WIKA 55 Series Operating instructions

DE
EN
Additional operating instructions
Zusatz-Betriebsanleitung
Mode d’emploi complémentaires
Manual de instrucciones adicional
ES
FR
Model R5502
Additional operating instructions for hazardous areas
Model 55 + option ATEX
Zusatz-Betriebsanleitung für explosionsgefährdete
Bereiche, Typ 55 + option ATEX
Mode d’emploi complémentaires concernant les zones
explosives, type 55 + option ATEX
Manual de instrucciones adicional para zonas
potencialmente explosivas, modelo 55 + option ATEX
CE Ex
II 2G Ex h IIC T6 ...T1 Gb X
II 2D Ex h IIIC T85 °C ...T450 °C Db X

DE
EN
ES
FR
2
© 12/2010 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
Additional operating instructions model 55
(ATEX)
Page 3 - 14
Zusatz-Betriebsanleitung Typ 55 (ATEX)
Seite 15 - 26
Mode d‘emploi complémentaires
type 55 (ATEX)
Page 27 - 38
Manual de instrucciones adicional
modelo 55 (ATEX)
Página 39 - 50
11583747.07 12/2021 EN/DE/FR/ES
WIKA additional operating instructions model 55 (ATEX)

EN
Supplementary documentation:
▶This additional operating instructions for hazardous areas
applies in conjunction with the operating instructions “Bimetal
thermometer, model 55” (article number 12968065).
11583747.07 12/2021 EN/DE/FR/ES
4WIKA additional operating instructions model 55 (ATEX)
1. Safety
DANGER!
Danger to life due to loss of explosion protection
Non-observance of these instructions and their contents
may result in the loss of explosion protection.
▶Observe the safety instructions in this chapter and
further explosion instructions in these operating
instructions.
▶Follow the requirements of the ATEX directive.
▶Observe the information given in the applicable
type examination certicate and the relevant
regulations for installation and use in hazardous areas
(e.g. IEC 60079-11, IEC 60079-10 and IEC 60079-14).
1.1 Explanation of symbols
DANGER!
... indicates a potentially dangerous situation in the
hazardous area that can result in serious injury or death, if
not avoided.
1. Safety

EN
11583747.07 12/2021 EN/DE/FR/ES
WIKA additional operating instructions model 55 (ATEX) 5
1.2 Intended use
These bimetal thermometers are used for measuring temperature in
hazardous areas of industrial applications.
The instrument has been designed and built solely for the intended
use described here, and may only be used accordingly.
Check whether the classication is suitable for the application (see Ex
marking, chapter 1.5 “Labelling, safety marks”). Observe the relevant
national regulations.
The non-observance of the instructions for use in hazardous areas
can lead to the loss of the explosion protection. Adhere to the
following limit values and instructions (see data sheet).
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
1.3 Responsibility of the operator
The responsibility for classication of zones lies with the plant
operator and not the manufacturer/supplier of the equipment.
1.4 Personnel qualication
The skilled personnel must have knowledge of ignition protection
types, regulations and provisions for equipment in hazardous areas.
1. Safety

