Wilfa HU-400BCA User manual

EN ·Instruction manual NL ·Instructies
NO ·Bruksanvisning PL ·Instrukcje
SE ·Bruksanvisning FR ·Instructions
DK ·Betjeningsvejledning IT ·Manuale di istruzioni
FI ·Käyttöohje ES ·Manual de instrucciones
DE ·Anleitung
HAZE
HUMIDIFIER HU-400BCA


NO
SE
DK
FI
EN
NL
PL
FR
IT
ES
DE
LES ALLE ANVISNINGER FØR BRUK
LÄS IGENOM ALLA INSTRUKTIONER INNAN PRODUKTEN ANVÄNDS
LÆS ALLE VEJLEDNINGER INDEN BRUG
LUE OHJEET HUOLELLISESTI ENNEN KÄYTTÖÄ
READ ALL INSTRUCTIONS BEFORE USE
LEES VÓÓR GEBRUIK ALLE INSTRUCTIES
PRZED UŻYCIEM ZAPOZNAĆ SIĘ ZE WSZYSTKIMI ZALECENIAMI
PRENEZ CONNAISSANCE DE TOUTES LES INSTRUCTIONS AVANT UTILISATION
LEGGERE TUTTE LE ISTRUZIONI PRIMA DELL’USO
LEA TODAS LAS INSTRUCCIONES ANTES DE USAR
LESEN SIE DIE ANLEITUNG VOR DEM GEBRAUCH GRÜNDLICH DURCH

EN
2
INSTRUCTION MANUAL · HUMIDIFIER

EN
3
HAZE ·HU-400BCA
CONTENTS
4 IMPORTANT SAFETY INSTRUCTIONS
8 PRODUCT OVERVIEW
9 BEFORE USE
10 USE
12 TROUBLESHOOTING
16 MAINTENANCE
18 GUARANTEE
19 PRODUCT SPECIFICATIONS
19 SUPPORT AND SPARE PARTS
19 RECYCLABILITY

EN
4
INSTRUCTION MANUAL · HUMIDIFIER
IMPORTANT SAFETY INSTRUCTIONS
• Please follow all the safety precautions listed below
for safety and to reduce the risk of injury or electrical
shock.
• This humidier can be used by children aged
from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
humidier in a safe way and understand the hazards
involved. Children shall not play with the humidier.
Cleaning and user maintenance shall not be made
by children without supervision.
• Before using this humidier ensures that the
voltage of your electricity supply is the same as that
indicated on the rating plate of the humidier.
• Always place the humidier on a hard, at and
level surface. Avoid exposure to direct sunlight and
always keep it away from walls and heat sources such
as stoves, radiators, etc. Warning: The humidier
may not work correctly if it is not placed on a level
surface.
• Do not insert or remove the electric plug on the
humidier with wet hands.
• If the mains cable is damaged it must be replaced
by the manufacturer, its service agent, or similarly
qualied person in order to avoid a hazard.

EN
5
HAZE ·HU-400BCA
• To reduce the risk of electric shock, do not remove
screws. The humidier does not contain any user-
serviceable parts. Please leave all maintenance
work to qualied personnel.
• Fill the tank with fresh, distilled or demineralized
water. Do not drop any other liquid into water tank
or water basin. Do not run the humidier when
there is no water in the tank or the water basin.
• Do not shake the humidier as this might cause
the water spill over into the base of humidier.
• Never touch the water or components while the
humidier is in operation.
• If there is an unusual smell when it is being used
as described in this manual, switch the humidier
off, unplug it and have it examined by your dealer.
• Do not pour hot water into the tank, i.e. at a
temperature in excess of 40°C.
• Do not immerse the humidier or the mains cable
or plug in water or other liquids.
• Never scrape the transducer with a hard tool. The
humidier must be cleaned regularly. To do this,
refer to the cleaning instructions in this manual.
• If you spill any liquid into the humidier, it can
cause serious damage. Switch it off at the mains
immediately. Withdraw the mains plug and consult

6
INSTRUCTION MANUAL · HUMIDIFIER
EN
your dealer.
• Disconnect the humidier from the power supply
when not in use and before cleaning.
• Ensure that the mains cable does not touch any
hot surface and that it does not overhang a table
edge.
• Never use this humidier in a room where aerosol
products (sprays) are used or in a room or where
oxygen is being administered.
• Do not put items of clothing or towels on top of
the humidier. If the nozzle is obstructed, this may
cause the humidier to malfunction.
• When moving the humidier, lift it by the base and
not by the water tank.
• Do not use the humidier if the air in the room is
already sufciently humid.
• The ideal relative humidity level for human
comfort is in fact between 45% and 65%. Excess
humidity shows up in the form of condensation
on cold surfaces or cold walls in the room. To
measure the room’s humidity correctly, use a
hygrometer available in most specialist shops and
hypermarkets.
• This product is intended for indoor, non-industrial,
non-commercial, household use only.

