than the daylighting setpoint. If the load is already
ON, the sensor will not turn OFF the load due to high
ambient daylight.
SENSOR COVERAGE AREA
Wall Mount
6’ (2m)
12’ (4m)
18’ (5.5m)
MAX.
20’ (6m)
MIN.
3’ (1m)
Ceiling Mount
6’ (2m)
12’ (4m)
18’ (5.5m)
MAX.
MIN.
FM-105
inside
ceiling mount
fixture
at 8’ (2.5m)
height
Call 800.879.8585 for Technical Support www.wattstopper.com
FM-105 with shield and mounting foot
SPECIFICATIONS
Voltages.......................................... 120/277VAC, 50/60Hz
Load Requirements
@ 120VAC, 60Hz.................0-800W ballast or tungsten
@ 277VAC, 60Hz...................................0-1200W ballast
Trimpot Adjustments
Light Level.........................................................2-200fc
Range/Sensitivity ...........................3’ to 20’ (1m to 6m)
Time Delay ...........................10 seconds to 30 minutes
Power Output ... 1 mW (similar or less than a cell phone)
Frequency.............................................................. 5.8GHz
INSTALLATION
CAUTION
TURN THE POWER OFF AT THE
CIRCUIT BREAKER BEFORE
INSTALLING THE SENSOR.
1. Determine the mounting location inside the luminaire
or other suitable enclosure. If the daylight feature will
be used, be sure to locate the sensor where daylight is
not completely obscured from the sensor.
2. Attach the metal shield to the FM-105 so that the
shield is located between the FM-105 and the lamp.
Make sure that the wiring terminals on the FM-105 are
accessible.
3. Put the plastic mounting foot onto the base of the
FM-105 to secure the metal shield in place.
4. Secure the FM-105 assembly in place using screws
through the plastic mounting foot.
5. Connect the line voltage and load wires to the FM-105
terminals as shown in the wiring diagram.
• Do not allow bare wire to show.
• Make sure all connections are secure.
6. Restore power from the circuit breaker.
WIRING
10
sec 30 min
3’ 20’
1200
Time Delay
Light Level
(footcandles)
Range (feet)
31220
LOAD
NEUT
LINE
Plastic mounting foot
Lighting
Load Metal
shield
Hot/Line
Neutral
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
@277VAC: 0-1200W Ballast
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
MOUNTING OPTIONS
Position metal shield between the FM-105 and lamp.
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
0-600W Tungsten,
1/6 hp
@277VAC: 0-1000W Ballast,
1/4 hp
FCC ID: Q4BFM105
10
sec 30 min
3’ 20’
1200
Time Delay
Light Level
(footcandles)
Range (feet)
31220
LOAD
NEUT
LINE
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
@277VAC: 0-1200W Ballast
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
Bottom of FM-105: Align studs on the
bottom of the FM-105 with the holes on
the metal shield flanges. Do not block
wiring terminals on the FM-105 with the
shield.
The mounting foot provides 4 different
mounting positions.
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
0-600W Tungsten,
1/6 hp
@277VAC: 0-1000W Ballast,
1/4 hp
FCC ID: Q4BFM105
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
0-600W Tungsten,
1/6 hp
@277VAC: 0-1000W Ballast,
1/4 hp
FCC ID: Q4BFM105
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
0-600W Tungsten,
1/6 hp
@277VAC: 0-1000W Ballast,
1/4 hp
FCC ID: Q4BFM105
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
0-600W Tungsten,
1/6 hp
@277VAC: 0-1000W Ballast,
1/4 hp
FCC ID: Q4BFM105
10
sec 30 min
3’ 20’
1200
Time Delay
Light Level
(footcandles)
Range (feet)
31220
LOAD
NEUT
LINE
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
@277VAC: 0-1200W Ballast
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
10
sec 30 min
3’ 20’
1200
Time Delay
Light Level
(footcandles)
Range (feet)
31220
LOAD
NEUT
LINE
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
@277VAC: 0-1200W Ballast
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
10
sec 30 min
3’ 20’
1200
Time Delay
Light Level
(footcandles)
Range (feet)
31220
LOAD
NEUT
LINE
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
@277VAC: 0-1200W Ballast
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
10
sec 30 min
3’ 20’
1200
Time Delay
Light Level
(footcandles)
Range (feet)
31220
LOAD
NEUT
LINE
FM-105
Microwave
(5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
@277VAC: 0-1200W Ballast
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
Mounting foot: Align 4 corner studs on the bottom of the
FM-105 with 4 corner slots on mounting foot. Twist to secure.
ADJUSTMENTS
Three trimpots on the FM-105 allow you to
adjust the time delay, sensitivity/range, and
light level setpoint. To reduce a setting, turn
the associated trimpot counter-clockwise
toward the minimum setting. To increase a
setting, turn the trimpot clockwise toward
the maximum setting.
Warning: Do not overturn the adjustment trimpots!
Time Delay
The FM-105 automatically turns OFF the load after the coverage
area has been vacant for the amount of time set in the time delay.
The minimum setting is 10 seconds, maximum is 30 minutes.
Call 800.879.8585 for Technical Support • www.wattstopper.com
Range/Sensitivity
It is possible for a microwave sensor to “see” through solid
objects and detect motion if the sensitivity is set too high. If you
are getting detections and the load will not turn OFF, reduce the
sensitivity slightly and see if that corrects the situation.
Light Level
Adjust the daylighting setpoint when ambient light is sufficient
to keep the lights OFF. Set the time delay to minimum. Adjust
the light level trimpot in small increments. Wait 1 to 2 minutes
between adjustments. After the time delay expires and the load
turns OFF, move within the detection area of the sensor. If the
load comes back ON, you need to repeat the procedure.
IMPORTANT STARTUP INFORMATION
The first time the sensor is powered-up the load will flash ON
then OFF once, then there will be 10 seconds while the sensor
warms-up. After that time the sensor will work normally.
TROUBLESHOOTING
To quickly test the unit, turn the time delay to minimum. Move
out of the sensor’s view. Lights should turn OFF after 10 seconds.
Move into the sensor’s view. The lights should turn ON.
Lights do not turn ON:
1. Cover the sensor to simulate darkness then move in the
coverage area. If the load turns ON, adjust the light level.
2. Check all wire connections. Verify all wires are secure.
Lights do not turn OFF:
1. If there is no motion in the desired coverage area, the
sensor may be picking up movement on the other side of
a wall, partition, window or door. Reduce the sensitivity.
2. Verify time delay and that there is no movement
within the sensor’s view for that time period.
FCC NOTICE FCC ID: Q4BFM105
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Caution: Any changes or modifications to this device not
explicitly approved by Watt Stopper/Legrand could void your
authority to operate this equipment.
OR
WARRANTY INFORMATION
Watt Stopper/Legrand warranties its products to be free of
defects in materials and workmanship for a period of five (5)
years. There are no obligations or liabilities on the part of Watt
Stopper/Legrand for consequential damages arising out of, or in
connection with, the use or performance of this product or other
indirect damages with respect to loss of property, revenue or
profit, or cost of removal, installation or reinstallation.
2800 De La Cruz Boulevard, Santa Clara, CA 95050
08745r1 3/2008
Please
Recycle

