Weller WFE 2ES User manual

EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
WFE 2ES
Betriebsanleitung
DE

WFE 2ES
WFE 2ES
Geräteübersicht
1 Öffnung für Abluft
2 Filtergehäuse
3 Rohrstutzen
Vakuumanschluss
4 Spannschlösser
5 Netzschalter
6 Sicherung
7 Netzanschluss
8 Turbinengehäuse
9 Verschlussstopfen
10 Feinstaubfilter
11 Kompaktfilter
12 Turbinenplatte
10
11
12
8
2

WFE 2ES 3-8
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Inhalt
1Zu dieser Anleitung .................................................................... 3
2Zu Ihrer Sicherheit ..................................................................... 4
3Lieferumfang WFE 2ES ............................................................. 4
4Gerätebeschreibung .................................................................. 5
5Gerät in Betrieb nehmen ............................................................ 5
6Lötrauch absaugen .................................................................... 6
7Filter wechseln ........................................................................... 7
8Fehlermeldungen und Fehlerbehebung..................................... 8
9Zubehör ..................................................................................... 8
10 Entsorgung ................................................................................ 8
11 Garantie ..................................................................................... 8
1Zu dieser Anleitung
Wir danken Ihnen für das mit dem Kauf der Weller WFE 2ES
erwiesene Vertrauen. Bei der Fertigung wurden strengste
Qualitätsanforderungen zugrunde gelegt, die eine einwandfreie
Funktion des Gerätes sicherstellen.
Diese Anleitung enthält wichtige Informationen, um die
Lötrauchabsaugung WFE 2ES sicher und sachgerecht in Betrieb zu
nehmen, zu bedienen, zu warten und einfache Störungen selbst zu
beseitigen.
ZLesen Sie diese Anleitung und die beiliegenden
Sicherheitshinweise vor Inbetriebnahme des Gerätes vollständig
bevor Sie mit der Lötrauchabsaugung WFE 2ES arbeiten.
ZBewahren Sie diese Anleitung so auf, dass sie für alle Benutzer
zugänglich ist.
1.1 Berücksichtigte Richtlinien
Die Weller Lötrauchabsaugung WFE 2ES entspricht den Angaben
der EG Konformitätserklärung mit den Richtlinien 2004/108/EG und
2006/95/EG.
1.2 Mitgeltende Dokumente
−Betriebsanleitung der Lötrauchabsaugung WFE 2ES
−Begleitheft Sicherheitshinweise zu dieser Anleitung

4-8 WFE 2ES
2Zu Ihrer Sicherheit
Die Lötrauchabsaugung WFE 2ES wurde entsprechend dem
heutigen Stand der Technik und den anerkannten
sicherheitstechnischen Regeln hergestellt. Trotzdem besteht die
Gefahr von Personen- und Sachschäden, wenn Sie die
Sicherheitshinweise im beiliegenden Sicherheitsheft sowie die
Warnhinweise in dieser Anleitung nicht beachten. Geben Sie die
Lötrauchabsaugung WFE 2ES an Dritte stets zusammen mit der
Betriebsanleitung weiter.
2.1 Bestimmungsgemäßer Gebrauch
Verwenden Sie die Lötrauchabsaugung WFE 2ES ausschließlich
gemäß dem in der Betriebsanleitung angegebenen Zweck der
Lötrauchabsaugung von Arbeitsflächen unter den hier angegebenen
Bedingungen. Der bestimmungsgemäße Gebrauch der
Lötrauchabsaugung WFE 2ES schließt auch ein, dass
−Sie diese Anleitung beachten,
−Sie alle weiteren Begleitunterlagen beachten,
−Sie die nationalen Unfallverhütungsvorschriften am Einsatzort
beachten.
Für eigenmächtig vorgenommene Veränderungen am Gerät wird
vom Hersteller keine Haftung übernommen.
3Lieferumfang WFE 2ES
−WFE 2ES inkl. Filter
−Anschlusskabel
−Betriebsanleitung
−Heft Sicherheitshinweise