EN
11583747.07 12/2021 EN/DE/FR/ES
6WIKA additional operating instructions model 55 (ATEX)
1.5 Labelling, safety marks
Product label (example)
Model + option ATEX
Ex marking
Year of manufacture
Serial number
Before mounting and commissioning the instrument,
ensure you read the operating instructions!
Do not ll the instruments with lling liquid subsequently.
"MODEL"
35
15
R1
With variables:
Mit Variablen:
Without variables:
Ohne Variablen:
Serial number acc. to Order
Seriennummer nach Auftrag
Year of production
Produktionsjahr
"Model" NS / NG A# RI / ÄI
A5525 63 14481642 01
A5500 100 14481643 01
A5501 160 14481644 01
R5526 63 14481645 01
R5502 100 14481646 01
R5503 160 14481647 01
S55xx 63 not available -
S5550 100 14481648 01
S5551 160 14481649 01
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85°C ... T450°C Db X
Thermometer + option ATEX
Example:
Beispiel:
Model acc. to Order
Modell nach Auftrag
WIKA 63911 Klingenberg / Germany
"SERIAL-NO" "YEAR"Year
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85°C ... T450°C Db X
Thermometer + option ATEX
WIKA 63911 Klingenberg / Germany
A5500
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85°C ... T450°C Db X
Thermometer + option ATEX
WIKA 63911 Klingenberg / Germany
5
Serial No.:
Year
Serial No.:
Year
Serial No.: ABCD123456 2021
www.wika.com
D-63911 Klingenberg
ALEXANDER WIEGAND SE & Co. KG
Printed versions are not subject to change management and are not subject to update service and are not considered valid.
All rights as well as rights to register patents and other property rights reserved. Any reproduction or disclosure only with authorization from WIKA.
Ausgedruckte Versionen unterliegen nicht dem Änderungsdienst und haben keinen Anspruch auf Aktualität.
Alle Rechte sowie Rechte zur Anmeldung von Patenten und anderen Schutzrechten vorbehalten. Vervielfältigung und Weitergabe nur mit Genehmigung durch WIKA.
by WIKA
1 2
A
B
C
D
E
3 4
F
DEKLI1_EN_A4M_T01 15.04.2020
ISO 8015
SIZE ISO 14405
mm
units
Check indicator
[inch]
language
GER/ENG
sheets /
reference
modified
released
size
nominal
material
raw
part
scale
.
UV/DR
comments
drawing number
GG
µm
z
R in ±0.5±0.3±0.2
...400...120...30 >120>30>6
±0.1
...6
0.5
Tol. ISO 2768 - mK
141663-
ISO 1302 xyz
Surface texture
first created
01
REVISION
Workflow
Prüfung-01
15.02.21
15.02.2021
HOHMST
14475129
SCHILD
16
01
2:1 11
07.05.21 HOHMST
14113998
Rollhaftetikette PET sillber matt
Roll adhesive PET silver dull
SORT-ZCHG SHI 35*15 THERMOMETER TYP 55 ATEX (EX c) O.EZE ETK SKL
LABEL
Only for information / Nur zur Information
1. Safety

EN
11583747.07 12/2021 EN/DE/FR/ES
WIKA additional operating instructions model 55 (ATEX) 7
Ex marking
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85 °C ... T450 °C Db X
Marking Designation Meaning
CE marking European conformity
Specic marking for
explosion protection
Ex symbol
II Symbol of the
equipment group
Equipment intended for use in other
places than underground parts of mines,
and in those parts of surface installations
of such mines, liable to be endangered by
redamp and/or combustible dust and an
explosive atmosphere.
2Symbol of the
equipment category
High safety, approved for zone 1 and 21
GEx atmosphere Concerning explosive atmospheres
caused by gases, vapours or mists
DEx atmosphere Concerning explosive atmospheres
caused by dust
Ex Ex marking Standards ISO 80079-36 and
ISO 80079-37 applied
hIgnition protection
type
Non-electrical equipment for explosive
atmospheres
An ignition protection type is not applied
to the letter “h”.
IIC Suitable atmosphere Gas atmosphere group IIC
IIIC Suitable atmosphere Combustible yings, non-conductive dust
and conductive dust
T6 ... T1 Maximum surface
temperature
Symbol indicating the temperature class
The actual maximum surface temperature
depends not on the equipment itself, but
mainly on the operating conditions.
1. Safety

EN
11583747.07 12/2021 EN/DE/FR/ES
8WIKA additional operating instructions model 55 (ATEX)
Marking Designation Meaning
T85 °C ...
T450 °C
Maximum surface
temperature
Maximum surface temperature
The actual maximum surface temperature
depends not on the equipment itself, but
mainly on the operating conditions.
Gb Equipment Protection
Level (EPL)
Potential ignition sources that are eective
or may become eective during normal
operation and expected malfunction
Db
XSpecic conditions
of use see operating
instructions
Ambient temperature with special range
Specic conditions of use apply.
2. Commissioning, operation
DANGER!
Danger to life from missing instrument grounding
With missing or incorrect grounding, there exists a risk of
dangerous voltages (leading to, for example, mechanical
damage, electrostatic charge or induction).
▶Ground thermometer!
Observe the special conditions (see chapter 3 “Special conditions for
use (X conditions)”, point 4).
1. Safety / 2. Commissioning, operation

