York YFGE36BXOXBH-RX User manual

INSTALLATION AND OWNER’S MANUAL
No.
Please read this manual carefully before using this air conditioner
Please keep this manual safely for future use
YFGE36BXOXBH-RX
YFGE48BXOXBH-RX
YFGE55BXOXBH-RX
0150521923


DC282AFEAA DC362AFEAA DC482AFEAA DC602AFEAA
DC282AFERA DC362AFERA DC482AFERA DC602AFERA
CE
All the products are in conformity with the following European provision:
-Low Voltage Directive 73/23/EEC
-Low Voltage Directive 2006/95/EC
-Electromagnetic CompatibilitY 89/336/EEC
ROHS
The products are fulfilled with the requirements in the directive 2011/65/EU of the
European parliament and of the council on the Restriction of the use of Certain Haz-
ardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
.
WEEE
In accordance with the directive 2012/19/EU of the European parliament,
herewith we inform the consumer about the disposal requirements of the
electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this sym-
bol. This means that electrical and electronic products
shall not be mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dis-
mantling of the air conditioning system, treatment of
the refrigerant, of oil and of other part must be done
by a qualified installer in accordance with relevant
local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed of correctly, you
will help to prevent potential negative consequences for the environment and
human health. Please contact the installer or local authority for more infor-
mation. Battery must be removed from the remote controller and disposed of
separately in accordance with relevant local and national legislation.
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS:
1
1+2= kg
R410A
2kg
2=
1= B
C
D
FE
kg
Containsfluorinated greenhouse gases
covered by the Kyoto Protocol A
This product contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Do not vent into the atmosphere.
Refrigerant type: R410A
GWP:
2088
*
GWP = global warming potential
Please fill in with indelible ink,
•1 the factory refrigerant charge of the product
•2 the additional refrigerant amount charged in the field and
•1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product charging
port (e.g. onto the inside of the stop valve cover).
Acontains fluorinated greenhouse gases covered by the Kyoto Protocol
Bfactory refrigerant charge of the product: see unit name plate
Cadditional refrigerant amount charged in the field
Dtotal refrigerant charge
Eoutdoor unit
Frefrigerant cylinder and manifold for charging
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED

2
Contents
Cautions
Safety Precautions
Features and Functions
Parts and Functions
Operation
Maintenance
Operation Tips
Troubleshooting
Installation Procedure
Test Run
3
5
6
8
10
12
12
13
17
24

3
Cautions
Disposal of the old ai conditione
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe Unplug the air
conditioner in order to avoid the risk of child entrapment
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal The valuable
materials contained in a air conditioner can be recycled Contact your local waste disposal center for proper disposal of an old
air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of
your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to
environmental awareness by insisting on an appropriate, anti-pollution method of disposal
Disposal of the packaging of you new ai conditione
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the
environment
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag
made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal
services nearest to your house
Safety Inst uctions and Wa nings
Before starting the air conditioner, read the information given in the User's Guide carefully The User's Guide contains very
important observations relating to the assembly, operation and maintenance of the air conditioner
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following
instruction
Damaged air conditioners are not to be put into operation In case of doubt, consult your supplier
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide
Installation shall be done by professional people Don't install unit by yourself
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications
Always remember to unplug the air conditioner before opening inlet grill Always grip plug firmly and pull straight out from the
outlet
All electrical repairs must be carried out by qualified electricians Inadequate repairs may result in a major source of danger for
the user of the air conditoiner
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes
with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces If the refrigerant spurts
out and gets into eyes, it may result in serious eye injuries
Do not obstruct or cover the ventilation grille of the air conditioner Do not put fingers or any other things into the inlet/outlet and
swing louver
Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit
When the indoor unit is turned on, the PCB will test if swing motor is O K , and then fan motor will start up So there is a few
seconds to wait
In cooling mode,the flaps will swing automatically to a fixed position for anti-condensating