WFE 2ES 5-8
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
4Gerätebeschreibung
Die Weller WFE 2ES ist eine Lötrauchabsaugung für den Einsatz als
Arbeitsflächenabsaugung für folgende Eigenschaften und
Funktionen konzipiert:
−Sie besitzt eine leistungsstarke wartungsfreie Turbine und ist
bestens geeignet für den industriellen Dauerbetrieb.
−Individuelle Gestaltung des Rohrsystems mit max. 2 Rohrstutzen.
−3-Stufen-Filter (Feinstaub-, Schwebstoff- und Aktivkohlefilter)
abgestimmt auf die standardmäßige Zusammensetzung von
Lötrauch.
−Hohe Filtereffizienz: Beim Einsatz von geprüften
Schwebstofffiltern der Klasse E12 liegt nach EN 1822 der
Abscheidgrad des Filtersatzes im Auslieferzustand bei 99,5 %, bei
einer Partikelgröße von 0,18 µm (Werte gelten nur bei Benutzung
von Orginalteilen).
4.1 Technische Daten WFE 2ES
A
bmessungen L x B x H (mm): 320 x 320 x 395
Gewicht 9 kg
Spannung 230 V, 50Hz
120 V, 60 Hz
Elektr. Leistung 115 VA
Max. Vakuum 1800 Pa
Max. Fördermenge 220 ㎥
/
h
Feinstaubfilter Stufe 1: Feinstaubfilter M5 nimmt 40-60 %
Feinstaub > 1 mm au
f
.
Kompaktfilter Stufe 2+3: Schwebstofffilter Klasse E12
(99,5 % bei Partikel bis ca. 0,18 µm) ist
kombiniert mit einem Aktivkohlefilte
r
.
5Gerät in Betrieb nehmen
Achten Sie beim Aufstellen des Gerätes darauf, dass die Abluft
ungehindert aus der Abluftöffnung befördert werden kann.
1. Das Gerät sorgfältig auspacken.
2. Lötrauchabsaugung WFE 2ES über einen
- flexiblen Absaugschlauch
oder
- direkt mit dem Vakuumrohrsystem verbinden.
3. Vor Inbetriebnahme Netzspannung mit der Angabe auf dem
Typschild überprüfen.
4. Bei korrekter Netzspannung das WFE 2ES mit dem Netz
verbinden.
5. Gerät am Netzschalter (7) einschalten.

6-8 WFE 2ES
6Lötrauch absaugen
WARNUNG!
Giftige Gase
Der Unterdruck des WFE 2ES ist für die Direktabsaugung nicht
ausreichend. Beim Löten entstehen giftige Gase welche
ungefiltert zu Gesundheitsschäden führen.
ZVerwenden Sie das WFE 2ES nur zur
Flächenlötrauchabsaugung.
Löten oder Schweißen von Lackdrähten
Verwenden Sie beim Löten und Schweißen von Lackdrähten die
standardmäßige Filtermatte M5 und einen Feinstaubfilter der
Klasse F7.
Absaugen von Klebedämpfen
Verwenden Sie beim Absaugen von Klebedämpfen einen
Breitbandgasfilter (ohne Schwebestofffilter).
Absaugen beim Löten und Schweißen
1. Filter auf Eignung und Einsatzfähigkeit überprüfen.
2. Absaugschlauch am Vakuumanschluss (3) des WFE 2ES
anschließen.
3. Absaugschlauch positionieren und fixieren.
4. WFE 2ES einschalten und absaugen.
WARNUNG!
Selbstentzündung der Aktivkohle
Durch hohe Schadgaskonzentration kann es zu einer starken
Erwärmung der Aktivkohle kommen, die zur Selbstentzündung
des Filters führen kann.
ZBetreiben Sie das Gerät vor dem Abschalten für mehrere
Minuten mit schadgasfreier Luft.
5. Nach dem abgeschlossenen Löt-/Klebevorgang
Gerät 5 min schadgasfrei betreiben.
6. Gerät abschalten