EN
11583747.07 12/2021 EN/DE/FR/ES
WIKA additional operating instructions model 55 (ATEX) 9
3. Special conditions for use (X conditions)
3. Special conditions for use (X conditions)
1) Design temperatures
Permissible ambient temperature at case:
Temperature ranges
Unlled instrument -40 ...+70 °C
Filled instrument -40 ... +70 °C
Option: low temperature -50 ... +70 °C
Option: POLARgauge®-70 ... +60 °C
Permissible medium temperature: max. end of scale
Observe the surface temperature for ATEX application:
The permissible medium temperature does not only depend on
the instrument design, but also on the ignition temperature of the
surrounding gases, vapours or dust.Take both aspects into account.
2) Maximum surface temperature
The surface temperature mainly depends on the medium and
ambient temperature. The instrument itself does not contain any
heating sources. For prevention, consider the maximum medium
temperature as maximum surface temperature, if it is not possible
to determine the real surface temperature even in the case of
expected malfunctions.
Instruments for use in hazardous gas/air, vapour/air and mist/air
atmospheres:
Temperature class
(gas application)
Maximum permissible surface
temperature (for the end application)
T6 80 °C
T5 95 °C
T4 130 °C
T3 195 °C
T2 250 °C (290 °C) 1)
T1 250 °C (440 °C) 1)
1) only for instruments without liquid lling

EN
11583747.07 12/2021 EN/DE/FR/ES
10 WIKA additional operating instructions model 55 (ATEX)
Hazardous dust atmosphere
For dusts, the procedure specied in ISO/IEC 80079-20-2 for
determining the ignition temperature has to be applied.The
ignition temperature is determined separately for dust clouds and
dust layers, respectively. For dust layers, the ignition temperature
depends on the dust layer thickness per EN/IEC 60079-14.
Ignition temperature
of dust
Maximum permissible medium
temperature (in the measuring system)
Dust cloud T
cloud < 2/3 Tcloud
Dust layer Tlayer < Tlayer − 75 K − (reduction depending on the
layer thickness)
The permissible maximum medium temperature must not exceed
the lowest determined value, even in case of a malfunction.
Explosive atmosphere consisting of hybrid mixtures
The instruments must not be used in areas in which an
atmosphere consisting of explosive hybrid mixtures (dusts mixed
with gases) can occur.
3) Mount the instrument in such a way that, taking into consideration
the inuence of convection and heat radiation, no deviation above or
below the permissible ambient and medium temperatures can occur.
4) The instruments must be earthed via the process connection.
This is why electrically conductive sealing should be used at
the process connection. Alternatively, take other measures for
grounding. External sources of stray electric currents depend on
end use application and must be assessed by the end user.
5) Avoid handling of materials that react dangerously with the
materials used for the instrument, and substances liable to
spontaneous combustion.
3. Special conditions for use (X conditions)

EN
11583747.07 12/2021 EN/DE/FR/ES
WIKA additional operating instructions model 55 (ATEX) 11
3. Special conditions for use (X conditions)
6) Avoidance of vibration
Requirements for the installation point
If the line to the instrument is not adequately stable, an
instrument holder should be used for fastening. If vibrations
cannot be avoided by means of suitable installation, use
instruments with liquid lling. Protect the instruments against
coarse dirt and wide uctuations in ambient temperature.
Permissible vibration load at the installation site
Always install the instruments in locations free from vibration.
If necessary, it is possible to isolate the instrument from the
mounting point, e.g. by installing a exible connection line
between the measuring point and the instrument and mounting
the instrument on a suitable bracket. If this is not possible, do not
exceed the following limits:
Frequency range < 150 Hz
Acceleration < 0.5 g
7) When using thermowells, they must be lled with a thermal
contact medium in order to reduce the heat transfer resistance
between the outer wall of the probe and the inner wall of the
thermowell.The working temperature of the thermal compound is
-40 ... +200 °C.
8) Clean the thermometer with a moist cloth. Ensure that due to the
cleaning no electrostatic charge will be generated.
9) All accessories (e.g. thermowells or attachment components)
must be assessed in combination with the delivered instruments
by the end user. Particularly the requirements of grounding and
prevention of electrostatic charges must be considered.