7
HAZE ·HU-400BCA
EN
• Micro-organisms that may be present in the water
or in the environment where the appliance is used
or stored, can grow in the water reservoir and be
blown in the air causing very serious health risks
when the water is not renewed and the tank is not
cleaned properly every 3 days.
• Keep the appliance out of reach of children. Steam
and boiling water may cause burns.
• Never leave water in the reservoir when the
appliance is not in use.
• Clean the water every three
days.
• Be aware that high humidity levels may encourage
the growth of biological organisms in the
environment.
• Do not permit the area around the humidier to
become damp or wet. If dampness occurs, turn
the output of the humidier down. If the humidier
output volume cannot be turned down, use the
humidier intermittently. Do not allow absorbent
materials, such as carpeting, curtains, drapes, or
tablecloths, to become damp.

EN
8
INSTRUCTION MANUAL · HUMIDIFIER
• Unplug the appliance during lling and cleaning.
• Empty and clean the humidier before storage.
Clean the humidier before next use.
• Warning: Micro-organisms that may be present in
thewaterorintheenvironmentwheretheappliance
is used or stored, can grow in the water reservoir
and be blown in the air causing very serious health
risks when the water is not renewed and the tank is
not cleaned properly every 3 days.
• Empty the tank and rell every third day. Before
relling, clean it with fresh tap water or cleaning
agents if required by the manufacturer. Remove
any scale, deposits, or lm that has formed on the
sides of the tank or on interior surfaces, and wipe
all surfaces dry.

EN
9
HAZE ·HU-400BCA
PLACEMENT
• Place the product on rm, at surface.
• The humidier should be placed on at horizontal sur-
face and keep it steady.
• Do not place the product near or close to any heat
sources.
• The humidier should be far away from any heat sourc-
es, such as stoves or re places. Do not expose the prod-
uct to direct sunlight.
• Do not place the product near or close to furniture or
electric appliances.
• The mist outlet from the humidier should not be di-
rected towards furniture and the electronic appliances, to
avoid damage.
• Particles in water, such as calcium, can be part of the
vapour and be deposited on objects in the vicinity.
• It is recommended that the unit be placed on a table or
other surface at least 70 cm above the oor level, to en-
sure that the vapour will be optimally distributed through-
out the room.
• Air draft and temperature changes can impact the dis-
tribution of the vapor. To avoid water damage it’s recom-
mended to always check for moist accumulations on the
oor or other nearby surfaces.

10
INSTRUCTION MANUAL · HUMIDIFIER
EN
PRODUCT OVERVIEW
1. Top cover
2. Handle
3. Nozzle
4. Water tank
5. Control panel
6. Base
7. Sensor
8. Power cord
1
2
3
4
5
6
7
8

11
HAZE ·HU-400BCA
EN
OVERVIEW – DISPLAY
BEFORE USE
• Put the humidier in the room 30 minutes before starting it.
• It is recommended to use the humidier when the temperature is under
20°C, and the relative humidity is less than 80%RH.
• Use clear water not over 40°C.
• Check the water basin, make sure it is clear.
• Place the humidier on a at surface.
WATER FILTER
• Ceramic balls can soften the hard water.
• Ceramic lter can eliminate the strange smell in the water.
AROMA BOX
1. Press out aroma box from the base.
2. Use water-soluble aroma oil and drop on to the sponge.
3. Put the aroma box back into humidier, the aroma function will remain on
when the humidier is running.
4. To stop the aroma function or when storing the humidier, clean the
sponge in the aroma box.
5. Only drop aroma oil into aroma cotton. Do not drop any liquid except
clean water into water tank or basin.
OVERVIEW – CONTROL PANEL

