manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. WHITECROFT LIGHTING
  6. •
  7. Lantern
  8. •
  9. WHITECROFT LIGHTING ACL INDUSTRY Manual

WHITECROFT LIGHTING ACL INDUSTRY Manual

Whitecroft Lighting Limited
Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone +44 (0)870 5 087 087 Facsimile: +44 (0)870 5 084 210
Registered No. 3848973 England Registered Office: As above
PK/LEAFLETACLLED
TECHNICAL SUPPORT Tel: 0161 331 5700
e-mail: technical@whitecroftlight.com
ACL INDUSTRY
Installation Leaflet
Feb 2019 - Rev G
SPECIFICATION
FURTHER INFORMATION
In common with all IP66 rated fittings the ACL
Industry luminaire is protected against ingress of
dust and water projected from a nozzle. However
care must be taken in the siting of these
luminaires. They can be mounted outdoors under
a canopy or covered environment but should not
be in direct sunlight or open areas exposed to
adverse weather conditions. In particular they
should not be installed in an environment liable to
produce standing water on the fitting or IP glands.
Lamp type: LED 4000°K
Control Gear: Fixed Output / DALI
Body Material: Light Grey PC
Diffuser
material:
Opal High Impact PC with
internal prisms
Supply: 220-240V AC, 50Hz
Operating
temp:
Standard -20°C to 25°C
Emergency -5°C to 25°C
Conductor: 2.5mm2 max
Rating: IP66 / IK08
Weight:
1283mm
1578mm
Std 2.75 kg Em. 3.25 kg
Std 3.4 kg Em. 3.9 kg
GENERAL INFORMATION
1. A qualified electrician, in
accordance with IEE wiring
regulations, should carry out
connection to mains wiring.
2. Ensure mains power is
turned off during
maintenance.
3. Ensure that the rated voltage
and frequency requirements
are compatible with the
available mains supply.
4. This unit must be
EARTHED.
5. Cleaning of reflectors and
lenses should be carried out
using clean, soft and lint free
cloths and anti-static
cleaning fluid.
6. Do not carry out high voltage
insulation test, i.e.
500/1000v this may damage
internal components.
7. Replacing the light source
within this luminaire shall
only be carried out by the
manufacturer,
service agent or a
similar qualified
person.
PLEASE NOTE: In
freezer applications
product must be
mounted a minimum
of 1M from any
ventilation including
the freezer door.
All measurements in
mm unless stated
otherwise, see website
for product codes and
lumen outputs
Variant Length Cable Entry
Points
Mount Bracket
Centres
Surface Mount
Centres
0.6m 663 530 390 266
1.2m 1283 1050/1170 800 676
1.5m 1578 1345/1170 1100 976
LED INSTALLATION SEQUENCE
1. Remove the luminaire from the
packaging, lift the diffuser and
set it to one side.
2. Remove the gear tray from the housing
by squeezing the plastic clips together
at both ends. (Fig.1)
HIGH VOLTAGE LEDs
ELECTROSTATIC SENSITIVE DEVICE
3. Remove the plastic bag containing the
ceiling fixing kit, diffuser retention clips,
sealing grommets.
4. There are 2 mounting options with the
supplied components - surface
mounted or suspended (Fig. 2).
Fig. 1
5. For secure
suspension
i.e. in an area
with a high
risk of lateral
movement use
the
ACFHOOKKIT
(supplied
separately -
additional
rubber washer
required for IP
seal not
included).
6. For direct
surface
mounting use
suitable
screws and
washers
(supplied by others) through the same mounting bosses as the hook kit. Ensure
that washers are correctly fitted to the inside of the bosses to maintain the IP
rating.
Page 1
DETECTION AREA
Detection area can be reduced
by selecting the combination
on the DIP switches to fit
precisely for each specific
application.
HOLD TIME
Hold-time means the time
period you would like to keep
the lamp on 100% after the
person has left the detection
area.
DAYLIGHT SENSOR - NOT USED
DEFAULT SETTING I - DISABLED
STAND-BY PERIOD
(CORRIDOR FUNCTION)
This is the time period you
would like to keep at the low
light output level before it is
completely switched off in the
long absence of people.
Note: “0s” means on/off
control; “+ ∞” means bi-level
dimming control, fixture never
switches off.
STAND-BY DIMMING
LEVEL
This is the dimmed low light
output level you would like to
have after the hold-time in the
absence of people.
Page 6
Fig. 2
DALI
MAINS
DALI EM /
COMEPS
7. Bring the incoming supply wires into the luminaire body through the knock-outs at
the end of the body or on the rear (Fig.3) using the supplied sealing grommets.
Seal any unused cable entry holes with the closed grommets supplied.
8. Lift the gear tray back
into position and hook
onto the plastic
retention clips within
the housing. (Fig.4)
9. Make all electrical
connections to the
terminal blocks (Fig.4)
and connect the
emergency batteries if
applicable.
10. Clip the gear tray back into the housing. (Fig.5)
11. Set sensor dip switch configuration if
applicable. (see pages 3-6)
12. Remove the two anti tamper screws from the gear tray for fixing diffuser clips.
(Fig. 6)
13. Fit the diffuser back into position using all of the retention clips and secure two
plastic clips on opposite sides with the anti-tamper screws provided. (Fig.6)
Fig. 5
CLICK!
Fig. 4
Fig. 6
Page 2Page 5
COMMAND 5 SENSOR WITH SETBACK
DIP SWITCH CONFIGURATION
Model: HCD418
The sensor is a motion
switch. It turns the light ON
after detection of moving
objects and turns the light
OFF after a pre-selected
hold-time when there is no
motion detected.
DETECTION AREA PATTERN
INSTALLATION OF LUMINAIRE
Note: Important to consider
 The sensor provides DALI output to the driver to perform on / off / setback
control only. The sensor must not be connected to a DALI network.
 The sensor can detect movements though thin walls and glass; detection
range (sensitivity) should be adjusted in accordance with site conditions.
 Luminaire must be fixed to a solid surface to avoid false-triggering caused by
vibration.
 Large metal surfaces can cause unwanted detection.
 Ventilation shafts and airflow can cause unwanted detection.
 Luminaires mounted within each other’s detection range may need their
sensitivity reduced to avoid possible nuisance switching.
Page 3
DETECTION AREA
Detection area can be
reduced by selecting
the combination on the
DIP switches to fit
precisely for each
specific application.
HOLD TIME
Hold-time means the
time period you would
like to keep the lamp on
100% after the person
has left the detection
area.
DAYLIGHT SENSOR -
NOT USED
DEFAULT SETTING I -
DISABLED
Page 4
COMMAND 5 ECO SENSOR
DIP SWITCH CONFIGURATION
Model: HC005s
The sensor is a motion
switch. It turns the light ON
after detection of moving
objects and turns the light
OFF after a pre-selected
hold-time when there is no
motion detected.
DETECTION AREA PATTERN
INSTALLATION OF LUMINAIRE
Note: Important to consider
 The sensor can detect movements though thin walls and glass; detection
range (sensitivity) should be adjusted in accordance with site conditions.
 Luminaire must be fixed to a solid surface to avoid false-triggering caused by
vibration.
 Large metal surfaces can cause unwanted detection.
 Ventilation shafts and airflow can cause unwanted detection.
 Luminaires mounted within each other’s detection range may need their
sensitivity reduced to avoid possible nuisance switching.

