XPR Access EWS-DR User guide

1
EWS-DR/ EWSi-DR
2 Doors/2 Readers Access Control Unit
SPECIFICATIONS
INSTALLER MANUAL
va.1
Power Supply: 12VDC
User/Event capacity: 1000/30000, 4000/24000, 8000/16000, 12000/8000 or 15000/2500, configurable by soware
Communicaon: EWS-DR -RS485, EWSi-DR -RS485 and TCP/IP
Door relays: 2 (250 VAC, 10A)
Programmable Outputs: 2 (250 VAC, 10A)
Readers: 2
Programmable Inputs: 2, optocoupled, ON level 5-30VDC (3-28mA)
Door sensors: 2
Exit Buon Inputs: 2
Wiegand interface: Programmable (8 to 128bit), 32databits, 4 parity bits
Environment temperature: 0 - 45 C
Humidity: 0-80 %, non condensing
Consumpon: EWS-DR 200mA, EWSi-DR 250mA (without readers)
Fuse protecon: 1A thermal fuse for total consumpon of the controller and readers.
+
-
Power
Supply
12V out
-
-
1N4007
Electro Magnetic Lock
+
-
Lock
Power
Supply
1N4007
Electric Door Strike
(DC powered)
+
-
+
-
DC
Electric Door Strike
(AC powered)
C
R 10K
470NF
AC
POWER
12 VDC
TAMPER
I/O
COM
NOT FOR PoE!
READER 2
OUTPUT 1
DOOR 2
DOOR SENS
& EGRESS 1
+
-
12V
COM
TCP
UDP
D1 D2 O1 O2
TX
RX
SYS 1
SYS 2
Fingerprint
reader
Door Sensor
(NC, mechanical or
relay dry contact)
Exit Button
(NO, mechanical or
relay dry contact)
Default IP: 192.168.1.100
port: 4001
+
-
5 - 30V Reset IP
(press and hold for 3sec
to reset the IP, the port
and the network password)
Battery
(CR2032)
Card reader Green
Orange
Black
Red
White
Yellow
Violet
Pink
For I/O0408
relay board
Green
Orange
Black
Red
White
Yellow
READER 1
DOOR SENS
& EGRESS 2
DOOR 1
OUTPUT 2
INPUT 1
INPUT 2
TCP/IP
RS485
DIPSWITCH
pin1:for termination
of the RS485 cable
on the terminal
block pins A and B
pin2:for termination
of the I/O COM port
on the terminal block
pins
EARTH- fixing holes for
earth connection
12V
COM
TCP
UDP SYS2
SYS1
RX
TX
D1 D2 O1 O2
Transmit/Receive
SYSTEM OK (Heartbeat)
Ethernet
Power supply
Communication
DOOR 1/2 OUTPUT 1/2
Schematic of the EWS-DR
input optocoupler
IN1+
+
GND
IN1-
IN2+
IN2-
1k
EWS-DR
+
GND
IN1+
+
T
D1
D0
LED2
LED1
PB1
DS1
D1
D0
PB2
DS2
GND
GND
GND
GND
GND
GND
12V
12V
12V
IN1-
IN2+
IN2-
LED1
LED2
COM
COM
COM
COM
NC4
NC2
T2
T1
NC3
NC1
B
B
A
A
NO4
NO2
NO3
NO1
Com
Com
IP
Reset
TCP
netw
ork
62mm
91mm
161mm
EN

2
1. Connect the devices according to the connecon diagram above.
2. Use the diodes provided when the door lock is DC powered or the capacitor with 10K resistor when the lock is AC powered.
3. Use the Dipswitch pin1 for RS485 tuning.
4. Insert the baery provided with the hardware kit.
5. Connect the power.
INSTALLATION
RS485 TUNING
IMPORTANT NOTE:
- The RS485 Communication Line must be made in daisy chain, NOT in a star type configuration.
- The cable must be twisted and shielded. Connect the EARTH to the shield.
- Connect the COM to each unit in the RS 485 line.
- Terminate both ends of the line with 120 Ohm resistor. If end of line is EWS-DR, use built in resistor (120 ohm) by turning the Dipswitch pin1 ON.
1 km max / 32 Units (EWS and Biometric Readers)
Put the Dipswitch pin1 in ON position, on the first and last controller
in the RS 485 network, to set 120ohm resistance
between terminal pins A and B.
BIOC3 B100
com
com
com
com
CHANGING THE IP ADDRESS OF EWS(i)-DR
With PROS CS:
The default IP of the controller is 192.168.1.100
To change the IP of the EWS controller:
1. Connect the EWS controller directly to the PC.
2. Change the IP of your PC to 192.168.1.200
3. Go in the Soware and in the hardware window, right click on the Portals item, then select Search Network Portals. When the Search portals window is opened, hit
Search.
4.Click on the “Setup” buon.
Setup Portal window is opened, and now you can set values for the parameters in the portal setup. Further you have the parameters of the setup explained.
PROS Software
Switch, Router
TCP/IP max. 90m. RS 485
TCP/IP
RS485 - USB Converter
RS 485
COMMUNICATION MOUNTING ТHE PCB
87mm
74mm
140mm
175mm
71mm
PCB can be mounted directly on the panel. In this case, use provided
spacers for fixing and printed screen for protecon.
Use nylon spacers only,
for these holes. 7mm
15mm
PCB
Mask
43mm 43mm