12
INSTRUCTION MANUAL · HUMIDIFIER
EN
USE
• Remove the top cover, ll water into the water tank, and put the top cover
back on. You can also take the water tank out and ll water directly into the
tank, and put the water tank back into the main base.
• Check if the rated voltage meets the input voltage, and plug into the
socket. The display will light up and it beeps one time. 1 second later, the
display will turn off, and the “on/off” button will turn red, meaning the
humidier is in standby mode.
• Touch the “on/off” button, the display will light up, and it will start to
work in AUTO mode. The display shows the auto symbol and current
humidity. 10 seconds later, the display shows current temperature, and
then change into humidity. Current temperature and humidity showing will
change once every minute.
• Humidier will decide running humidity based on current temperature as
below.
• Constant humidity: touch the HUMIDITY button and you can select the
humidity from 30%RM to 75%. Touch the button once and it will increase
by 5%RH each time. When it reaches 75%, touch again and the display will
show “—” and the humidier will go back to AUTO mode. After setting
the preferred humidity, humidier will keep the memory and conrm by
ashing 3 seconds. Once the display switches to show current humidity, it
means that the setting is nished, “%” will ash on the display.
– When setting humidity is 1%RH~9%RH higher than current humidity, mist
output speed will run by the lowest (the rst) speed.
– When setting humidity is 10%RH~15%RH higher than current humidity,
mist output speed will run by the middle (the third) speed.
– When setting humidity is 15%RH higher than current humidity, mist
output speed will run by the highest (the fth) speed.
– When current humidity is higher than setting humidity, humidier will
turn into sleep state. Once current humidity is 3%RH lower than setting
humidity, humidier will re-work in previous working mode till water
shortage.
Temperature
of the air,
degrees
Celsius
≤19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 ≥37
Humidity (%) 65 60 58 57 55 53 50 48 45 43 40 38 36 35 34 32 31 30 25

13
HAZE ·HU-400BCA
EN
– Mist output speed is adjustable under constant humidity function.
• Night mode: Long press the humidity button for 2 seconds to shut down
the water tank indicator light and display. Only the red On/off button will
show. Press any button to wake up the light and display.
• Timer: There is 12 timer settings: 1-12. Touch the TIMER button and the
display will show the timer setting from 1-12 in sequence. For example
“1H”. Once you have found your preferred time setting, do not operate
it for 3 seconds, the time will stop ashing and the timer is set. The timer
shows the rest of the operating time every minute. Press the timer button
for 2 seconds to cancel the operation.
• Heat/Ions: Touch the Heat/Ions button once to start the heating function.
The display shows the heating symbol . Warm mist will come out after
10-15 minutes. Touch the button again to start the plasma function. The
plasma symbol will show on the display. Touch the button again to shut
down the heating function. Touch the button one more time to shut down
the plasma function. Long press the heat/Ions button to tun on/off water
tank indicator light.
• Mist output speed: Touch the bar to enter manual mode.
Slide from MIN to MAX to select your preferred mist output speed. Sliding
from left to right will increase the speed, sliding from MAX to MIN will
decrease the speed. The display shows the selected speed from 1-5.
• Auto shut down: If there is not enough water in the water tank to keep the
humidier going, the humidier will automatically stop working and stay
at standby mode. The water shortage symbol will show on the display.
Rell the water tank and press the on/off button to turn the humidier on
again. If there is too much water in the basin, the display shows EF, and
it will automatically stop working. Pour out some of the excess water and
put the water tank back into the main base, switch it on and it will work as
normal.

14
INSTRUCTION MANUAL · HUMIDIFIER
EN
TROUBLESHOOTING
Problem Possible reasons Solutions
Power lamp is off
when switched
on.
Humidier is not
plugged in.
Plug the humidier into a
powered electrical socket.
Power cord is
damaged.
Immediately discontinue
use and contact Customer
Support.
Humidier is defective
or malfunctioning.
Press the power button to
turn it on.
Power lamp is on
when switched
on, but no mist
come out.
Humidier is not
turned on.
Press the power button to
turn it on.
The target humidity is
reached.
Increase the target humidity
or change mode.
Water shortage
indicator is on.
No water in the tank. Rell the water tank wait at
least 1 minute.
Water level is low.
The water level
required has
not yet reached
the vaporization
compartment.
Wait at least 1 minute.
The water tank isn’t
well positioned.
Check the positioning of tank
on the base.
The humidier isn’t on
a at surface
Check the positioning of the
humidier.
Humidier
produces an
unusual smell
Humidier is new. Take out water tank, open
cover, let it stay 12 hours in
cool position.
Dirty water or water
sitting too long.
Clean water tank, ll with
clear water.
Residual smell from
diffusing aroma oil on
the aroma cotton.
Remove the aroma cotton,
rinse it under clean water and
allow it to dry.