WFE 2ES 7-8
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
7Filter wechseln
WARNUNG!
Ungefilterte Schadstoffe und Gase
Ein übersättigter Aktivkohlefilter nimmt keine Schadstoffe und
Gase mehr auf. Die Gase und Schadstoffe werden ungefiltert
wieder an die Umgebung abgegeben.
ZHalten Sie die empfohlenen Filterwechselintervalle ein.
Hinweis Verschiedene Flussmittel, Flussmittelanteile sowie
unterschiedliche Staubanteile der abgesaugten Luft können die
Lebensdauer des Filters wesentlich reduzieren.
Deshalb müssen Sie regelmäßig den Filter überprüfen und ggf.
wechseln.
Empfehlung zum Filterwechsel:
ZBei Einschicht Betrieb den Vorfilter (=Feinstaubfilter) alle 10
Tage überprüfen und bei starker Verunreinigung auswechseln.
ZKompaktfilter nach dem 6. – 8. Vorfilterwechsel austauschen.
Filter ausbauen:
1. Netzstecker (7) vom Netz trennen.
2. Spannschlösser (4) zwischen Turbinengehäuse (8) und
Filtergehäuse (2) öffnen.
3. Filtergehäuse (2) abheben.
4. Verunreinigten Feinstaubfilter (10) aus Kompaktfilter (11)
entnehmen
oder
Verunreinigten Kompaktfilter (11) entnehmen.
Hinweis Entsorgen Sie die verschmutzten Filter als Sondermüll nach den
Vorschriften des Verwendungslandes.
Neuen Filter einbauen:
5. Kompaktfilter (11) einlegen (Durchflussrichtung beachten).
6. Feinstaubfilter (10) in den Kompaktfilter (11) einlegen.
7. Filtergehäuse (2) schließen
8. Spannschlösser (4) schließen.
9. Datum des Filterwechsels auf Wartungslabel notieren und am
Gehäuse gutsichtbar anbringen.
10. Netzstecker (7) einstecken.
Das Gerät ist nun wieder betriebsbereit.

8-8 WFE 2ES
8Fehlermeldungen und Fehlerbehebung
Störung Mögliche Ursache Maßnahmen zur Abhilfe
Fehlende Absaugleistung −Rohrsystem undicht
−Filter verschmutzt
−Rohrsystem abdichten
−Filter wechseln
WFE 2ES läuft nicht an −Thermische Abschaltung −WFE 2ES abkühlen lassen
−Nach ca. 3h wieder einschalten
Schwebstofffilter zu schnell
verschmutzt
−Kein Vorfilter eingesetzt −Vorfilter einsetzen
−F7 Filter einsetzen
−Vorabscheider einsetzen (bei
hohem Feststoffanteil)
9Zubehör
T005 36 571 99 Set KIT1WF Trichter für WFE 2 Flächenabsaugung
T005 36 572 99 Set KIT1WF Düsen für WFE 2 Flächenabsaugung
T005 87 358 62 Filtergehäuse
T005 87 627 53 WFE Adapter 50-60 mm
T005 87 627 56 Absaugschlauch flexible Ø 60 (5 m)
T005 87 627 01 Filterset E12 mit 10 Vorfilter M5
besteht aus: EPA Filter E12, Breitbandgasfilter
(10 % Aktivkohle)
T005 87 627 03 Feinstaubfilter M5 (10 St.)
T005 87 627 04 Gehäuseoberteil
Feinstaubfilter für Kompaktfilter
T005 87 359 36 Kompaktfilter EPA E12+Gasfilter
T005 87 359 37 Feinstaubfilter M5 (10 St.)
T005 87 359 38 Feinstaubfilter F7 (10 St.)
10 Entsorgung
Entsorgen Sie ausgetauschte Geräteteile, Filter oder alte Geräte
gemäß den Vorschriften Ihres Landes.
11 Garantie
Die Mängelansprüche des Käufers verjähren in einem Jahr ab
Ablieferung an ihn. Dies gilt nicht für Rückgriffsansprüche des
Käufers nach §§ 478, 479 BGB.
Aus einer von uns abgegebenen Garantie haften wir nur, wenn die
Beschaffenheits- oder Haltbarkeitsgarantie von uns schriftlich und
unter Verwendung des Begriffs „Garantie“ abgegeben worden ist.
Technische Änderungen vorbehalten!
Die aktualisierten Betriebsanleitungen finden Sie unter
www.weller-tools.com.