EN
11583747.07 12/2021 EN/DE/FR/ES
12 WIKA additional operating instructions model 55 (ATEX)
10) Ignition hazard analysis
Relevant identied
ignition hazards
Implemented protective measures
Hot surfaces
■
Actual surface temperature depends on
application; media temperature only
■
Temperature range marking;T range marking
■
Observation of legibility of marking
▶Information given in operation instructions
Mechanically
generated sparks and
hot surfaces
■
Low contact speed
■
Limitation of vibration
■
Selection of suitable materials
▶Information given in operation instructions
Stray electric currents,
cathodic corrosion
protection
■
Grounding via process connection required
▶Information given in operation instructions
Static electricity
■
No propagating brush discharge
■
All conductive parts bonded
■
Limitation of projected area of non-conductive
parts
■
Limitation of layer thickness of
non-conductive parts
■
Grounding via process connection required
■
Description of cleaning process
▶Information given in operation instructions
Exothermic reactions,
including self-ignition
of dusts
■
Provision of material data of the wetted parts
for the customer in order to avoid the use of
critical media
▶Information given in operation instructions
11) The legibility of the marking must be observed during time in use
but at least during inspection periods of three years. If any harm
of the legibility is found please contact the manufacturer to renew
the marking.
12) Due to potential ignition hazards (e.g. static discharge), the
packaging material and the desiccant bag must not be put in the
hazardous area.
13) Permissible operating pressure at the stem: max. 25 bar [360 psi],
static
3. Special conditions for use (X conditions)

EN
11583747.07 12/2021 EN/DE/FR/ES
WIKA additional operating instructions model 55 (ATEX) 13
Appendix: EU declaration of conformity

EN
11583747.07 12/2021 EN/DE/FR/ES
14 WIKA additional operating instructions model 55 (ATEX)

DE
11583747.07 12/2021 EN/DE/FR/ES
16 WIKA-Zusatz-Betriebsanleitung Typ 55 (ATEX)
1. Sicherheit
GEFAHR!
Lebensgefahr durch Verlust des Explosionsschutzes
Die Nichtbeachtung dieser Inhalte und Anweisungen kann
zum Verlust des Explosionsschutzes führen.
▶Sicherheitshinweise in diesem Kapitel sowie weitere
Explosionshinweise in dieser Betriebsanleitung beach-
ten.
▶Die Anforderungen der ATEX-Richtlinie beachten.
▶Die Angaben der geltenden Baumusterprüfbescheini-
gung sowie die jeweiligen Vorschriften zur Installation
und Einsatz in explosionsgefährdeten Bereichen
(z. B. IEC 60079-11, IEC 60079-10 und IEC 60079-14)
einhalten.
1.1 Symbolerklärung
GEFAHR!
... weist auf eine möglicherweise gefährliche Situation
im explosionsgefährdeten Bereich hin, die zum Tod oder
zu schweren Verletzungen führen kann, wenn sie nicht
gemieden wird.
1. Sicherheit
Ergänzende Dokumentation:
▶Diese Zusatz-Betriebsanleitung für explosionsgefährdete
Bereiche gilt im Zusammenhang mit der Betriebsanleitung
„Bimetallthermometer, Typ 55“ (Artikelnummer 12968065).

