XPR Access WS4-4D-E Instruction manual

www.xprgroup.com 1
EN
WS44DE
4 Door access control unit with web access
DESCRIPTION
SPECIFICATIONS
FACTORY RESET
CHANGE PASSWORD
SOFTWARE SETTINGS
METHOD 1
ADDING READERS
METHOD 2
ADDING USERS
ADDING SLAVE CONTROLLERS
FIRST CONNECTION AND CONFIGURATION
If you can not connect, it is because your network does not recognize the name of the
WS44DE controller. In this case, go to our web site http://www.xprgroup.com/products/ws4/
and download the tool called “Device Finder”.
The “Device Finder” will enable you to ind out the IP address of the WS44DE controller.
Run the “Device Finder” and you will get a list of all the WS4 controllers connected in
your network, including their IP addresses, just like the picture below.
To add 2 readers on 1 Door, select the reader (ig.2) and there, for “Type of Access”
select “Access with 2 readers” (ig 5). Fill the form for both readers and they will
merge in one door (ig. 6)
WS4 system can manage up to 10 WS4 boards in the same installation (with up to 20
doors, whether single or double). One WS44DE must be master, the others must be
slaves. The master/slave selection is made with Dip-switch 2: OFF - Master (factory
setting), ON - Slave.
Go to “Doors” and click on the link “Add slave”(ig.1). Enter the serial number of the
WS44DE to be added and click Search. If it inds it, the system directly adds this slave
into the installation and you can conigure its doors (ig.2).
In case of error, a message is displayed in red.
Go to Users (ig.1), select “New”(ig.2) and then ill the form (Name, category, card
number...)(ig.3).
Open a browser and type the IP of the WS44DE controller and you will be prompted to the
login page.
User Name: admin
Password: WS4 followed by Dash and the Serial Number (ex. WS4110034) just like the
image below, all in capital letters without space.
QUICK USER GUIDE
• Capacity: 2500 Users
• Events: 50000 max.
• Doors: 4 (max. 20 doors in same network)
• Readers: 4
• Door contact inputs: 4
• Push button inputs: 4
• Auxiliary Inputs: 2 (emergency, vehicle detection)
• Auxiliary Outputs: 2 (alarm, storing alarm status, presence)
• Power supply: 120 to 240 V AC, 100 VA1.52A with fuse (1 A)
• Supply for the readers: 225 mA each max.
• Supply for the locks: 600 mA each max.
• Relay characteristics: 2A/48 VAC/DC#
• Processor: ARM A5 - 528 Mhz
• Memory: 64 MB Ram DDR2 133 Mhz
• TCP/IP connection: 10/100/1000 Base-T – HTTP or HTTPS
• Dimensions (mm): 116 x 195 x 33 mm
• Operating temperature: 0 °C to +50 °C
• Humidity: 0% to 85% (non-condensing)
• Tamper: Yes
• Wiegand readers connection: Yes, via Wiegand to RS485 converter - WS4CNV
• Elevator feature: Yes, 2 elevators per installation, each - 24 loors
• Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
The WS44DE does not have default IP address. By default is set to DHCP. There are 2
methods to connect to and conigure WS44DE - LAN and Standalone method.
In this coniguration, the network’s DHCP server will assign an IP address to your WS44D
In this coniguration, the WS44DE will assign an IP address to your PC. The PC must be set to obtain IP
address automatically.
(For use in a home or business LAN network)
(For standalone use - without LAN network)
1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of WS44DE.
3. Open a web browser and enter http://ws4 followed dash and the serial number of
the WS44DE controller
1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS44DE.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login
credentials like explained above
DIP Switch 4 allows a complete re-initialization of the system. To
do this, switch this dip switch 3 times OFF - ON - OFF within 10
seconds.
DIP Switch 4 allows to log into the system as an administrator if
login or password is forgotten. Toggle this dip switch ON for
about 15 seconds, then back to OFF. The system will then allow,
for 5 minutes, to connect (from the local network only) with the
default login and password.
Go to “Doors”, select the reader(ig.2) and then select the type of the reader in the
ield ”Card”. (ig.3). While o line, red LED blinks fast and buzzer beeps continuously.
Once communication is established, the red LED and the buzzer stop. Green LED
starts to blink continuously. If you want to stop the green LED, go to Settings/System
Options and select for the backlight ON or OFF (not default) ig.4
v.a2
ig.1
ig.3
ig.5
ig.1
ig.2
Switch
Master/
Slave
Master
DIP switch 2
OFF
Slave 1
DIP switch 2
ON
Slave 9
DIP switch 2
ON
ig.3
ig.6
ig.4
ig.2
ig.1
ig.2
WS44DE is a 4 door control unit designed to operate with readers with RS485 output.
There is no need to install any software. There is no need to have a dedicated PC
either. Everything is available online and the operators just need to register with
controller’s serial number to start using the software application.
NLDE
ES
IT
FR
EN
www.xprgroup.com 2
EN
Connection example of 3 doors
Door contact
OUT IN electric strike (fail close)
Emergency
button Box Tamper
Push button
Push button
Electromagnetic Lock 12V/600mA max
Address 0
12V/600mA max
Reader
Reader
Door contact
Address 1
electric strike (fail open)
Network
Alarm siren
or
lash siren
Power supply 14,2V
See user manual
12V battery
12V/600mA max
Address 0 Address 1
Example of a door with 2 readers + electric strike fail close
1. The readers for Doors 1.0 and 2.0 must be at address 0 and
those for Doors 1.1 and 2.1 at address 1.
2. For doors equipped with 2 readers, one must be at address
0 and the other at address 1.
3. The function of OUT1 and OUT2 can be conigured in the
software
4. In1 & In2: Connect to GND by a volt-free contact to activate
the input
5. LIYCY cable, twisted pair, up to 80m.
If more than 80 m. are needed, then termination resistors(120
ohm) may be required at both ends of the RS485 line, while
taking into consideration the lengths proposed on our web
site.
6. Alarm cable 2x0,22
7. The cross section of the cable depends on the current
needed by the lock
Note: The elevators relay boards (WS4RB12) are connected
on the same Rs485 lines as the readers.
This product herewith complies with requirements of EMC directive 2014/30/EU.
In addition it complies with RoHS2 directive EN50581:2012
Example of a door with 1 reader + electric strike fail open
Example of a door with 1 reader + electromagnetic lock