3
6. Put back the IP of your PC to the previous IP address.
With Web browser:
- Change the IP of your PC to 192.168.1.200
- Connect the EWS controller and type in the browser 192.168.1.100 ( username: admin, password: 00000000) and change the IP from there
- Put back the IP of your PC to the previous IP address
IP: Portal IP address.
Setup Port: Used for searching the portals of the network.
Password: For searching and configuring the portals.
Mask: IP Mask.
Gateway: Network Gateway.
MAC: Mac portal.
DHCP enable: It is recommended that DHCP is disabled and fixed IP value is used.
DNS: Domain name server. Recommended to keep zeros.
Data port: Port value for communicaon between soware and devices (controllers, readers) connected to the portal.
Dedicated client: If enabled portal will connect only with soware on computers that are matching the dedicated IP or
dedicated MAC value. This parameter affects only communicaon between server soware and portal. Computers that
are running client soware are not affected, as client soware is connected only to server soware and not with portals.
Dedicated IP: Valid if dedicated client is enabled.
Dedicated MAC: Valid if dedicated client is enabled.
Enable web interface: If enabled, portal configuraon can be done by web browser using IP and Web port as an address.
( ex. If the port IP is 192.168.1.100 and Web port is 80, the web address for setup is hp://192.168.1.60:80 )
Version: Firmware version of the portal. If newer version is available, it will be distributed with the latest release of the
access control soware.
For upgrading the firmware check the manual of the access control soware.
5. Change the portal IP address, and press Send sengs.
ADDING EWS(I)-DR CONTROLLER IN THE SOFTWARE
In order the controller to communicate with the software, the controller must be added in the software with its Serial Number. The serial Number is written on the controller itself,
but it can be also searched when the controller is connected to PC.
1. Right click on Portals and select “Search Network Portals”
2. The Software will find all the IP’s of the controllers that are connected to the network
3. Click on “Add”
4. Right click on the newly added portal and “Search devices” for Controllers. The software will find all the Serial Numbers of the controllers that are connected under that IP
address.
5. Click on “Add New” and the controller will be added. Put a name for the controller and “Save and Exit”. From then on the controller should be on line.

4
Note: If the Controller/Portal can not be added automacally by search opon, add them manually.
For any other feature, see the HELP File located whithin the soware itself
TROUBLESHOOTING
1. Reader is not reading the card.
-Check the power supply at reader. If the voltage is low use addional wires for power supply.
-Check the connecon of the wires in EWS-DR reader terminals.
-Check if the card type match the reader or the readers card type setup.
-Check for correct wiring.
2. Reader is reading the card, but no reacon from the controller or access event in the soware.
-Check in soware if readers Wiegand seng match the reader Wiegand output.
-Check if cable length is within the specificaons of the reader. If reader is working with short cable then the problem is voltage drop on power supply lines. In this case use
free wires as addional power supply lines for the reader. If you have only one free wire use it to improve the 0V line.
3. Communicaon via RS 485 line is inconsistent or non-exisng ( in the soware, controller is switching online/offline status).
-Check if A and B lines are correctly connected at all terminals/devices.
-Check if one of the RS 485 lines is disconnected at some point.
-Check terminaon configuraon of RS 485 line in all devices.
4. Controller loses me and users aer mains power failure.
-Replace the controller coin baery (Cr2032).
-Always use power supply with baery charger and baery of at least 4 Ah.
5. Soware cannot connect to controller via TCP.
-Make sure there is no other device with the same IP address in the network.
-Make sure there is no other soware communicang with the controllers.
-Check with the WEB interface of the EWS-DR if the sengs are correct.
6. Searching portals in soware shows only some or none of the portals.
-In the soware under sengs/system parameters disable the item “use default PC network interface only’.
7. Controller does not perform some opons configured by soware.
-Check the controller firmware by right-clicking on the controller icon and selecng “Check version item”. Upgrade the firmware by right-clicking on the controller icon and
select “Firmware upgrade item”.
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS directive
EN50581:2012