4
INSTALLATION CONTINUED
BEFORE STARTI G THE ASSEMBLY CO TI UED
4. The room where the Makeup Stations will be installed must be permanently wired with a suitable
electrical source (grounded 120VAC).
a. Each 9-light Station (lighting using 540 watts) or 8-light Station (lighting using 480 watts) can
have external appliances plugged into the duplex receptacle that can draw high current loads.
Make sure that the electrical supply is capable of supplying sufficient current and has adequate
overload protection.
b. Always consult local electrical codes before starting the installation.
Warning: A licensed electrician must do the electrical installation. Failure to observe this
precaution can result in serious injury, death, or damage to property.
Warning: The studio electrical source must must be permanently wired and comply with local
electrical codes. This must include a switch(s) that can disconnect the Studio Makeup
Station outlet(s) and must include a pilot light outside the dressing room door to
indicate that the outlet circuitry is energized. Failure to observe this precaution can
result in serious injury, death, or damage to property.
LAYOUT THE SPACE
ote: Refer to the illustration on the opposite page (page 5) which includes equivalent metric
dimensions.
1. Before starting the installation, decide where the Studio Makeup Stations will be installed.
2. If the wall is drywall or wetwall construction, determine if the studs are wood or steel.
3. Draw a vertical line on the wall that will locate the vertical centerline of the left (or right) Station.
a. Make sure that the line is vertical to the floor.
b. The centerline cannot be closer than 20-1/2-inches (36-inch Model) or 17-1/2-inches (30-inch
Model) from an obstruction on either side (such as a wall, I-beam, cabinet, etc.).
c. If more than one Studio Makeup Station is being installed, measure 30-inches or 36-inches
(depending upon the Model) from the centerline and draw another vertical line for the centerline
of the second Station.
d. Draw additional centerlines for any additional Stations that will be installed.
e. Draw a horizontal line 57-1/2-inches from the floor across the centerlines. Make sure that the
line is level. This line locates the top edge of the Mounting Bracket (36-inch Model is 23-1/2-
inches wide and 30-inch Model is 17-1/2-inches).
ote: Placing the top edge of the Mounting Bracket at 57-1/2-inches from the floor will locate the top
surface of the Counter at 29-inches from the floor and the top of the Shelf at 68-1/2-inches from
the floor. If the Counter top surface must be higher or lower, adjust the Mounting Bracket
Position by moving it upward or downward.
4. Using an electronic scanner, locate and mark each stud in the wall that will be used for the
installation with a vertical line that passes through the horizontal line that locates the top edge of the
Mounting Bracket.
ote: Sometimes the 30-inch Model Mounting Bracket does not cross a wall stud. If the Mounting
Bracket cannot be attached to a wall stud, refer to the special instructions for wall anchors in the
section Install the Mounting Bracket.
LIGHTI G
The Studio Makeup Station is shipped without light bulbs. Wenger Corporation recommends the use of
GE Reveal®40-watt or GE Reveal®60-watt incandescent bulbs or 15 watt full-spectrum swirl
fluorescent bulbs. Ambient lighting conditions may influence the choice of bulb type and power rating.