CAUTION
!
WARNING
!
If you do not follow these instructions exactly, a fire or explosion may
result, causing property damage, personal injury or loss of life.
DO NOT BEGIN INSTALLATION UNTIL YOU READ
THE FOLLOWING PRECAUTIONS.
PRECAUTIONS
1. Turnoffelectricalpowertothesystematthefusebox
or circuit breaker. Also turn off the main gas supply.
2. Ifreplacinganexistingvalve,disconnectallplumbing
and electrical connections from the old control.
3. The control may be installed in any position, except
upsidedown.Thearrowonthebottomplateindicates
the direction of gas flow through the valve.
4. You should use new pipe that is properly chamfered,
reamed, and free of burrs and chips. If you are using
old pipe, be sure it is clean and free of rust, scale,
burrs, chips, and old pipe joint compound.
5. Apply pipe joint compound (pipe dope) or teflon tape
that is approved for all gases, only to the male
threads of the pipe joints. DO NOT apply com-
poundorteflontapetothefirsttwothreads(seefig. 2
for typical piping connections).
1. Failure to turn off electric or main gas supply
toheatingsystemcouldcausepersonalinjury
and/or property damage by shock, gas suffo-
cation, fire, and/or explosion.
2. Do not use this control on circuits exceeding
specified voltage. Higher voltage will damage
the control and may cause shock or fire
hazard.
3. NEVERUSEFLAME OR ANY KIND OF SPARK
TO CHECK FOR GAS LEAKS–COULD CAUSE
FIRE AND/OR EXPLOSION.
4. DONOTUSEWIREJUMPERonpilotsystems,
such as standing pilot, proven pilot, or spark-
to-pilot ignition–a fire and/or explosion may
result.
5. DonotuseacontrolsetfornaturalgaswithLP
gas, or a control set for LP gas with natural
gas. Personal injury and/or property damage,
gas suffocation, fire, and/or explosion may
result.
1. Do not short out terminals on gas valve or
primary control to test. Short or incorrect
wiring can cause equipment damage, prop-
erty damage, and/or personal injury.
2. This control is not intended for use in loca-
tionswhere itmay come in direct contact with
water.Suitableprotectionmustbeprovidedto
shield the control from exposure to water
(dripping, spraying, rain, etc.).
INSTALLATION
6. Ifyouareusingaviseoropen-endwrenchtoholdthe
valve while installing piping, do not tighten exces-
sively, as this may damage the valve.
7. See SYSTEM WIRING when making electrical con-
nections. After all gas and electrical connections are
completed, turn gas on and check for gas leaks with
leakdetectionsolutionorsoapsuds.Bubblesforming
indicate a leak. SHUT OFF GAS AND FIX ALL
LEAKS IMMEDIATELY.