Other wattstopper Accessories manuals

wattstopper WS-301 Service manual

wattstopper

wattstopper WS-301 Service manual

wattstopper Legrand LMPC-100 User manual

wattstopper

wattstopper Legrand LMPC-100 User manual

wattstopper W-500A User manual

wattstopper

wattstopper W-500A User manual

wattstopper CX-100 User manual

wattstopper

wattstopper CX-100 User manual

wattstopper UT-300-1 User manual

wattstopper

wattstopper UT-300-1 User manual

wattstopper LMDC-100 User manual

wattstopper

wattstopper LMDC-100 User manual

wattstopper CD-250 User manual

wattstopper

wattstopper CD-250 User manual

wattstopper DSW-301 User manual

wattstopper

wattstopper DSW-301 User manual

wattstopper EW-205-24 User manual

wattstopper

wattstopper EW-205-24 User manual

wattstopper LMDC-100 User manual

wattstopper

wattstopper LMDC-100 User manual

wattstopper CI-200 User manual

wattstopper

wattstopper CI-200 User manual

wattstopper PW-301 User manual

wattstopper

wattstopper PW-301 User manual

wattstopper CI-300 User manual

wattstopper

wattstopper CI-300 User manual

wattstopper UT-305 User manual

wattstopper

wattstopper UT-305 User manual

wattstopper DT-200 User manual

wattstopper

wattstopper DT-200 User manual

wattstopper DT-305 User manual

wattstopper

wattstopper DT-305 User manual

wattstopper DSW-301 User manual

wattstopper

wattstopper DSW-301 User manual

wattstopper DT-355 User manual

wattstopper

wattstopper DT-355 User manual

wattstopper FSP-211 User manual

wattstopper

wattstopper FSP-211 User manual

wattstopper EW-100-120 User manual

wattstopper

wattstopper EW-100-120 User manual

wattstopper DT-300 User manual

wattstopper

wattstopper DT-300 User manual

wattstopper PW-100 User manual

wattstopper

wattstopper PW-100 User manual

wattstopper CI-24 User manual

wattstopper

wattstopper CI-24 User manual

wattstopper CI-200 User manual

wattstopper

wattstopper CI-200 User manual

Popular Accessories manuals by other brands

Tobii Pro Nano user manual

Tobii Pro

Tobii Pro Nano user manual

horiba 0030-10D instruction manual

horiba

horiba 0030-10D instruction manual

Orno OR-AE-1304 Operating and installation instructions

Orno

Orno OR-AE-1304 Operating and installation instructions

Cub VS-60U024 Series manual

Cub

Cub VS-60U024 Series manual

Voksi Design by Voksi user manual

Voksi

Voksi Design by Voksi user manual

Honeywell SHK8M installation instructions

Honeywell

Honeywell SHK8M installation instructions

Seeley Climate Wizard CW-P15 Installation operation & maintenance

Seeley

Seeley Climate Wizard CW-P15 Installation operation & maintenance

CEL-MAR DES-300E user manual

CEL-MAR

CEL-MAR DES-300E user manual

Clearaudio Unify user manual

Clearaudio

Clearaudio Unify user manual

Banner WORLD-BEAM Expert QS18E Series instruction manual

Banner

Banner WORLD-BEAM Expert QS18E Series instruction manual

Modine Manufacturing ECO MODINE MIC Technical manual

Modine Manufacturing

Modine Manufacturing ECO MODINE MIC Technical manual

Zephyr PRB24C01BPG Use, care and installation guide

Zephyr

Zephyr PRB24C01BPG Use, care and installation guide

Innovative Technology Justin JP-140-3000i user manual

Innovative Technology

Innovative Technology Justin JP-140-3000i user manual

NAPCO CF5530 installation instructions

NAPCO

NAPCO CF5530 installation instructions

Pro-Ject Audio Systems Dock Box F Instructions for use

Pro-Ject Audio Systems

Pro-Ject Audio Systems Dock Box F Instructions for use

Laird Sentrius BT610 user guide

Laird

Laird Sentrius BT610 user guide

Osprey SYNCRO 20 owner's manual

Osprey

Osprey SYNCRO 20 owner's manual

Drop massdrop x MEE audio Welcome guide

Drop

Drop massdrop x MEE audio Welcome guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.