EN
FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
WFE 2ES
Operating instructions

WFE 2ES
WFE 2ES
Equipment overview
1 Opening for exhaust air
2 Filter housing
3 Vacuum connection pipe
nozzle
4 Turnbuckles
5 Mains switch
6 Fuse
7 Mains connection
8 Turbine housing
9 Bung
10 Fine dust filter
11 Compact filter
12 Turbine plate
10
11
12
8
2

WFE 2ES 3-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Contents
1About these instructions ............................................................ 3
2For your safety ........................................................................... 4
3Scope of delivery WFE 2ES ...................................................... 4
4Device description ..................................................................... 5
5Starting up the device ................................................................ 5
6Extracting soldering smoke ........................................................ 6
7Changing filter ............................................................................ 7
8Fault messages and fault elimination ........................................ 8
9Accessories ............................................................................... 8
10 Disposal ..................................................................................... 8
11 Warranty .................................................................................... 8
1About these instructions
Thank you for placing your trust in our company by purchasing the
Weller WFE 2ES. Production was based on stringent quality
requirements which guarantee the perfect operation of the device.
These instructions contain important information for safe and correct
initial operation of the soldering fume extraction device WFE 2ES,
including continued operation, maintenance and self-correction of
simple faults.
ZRead this Operating Manual and the enclosed Safety Instructions
completely prior to initial operation of the device and before
starting work with the soldering fume extraction device WFE 2ES.
ZEnsure that these instructions are accessible to all users.
1.1 Applied directives
The Weller soldering fume extraction device WFE 2ES complies with
the specifications of the EC Declaration of Conformity based on
Directives 2004/108/EC and 2006/95/EC.
1.2 Further applicable documentation
−Operating instructions for the soldering fume extraction
device WFE 2ES
−Safety information booklet accompanying these instructions

4-8 WFE 2ES
2For your safety
The soldering fume extraction device WFE 2ES has been
manufactured in accordance with state-of-the-art technology and the
recognised technical safety regulations. There is nevertheless the
risk of personal injury and damage to property if you fail to observe
the safety information set out in the accompanying booklet and the
warnings given in these instructions. If the soldering fume extraction
device WFE 2ES is passed on to third parties, always hand over the
operating instructions as well.
2.1 Specified use
Always use the soldering fume extraction device WFE 2ES
exclusively for the purpose specified in these operating instructions,
namely the soldering fume extraction from working surfaces under
the conditions specified here. Specified use of the soldering fume
extraction device WFE 2ES also includes
−observance of this Operating Manual,
−you read and follow all additional accompanying documents,
−observance of the locally applicable accident prevention
regulations.
The manufacturer shall not be liable for damage resulting from
unauthorised alterations to the machine.
3Scope of delivery WFE 2ES
−WFE 2ES incl. filter
−Connecting cable
−Operating instructions
−Safety information booklet

WFE 2ES 5-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
4Device description
The Weller WFE 2ES is designed as a soldering fume extraction
device for working surface extraction for the following properties and
functions:
−It has a powerful maintenance-free turbine and is perfectly
suitable for continuous operation in industry.
−Individual arrangement of the pipe system with max. 2 pipe
nozzles.
−3-stage filter (fine dust, EPA filter and activated carbon filter)
tuned to the standard composition of soldering smoke.
−High filter efficiency: when using tested EPA filters of class E12,
according to EN 1822 the filtration efficiency of the filter set in
delivery condition is 99.5 %, at a particle size of 0.18 µm (values
apply only if original parts are used).
4.1 Technical data WFE 2ES
Dimensions L x W x H (mm): 320 x 320 x 395
Weight 9 kg
Voltage 230 V, 50 Hz
120 V, 60 Hz
Electr. powe
r
115 VA
Max. vacuum 1800 Pa
Max. conveying
capacity
220 ㎥/h
Fine dust filter Stage 1: fine dust filter M5 absorbs
40-60 % fine dust > 1 mm.
Compact filter Stages 2+3: EPA filter class E12 (99.5 %
with particle up to approx. 0.18 µm) is
combined with an activated carbon filter.
5Starting up the device
When installing the device, ensure that the exhaust air can be
conveyed unobstructed out of the exhaust air opening.
1. Carefully unpack the device.
2. Connect the soldering fume extraction device WFE 2ES using a
- flexible extraction hose
or
- directly with the vacuum pipe system.
3. Prior to commissioning, check that the mains voltage matches the
specifications on the nameplate.
4. If the mains voltage is correct, connect the WFE 2ES to the
mains.
5. Switch on the device at the mains power switch (7).