DE
WIKA-Zusatz-Betriebsanleitung Typ 55 (ATEX)
11583747.07 12/2021 EN/DE/FR/ES
17
1.2 Bestimmungsgemäße Verwendung
Diese Bimetallthermometer dienen zum Messen von Temperatur bei
industriellen Anwendungen in explosionsgefährdeten Bereichen.
Das Gerät ist ausschließlich für den hier beschriebenen bestim-
mungsgemäßen Verwendungszweck konzipiert und konstruiert und
darf nur dementsprechend verwendet werden.
Überprüfen, ob die Klassizierung für den Einsatzfall geeignet ist
(siehe Ex-Kennzeichnung, Kapitel 1.5 „Beschilderung, Sicherheits-
kennzeichnungen“). Die jeweiligen nationalen Vorschriften und
Bestimmungen beachten.
Das Nichtbeachten der Angaben für den Einsatz in explosionsgefähr-
deten Bereichen führt zum Verlust des Explosionsschutzes. Grenz-
werte und technische Angaben einhalten (siehe Datenblatt).
Ansprüche jeglicher Art aufgrund von nicht bestimmungsgemäßer
Verwendung sind ausgeschlossen.
1.3 Verantwortung des Betreibers
Die Verantwortung über die Zoneneinteilung unterliegt dem Anlagen-
betreiber und nicht dem Hersteller/Lieferanten der Betriebsmittel.
1.4 Personalqualikation
Das Fachpersonal muss Kenntnisse haben über Zündschutzarten,
Vorschriften und Verordnungen für Betriebsmittel in explosionsgefähr-
deten Bereichen.
1. Sicherheit

DE
11583747.07 12/2021 EN/DE/FR/ES
18 WIKA-Zusatz-Betriebsanleitung Typ 55 (ATEX)
1.5 Beschilderung, Sicherheitskennzeichnungen
Typenschild (Beispiel)
Typ + Option ATEX
Ex-Kennzeichnung
Herstellungsjahr
Seriennummer
Vor Montage und Inbetriebnahme des Gerätes
unbedingt die Betriebsanleitung lesen!
Geräte nicht nachträglich mit Füllüssigkeit befüllen.
"MODEL"
35
15
R1
With variables:
Mit Variablen:
Without variables:
Ohne Variablen:
Serial number acc. to Order
Seriennummer nach Auftrag
Year of production
Produktionsjahr
"Model" NS / NG A# RI / ÄI
A5525 63 14481642 01
A5500 100 14481643 01
A5501 160 14481644 01
R5526 63 14481645 01
R5502 100 14481646 01
R5503 160 14481647 01
S55xx 63 not available -
S5550 100 14481648 01
S5551 160 14481649 01
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85°C ... T450°C Db X
Thermometer + option ATEX
Example:
Beispiel:
Model acc. to Order
Modell nach Auftrag
WIKA 63911 Klingenberg / Germany
"SERIAL-NO" "YEAR"Year
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85°C ... T450°C Db X
Thermometer + option ATEX
WIKA 63911 Klingenberg / Germany
A5500
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85°C ... T450°C Db X
Thermometer + option ATEX
WIKA 63911 Klingenberg / Germany
5
Serial No.:
Year
Serial No.:
Year
Serial No.: ABCD123456 2021
www.wika.com
D-63911 Klingenberg
ALEXANDER WIEGAND SE & Co. KG
Printed versions are not subject to change management and are not subject to update service and are not considered valid.
All rights as well as rights to register patents and other property rights reserved. Any reproduction or disclosure only with authorization from WIKA.
Ausgedruckte Versionen unterliegen nicht dem Änderungsdienst und haben keinen Anspruch auf Aktualität.
Alle Rechte sowie Rechte zur Anmeldung von Patenten und anderen Schutzrechten vorbehalten. Vervielfältigung und Weitergabe nur mit Genehmigung durch WIKA.
by WIKA
1 2
A
B
C
D
E
3 4
F
DEKLI1_EN_A4M_T01 15.04.2020
ISO 8015
SIZE ISO 14405
mm
units
Check indicator
[inch]
language
GER/ENG
sheets /
reference
modified
released
size
nominal
material
raw
part
scale
.
UV/DR
comments
drawing number
GG
µm
z
R in ±0.5±0.3±0.2
...400...120...30 >120>30>6
±0.1
...6
0.5
Tol. ISO 2768 - mK
141663-
ISO 1302 xyz
Surface texture
first created
01
REVISION
Workflow
Prüfung-01
15.02.21
15.02.2021
HOHMST
14475129
SCHILD
16
01
2:1 11
07.05.21 HOHMST
14113998
Rollhaftetikette PET sillber matt
Roll adhesive PET silver dull
SORT-ZCHG SHI 35*15 THERMOMETER TYP 55 ATEX (EX c) O.EZE ETK SKL
LABEL
Only for information / Nur zur Information
1. Sicherheit