Other XPR Access IP Access Controllers manuals

XPR Access EWS-DR User guide

XPR Access

XPR Access EWS-DR User guide

XPR Access WS4-1D-E Instruction manual

XPR Access

XPR Access WS4-1D-E Instruction manual

XPR Access XPROX User manual

XPR Access

XPR Access XPROX User manual

XPR Access WS4-2D-E Instruction manual

XPR Access

XPR Access WS4-2D-E Instruction manual

XPR Access WS4-4D Instruction manual

XPR Access

XPR Access WS4-4D Instruction manual

Popular IP Access Controllers manuals by other brands

Alvarion BreezeACCESS EZ AU-EZ System manual

Alvarion

Alvarion BreezeACCESS EZ AU-EZ System manual

Siemens ADE5300 installation manual

Siemens

Siemens ADE5300 installation manual

Bpt HNA/102 installation instructions

Bpt

Bpt HNA/102 installation instructions

TCS codelock12 Product information

TCS

TCS codelock12 Product information

Soyal AR-721U Hardware operation guide

Soyal

Soyal AR-721U Hardware operation guide

ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating and installation instructions

ACT

ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating and installation instructions

Rosslare AC-215 Hardware installation guide

Rosslare

Rosslare AC-215 Hardware installation guide

Delta Controls ASM-24 Installation & Application Guide

Delta Controls

Delta Controls ASM-24 Installation & Application Guide

Invixium TITAN Installation

Invixium

Invixium TITAN Installation

ATLO ATLO-FR-601 user manual

ATLO

ATLO ATLO-FR-601 user manual

Transmitter Solutions Dolphin DOLCWIUHF-ER-902 manual

Transmitter Solutions

Transmitter Solutions Dolphin DOLCWIUHF-ER-902 manual

Dahua DHI-ASI7213Y-V3-T1P user manual

Dahua

Dahua DHI-ASI7213Y-V3-T1P user manual

Interlogix ACL800-BS-USB installation manual

Interlogix

Interlogix ACL800-BS-USB installation manual

GVS H Series user manual

GVS

GVS H Series user manual

ZKTeco Notus user manual

ZKTeco

ZKTeco Notus user manual

NEXT Biometrics NB-3020-U2 installation guide

NEXT Biometrics

NEXT Biometrics NB-3020-U2 installation guide

Cidron Standard Reader installation guide

Cidron

Cidron Standard Reader installation guide

Schlage Panel Interface Module RS485 Installation & operating instructions

Schlage

Schlage Panel Interface Module RS485 Installation & operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.