6-8 WFE 2ES
6Extracting soldering smoke
WARNING!
Toxic gases
The vacuum of the WFE 2ES is insufficient for direct extraction.
Toxic gases are created when soldering, which can be harmful to
health if not filtered.
ZOnly use the WFE 2ES for surface soldering smoke extraction.
Soldering or welding enamel-covered wires
When soldering or welding enamel-covered wires, use the standard
filter mat M5 and a class F7 fine dust filter.
Extraction of adhesive vapours
When extracting adhesive vapours, use a wide band gas filter
(without HEPA filter).
Extraction during soldering and welding
1. Check filter for suitability and utilisability.
2. Connect extraction hose to vacuum connection (3) of the
WFE 2ES.
3. Position and secure extraction hose.
4. Switch on WFE 2ES and start extraction.
WARNING!
Auto-ignition of the activated carbon
A high concentration of noxious gas can result in considerable
heating of the activated carbon, which can lead to auto-ignition of
the filter.
ZBefore switching off, run the unit for several minutes with air
free of noxious gas.
5. When the soldering/adhesion process is complete,
run the unit for 5 minutes free of noxious gas.
6. Shut down unit

WFE 2ES 7-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
7Changing filter
WARNING!
Unfiltered harmful substances and gases
A supersaturated activated carbon filter cannot absorb any more
harmful substances and gases. The gases and harmful
substances are released again unfiltered to the environment.
ZObserve the recommended filter change intervals.
Note Different fluxes, flux concentrations and different dust
concentrations in the extracted air can considerably reduce the
service life of the filter.
The filter must therefore be inspected regularly and replaced if
necessary.
Recommendation for filter change:
ZIn single-shift operation, check the pre-filter (=fine dust filter)
every 10 days and replace if badly contaminated.
ZReplace the compact filter after the 6th to 8th pre-filter change.
Removing filter:
1. Disconnect the mains plug (7) from the mains power supply.
2. Open the turnbuckles (4) between the turbine housing (8) and
filter housing (2).
3. Lift up the filter housing (2).
4. Remove the contaminated fine dust filter (10) from the compact
filter (11)
or
remove the contaminated compact filter (11).
Note Dispose of the contaminated filter as hazardous waste in
accordance with the specifications in the country of use.
Installing new filter:
5. Insert compact filter (11) (observe flow direction).
6. Insert fine dust filter (10) in compact filter (11).
7. Close filter housing (2).
8. Close turnbuckles (4).
9. Note date of filter replacement on maintenance label and affix on
housing in clearly visible position.
10. Insert mains plug (7).
The unit is now ready for operation again.

8-8 WFE 2ES
8Fault messages and fault elimination
Fault Possible cause Corrective measures
No extraction capability −Pipe system leaking
−Filter contaminated
−Seal pipe system
−Change filte
r
WFE 2ES does not start up −Thermal cut-off −Allow the WFE 2ES to cool
down
−Switch on again after approx. 3h
HEPA filter contaminated too
quickly
−No pre-filter inserted −Insert pre-filter
−F7 Insert pre-filter
−Insert pre-separator (with high
solids content)
9Accessories
T005 36 571 99 KIT1WF for WFE 2 surface extraction
T005 36 572 99 KIT1WF for WFE 2 surface extraction
T005 87 358 62 Filter housing
T005 87 627 53 WFE adaptor 50-60 mm
T005 87 627 56 Extraction hose, Ø. 60 (5 m)
T005 87 627 01 E12 filter set with 10 M5 prefilters
comprising: E12 EPA filter, wide band gas filter
(10 % activated charcoal)
T005 87 627 03 Fine dust filter M5 (10 pieces)
T005 87 627 04 Housing upper section
Fine dust filter for Compact filter:
T005 87 359 36 E12 EPA compact filter +gas filter
T005 87 359 37 Fine dust filter M5 (10 pieces)
T005 87 359 38 Fine dust filter F7 (10 pieces)
10 Disposal
Dispose of replaced equipment parts, filters or old devices in
accordance with the rules and regulations applicable in your country.
11 Warranty
Claims based on defects will fall under the statute of limitations
12 months after delivery to the purchaser of the goods. This shall not
apply to rights of recourse of the purchaser according to sections
478, 479 German Civil Code.
We shall only be liable in the case of a warranty we have issued if
the quality or service life guarantee has been issued by us in writing
with reference to the term "warranty".
Subject to technical alterations and amendments! See the updated
operating instructions at www.weller-tools.com.