15
HAZE ·HU-400BCA
EN
Humidier makes
a loud or unusual
sound.
Resonant in water tank
when water is too low.
Fill water into water tank.
Humidier is on an
unstable surface.
Move the humidier to a
stable at surface.
Water tank is
positioned incorrectly.
Turn off and unplug the
humidier, then align the
water tank cover with its
respective opening in the
inner chamber.
Humidier is
malfunctioning.
Immediately discontinue
use and contact Customer
Support.

16
INSTRUCTION MANUAL · HUMIDIFIER
EN
The
humidication
capacity is too
low.
There is natural
or articial air
replacement in the
room which interfere
the increase of %RH.
Check if doors and windows
are closed.
Check if there is no air
conditioning working in the
room.
The air inlet grids,
and nozzle could be
blocked.
Remove any blocking items
from the grids and the nozzle.
Too much scale in the
water basin.
Clean transducer.
The humidity selected
rate is too low.
Increase mist output speed.
Increase humidity setting
rate.
Water is too dirty, or
water is kept too long
in the tank.
Clean water tank, change to
fresh clear water.
The ambient
humidity is too
high.
Humidier is working
in CONTINUOUS
MODE.
Change the mode.
The humidity target is
too high.
Select a lower %RH target.
Room is not well-
ventilated.
Open a window to ensure
proper air ow for your
humidier or move the
humidier to a more well-
ventilated room.
Excess water tank has
spilled while lling the
water tank or replacing
the water tank back
onto the base.
Wipe off excess water from
the top and bottom of the
base before replacing the
water tank.
There is
condensation in
the room.
The room temperature
is too low.
Heat the room up.

17
HAZE ·HU-400BCA
EN
The mist suddenly
stops coming out.
Programmed timer
period has run out.
Turn humidier on.
The water shortage
indicator is on.
Rell water tank.
The target humidity
level is reached.
Turn the humidier off, or
select a higher humidity level.
Incorrect humidity
level is being
displayed.
Room is larger than the
effective range of the
humidier.
Move the humidier to a
room which is with suitable
room size.
Moisture has built up
inside of the humidity
sensor.
Turn off the humidier and
allow the humidity sensor
to completely air dry before
resuming use.
The nozzle is facing
the direction of the
humidity sensor.
Turn the nozzle so that it
is facing away from the
humidity sensor.
Humidity sensor is
broken of defective.
Contact Customer Support.
Control panel
does not work.
Hands are too wet
when operating control
panel.
Keep hands dry while
operating the control panel.
Humidier has
malfunctioned.
Contact Customer Support.
White dust
appears around
the humidier.
Water being used has
a high mineral content.
Use distilled water with the
humidier. If distilled water is
not available, use puried or
ltered water.
Humidier was not
properly cleaned after
last use.
Clean humidier.
Mist is coming
out from the
base.
Water tank is not
positioned correctly.
Turn off and unplug the
humidier, then align the
water tank cover with its
respective opening in the
inner chamber.

18
INSTRUCTION MANUAL · HUMIDIFIER
EN
Mist fog coming
out from around
nozzle.
There are apertures
between the nozzle
and water tank.
Reposition the cover and
check if the nozzle is well
plugged in the cover.
The warm mist
function does not
produce warm
mist.
The humidier is in
warm-up phase.
Wait a few minutes till the
end of the phase.
The mist is too ne to
feel the warmth.
Increase the speed level.
The room temperature
is too cold, and the
mist may cool down
too quickly.
Increase the speed level and
heat the room up.
Display show
error code EF.
Too much water in
water basin.
Remove water tank and
empty water from the base.
Check and clean particles
in water outlet of water tank
that led to leakage. If no
leaks, replace into base.
The following is not considered faulty operation:
• If your water is very hard (containing abnormally high levels of minerals)
the humidier may produce white dust. This is not a malfunction. The
solution would be to clean the lter more often or use softer water.
• If you stand very close to the humidier, you will hear the gurgling sound
of water. This is normal.
• The humidier operates very quietly but it is not completely silent. Noise
levels less than 35dB(A) is considered normal.
MAINTENANCE
In case the water is hard, meaning the water contains too much calcium and
magnesium, it can cause a “white powder” problem and leave heavy scales
on the surface of water basin, transducer, and inner surface of the water tank.
Scales on the surface of transducer will let the humidier work improperly.
Empty the tank and rell every third day. Before relling, clean it with fresh
tap water or cleaning agents if required by the manufacture. Remove any
scale, deposits, or lm that has formed on the sides of the tank or on interior
surfaces and wipe all surfaces dry.
This manual suits for next models
1
Table of contents
Languages:
Other Wilfa Humidifier manuals