Other WHITECROFT LIGHTING Lantern manuals

WHITECROFT LIGHTING TEGAN SLIM 600SQ User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING TEGAN SLIM 600SQ User manual

WHITECROFT LIGHTING Florin IP65 User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Florin IP65 User manual

WHITECROFT LIGHTING Avenue Metro Suspended User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Avenue Metro Suspended User manual

WHITECROFT LIGHTING Aerial Industry User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Aerial Industry User manual

WHITECROFT LIGHTING Cygnus SY User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Cygnus SY User manual

WHITECROFT LIGHTING Aerial Industry User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Aerial Industry User manual

WHITECROFT LIGHTING Florin E3 Series Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Florin E3 Series Manual

WHITECROFT LIGHTING Foil SRD Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Foil SRD Manual

WHITECROFT LIGHTING Cygnus SX Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Cygnus SX Manual

WHITECROFT LIGHTING Aerial Industry User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Aerial Industry User manual

Popular Lantern manuals by other brands

RH HAYES quick start guide

RH

RH HAYES quick start guide

SIGNIFY LUMEC ULM100 instructions

SIGNIFY

SIGNIFY LUMEC ULM100 instructions

Kemper SOLEADO ARKO Instructions for use

Kemper

Kemper SOLEADO ARKO Instructions for use

McLED LINE user manual

McLED

McLED LINE user manual

esotec Sunnylight Usage instructions

esotec

esotec Sunnylight Usage instructions

Philips series Installation and operating instructions

Philips

Philips series Installation and operating instructions

olympia electronics CLASSIC LIGHT Series quick start guide

olympia electronics

olympia electronics CLASSIC LIGHT Series quick start guide

Home Decorators Collection HB7064-306 Use and care guide

Home Decorators Collection

Home Decorators Collection HB7064-306 Use and care guide

Coleman 4D CPX 6 LED DOUBLE EDGE user guide

Coleman

Coleman 4D CPX 6 LED DOUBLE EDGE user guide

PL&T Shoplight With Sensor installation instructions

PL&T

PL&T Shoplight With Sensor installation instructions

Nitecore LR40 user manual

Nitecore

Nitecore LR40 user manual

Emerson Appleton Areamaster instruction sheet

Emerson

Emerson Appleton Areamaster instruction sheet

BEGA 77 814 Instructions for use

BEGA

BEGA 77 814 Instructions for use

Allen + Roth WL133MBK manual

Allen + Roth

Allen + Roth WL133MBK manual

Wetelux 87 46 32 instruction manual

Wetelux

Wetelux 87 46 32 instruction manual

IKEA STRALA J2024 manual

IKEA

IKEA STRALA J2024 manual

Gama Sonic GS-106P instruction manual

Gama Sonic

Gama Sonic GS-106P instruction manual

Stahl TRANHBERG TEF 2440 user manual

Stahl

Stahl TRANHBERG TEF 2440 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.