EN
FR
IT
ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
WFE 2ES
Mode d'emploi

WFE 2ES
WFE 2ES
Vue d'ensemble de
l'appareil
1 Ouverture d'air d'évacuation
2 Corps de filtres
3 Prise d'aspiration
4 Attaches
5 Interrupteur d'alimentation
6 Fusible
7 Branchement secteur
8 Carter de turbine
9 Bouchon
10 Filtre pour poussières fines
11 Filtre compact
12 Plaque de turbine
10
11
12
8
2

WFE 2ES 3-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Table des matières
1A propos du mode d'emploi ....................................................... 3
2Pour votre sécurité ..................................................................... 4
3Le WFE 2ES comprend : ........................................................... 4
4Description de l'appareil ............................................................ 5
5Mise en service de l'appareil ..................................................... 5
6Aspiration des fumées de soudage ........................................... 6
7Changement des filtres .............................................................. 7
8Messages d'erreur et élimination des défauts ........................... 8
9Accessoires ............................................................................... 8
10 Elimination ................................................................................. 8
11 Garantie ..................................................................................... 8
1A propos du mode d'emploi
Nous vous remercions de la confiance que vous nous avez
accordée en achetenant le système Weller WFE 2ES. Les
exigences de qualité les plus sévères ont été appliquées à sa
fabrication garantissant ainsi son parfait fonctionnement.
Le présent mode d'emploi contient des informations importantes
pour une utilisation conforme et un fonctionnement en toute sécurité
du système d'aspiration WFE 2ES ainsi que des recommandations
d'entretien et de réparation de défauts mineurs.
ZAvant de mettre l'aspirateur WFE 2ES en service, lisez
entièrement le présent mode d'emploi et les consignes de
sécurité qui l'accompagnent.
ZConservez ce mode d'emploi à un endroit accessible à tous les
utilisateurs.
1.1 Directives applicables
L'aspirateur de fumées WFE 2ES de Weller correspond aux
indications données dans la déclaration de conformité aux directives
2004/108/CE et 2006/95/CE.
1.2 Documents citées
−Mode d'emploi de l'aspirateur de fumée WFE 2ES
−Livret sur les consignes de sécurité accompagnant le mode
d'emploi

4-8 WFE 2ES
2Pour votre sécurité
L'aspirateur de fumées WFE 2ES a été conçu et fabriqué
conformément à l'état actuel de la technique et les réglementations
et connaissances les plus récentes en matière d’hygiène et de
sécurité. Malgré ces précautions prises, des risques de dommages
corporels ou matériels subsisteront, si vous ne respectez pas les
consignes du livret de sécurité ainsi que les avertissements du
présent mode d'emploi. Lorsqu'il est cédé à des tiers, l'aspirateur de
fumées WFE 2ES doit toujours être accompagné de son mode
d'emploi.
2.1 Limites d'utilisation
L'aspirateur de fumées WFE 2ES doit exclusivement être utilisé à la
destination indiquée dans le mode d'emploi, à savoir pour
l'aspiration des fumées de soudage au-dessus des plans de travail,
et dans les conditions spécifiées. L'utilisation conforme à la
destination prévue implique également le respect
−des consignes du présent mode d'emploi,
−des consignes de l'ensemble des autres documents qui
l'accompagnent,
−de la réglementation d'hygiène et de sécurité en vigueur dans le
pays d'utilisation.
Le fabricant décline toute responsabilité quant aux modifications
effectuées de façon arbitraire sur l'appareil.
3Le WFE 2ES comprend :
−le système WFE 2ES y compris les filtres
−le câble de raccordement
−mode d'emploi
−le livret des consignes de sécurité
Other manuals for WFE 2ES
1
Table of contents
Languages:
Other Weller Scrubber manuals

Weller
Weller WFE P User manual

Weller
Weller Zero Smog TL User manual

Weller
Weller Zero Smog 4V User manual

Weller
Weller Zero Smog TL User manual

Weller
Weller Zero Smog EL User manual

Weller
Weller Zero-Smog WFE 20D User manual

Weller
Weller MG100S User manual

Weller
Weller MG100S User manual

Weller
Weller Laser Line LL150 User manual

Weller
Weller FT12 User manual
Popular Scrubber manuals by other brands

BETCO
BETCO STEALTH ASC24BT Operator and parts manual

Brain Corp
Brain Corp ICE Robotics RS26 Operational manual

Jefferson
Jefferson JEFLUEXTM07 user manual

Windsor
Windsor Saber Cutter SC326 10052220 operating instructions

Olympus
Olympus M200H operating manual

American-Lincoln
American-Lincoln 505-945 Instructions for use