DE
WIKA-Zusatz-Betriebsanleitung Typ 55 (ATEX)
11583747.07 12/2021 EN/DE/FR/ES
19
Ex-Kennzeichnung
II 2G Ex h IIC T6 ... T1 Gb X
II 2D Ex h IIIC T85 °C ... T450 °C Db X
Zeichen Bezeichnung Bedeutung
CE-Zeichen Europäische Konformität
Spezische
Kennzeichnung für
Explosionsschutz
Ex-Symbol
II Symbol der
Gerätegruppe
Geräte, die zur Verwendung in anderen
Bereichen bestimmt sind, als Untertage-
betrieben von Bergwerken sowie deren
Übertageanlagen, die durch Grubengas und/
oder brennbare Stäube gefährdet werden
können und die durch eine explosionsfähige
Atmosphäre gefährdet werden können.
2Symbol der
Gerätekategorie
Hohe Sicherheit, geeignet für Zone 1 und 21
GEx-Atmosphäre Für Bereiche, in denen explosionsfähige
Gas-, Dampf-, Nebel- oder Luftgemische
vorhanden sind
DEx-Atmosphäre Für Bereiche, in denen Staub
explosionsfähige Atmosphären bilden kann
Ex Ex-Kennzeichnung Normen ISO 80079-36 und ISO 80079-37
angewendet
hZündschutzart Nicht-elektrische Geräte für den Einsatz in
explosionsfähigen Atmosphären
Eine Zündschutzart wird für den Buchstaben
„h“ nicht angewendet.
IIC Geeignete
Atmosphäre
Gas-Atmosphäre Gruppe IIC
IIIC Geeignete
Atmosphäre
Brennbare Schwebstoe, nicht-leitfähiger
Staub und leitfähiger Staub
1. Sicherheit

DE
11583747.07 12/2021 EN/DE/FR/ES
20 WIKA-Zusatz-Betriebsanleitung Typ 55 (ATEX)
Zeichen Bezeichnung Bedeutung
T6 ... T1 Maximale
Oberächen-
temperatur
Symbol, das die Temperaturklasse angibt
Die tatsächliche maximale Oberächen-
temperatur hängt nicht vom Gerät selbst ab,
sondern hauptsächlich von den Betriebs-
bedingungen.
T85 °C ...
T450 °C
Maximale
Oberächen-
temperatur
Maximale Oberächentemperatur
Die tatsächliche maximale Oberächen-
temperatur hängt nicht vom Gerät selbst ab,
sondern hauptsächlich von den Betriebs-
bedingungen.
Gb Geräteschutz-
niveau (EPL)
Potenzielle Zündquellen, die im Normal-
betrieb und bei zu erwartenden Störungen
wirksam sind oder wirksam werden können
Db
XBesondere
Anwendungsbe-
dingungen siehe
Betriebsanleitung
Umgebungstemperatur mit speziellem
Bereich
Es gelten besondere Einsatzbedingungen.
2. Inbetriebnahme, Betrieb
GEFAHR!
Lebensgefahr bei fehlender Geräteerdung
Bei fehlender oder falscher Geräteerdung besteht die
Gefahr von gefährlicher Spannung (hervorgerufen durch z.
B. mechanische Beschädigung, elektrostatische Auadung
oder Induktion).
▶Thermometer erden!
Besondere Bedingungen beachten (siehe Kapitel 3 „Besondere
Bedingungen für die Verwendung (X-Conditions)“, Punkt 4).
1. Sicherheit / 2. Inbetriebnahme, Betrieb