If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate
to prevent internal circuit damage Also, during Cooling and Dry modes, if the unit is used under conditions of lower
temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage
Do not use this unit for purposes other than cooling, heating, dehumidifying and ventilation of rooms in ordinary dwellings
The wiring method should be in line with the local wiring standand
The waste battery should be disposed properly
If the fuse on PC board is broken, please change it with the type T 3 15A/250VAC
4
Cautions
Cooling
Heating
Indoor temperature
Outdoor temperature
Indoor temperature
Outdoor temperature
max DB/WB
min DB/WB
max DB/WB
min DB/WB
max DB/WB
min DB/WB
max DB/WB
min DB/WB
ON-OFF Inverter
32/23 C
18/14 C
43/26 C
10 C
27 C
15 C
24/18 C
-7 C
32/23 C
18/14 C
43/26 C
-5 C
27 C
15 C
24/18 C
-
15
C
Tempe atu e and Humidity Range
Specifications
The refrigerating circuit is leak-proof
For all the models in this manual, the all-pole discon-nexion connection method should be applied in the power supply
Such means for disconnection must be incorporation in the fixed wiring

WARNING
DANGER
5
Safety P ecautions
The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be no less
3 mm Such means for disconnection must be incorporation in the fixed wiring
Use copper wire only All the cables shall have got the European authentication certificate
The power supply connects from the outdoor side The connecting cable and the power cable are self-provided
The parameter of connecting cable: H05RN-F 4G 0 75mm2
WARNING
Do not attempt to install this air conditioner by yourself
This unit contains no user-serviceable parts Always consult authorized service personnel for repairs
When moving, consult authorized service personnel for disconnection and installation of the unit
Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow
Do not insert fingers or objects into the outlet port or intake grills
Do not start and stop air conditioner operation by connecting and disconnecting the power supply cord and so on
Take care not to damage the power supply cord If the supply cord is damaged, it must be replaced by the manufacturer
or authoried service agent in order to avoid a hazard
In the event of a malfunction (burning smell, etc ), stop operation immediately, turn off the circuit breaker, and consult
authorized service personnel
Provide occasional ventilation during use
Do not direct air flow at fire places or heating apparatuses
Do not place objects on the air conditioner or climb onto it
Do not hang objects from the indoor unit
Do not set flower vases or water containers on top of the air conditioner
Do not expose the air conditioner directly to water
Do not operate the air conditioner with wet hands
Do not pull power supply cord
Turn off power source when not using the unit for extended periods
Check the condition of the installation stand for damage
Do not place animals or plants in the direct path of the air flow
Do not drink the water drained from the air conditioner
Do not use in applications involving the storage of foods, plants or animals, precision equipment or art works
Do not apply any heavy pressure to radiator fins
Operate only with air filters installed
Do not block or cover the intake grill and outlet port
Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor unit
Avoid installing the air conditioner near a fireplace or other heating apparatuses
When installing the indoor and outdoor unit, take precautions to prevent access to infants
Do not use inflammable gases near the air conditioner

AUTOMATIC OPERATION
SLEEP
COOLING TYPE
When the SLEEP button is pressed during Cooling or Dry mode, the thermostat setting gradually rises during the period
of operation When the set time is reached, the unit automatically turns off
HEAT & COOL TYPE
When the SLEEP button is pressed during Heating mode, the air conditioner's thermostat setting gradually lowers during
the period of operation; When the set time is reached, the unit automatically turns off
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation For this type unit, the
wireless remote controllor type is YR-H50
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care
COOLING TYPE
Merely press the ON/OFF button, and the unit will begin automatic operation in the Cooling or dry modes as appropriate,
in accordance with the thermostat setting and the actual temperature of the room
HEAT & COOL TYPE
Merely press the ON/OFF button, and the unit will begin automatic operation in any of the Heating, Cooling and Blow
modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room
VERTICAL AIR DIRECTION ADJUSTMENT
Use the air direction adjustment within the ranges shown above
The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected
Each time the button is pressed, the air direction range will change as follows:
Press the AIR FLOW DIRECTION VERTICAL SET button
1 2 345
5 4 321
Cool/Dehumidification/Fan:
Heat:
1
2
3
4
5
6
Featu es and Functions

Each time the button is pressed, the air direction range will change as follows:
air direction louvers
RIGHT/LEFT
12 3 45
32124 154 5
1
2
3
4
5
Air flow direction set Range of swing
1
2
3
4
5
1
1
2
3
1
to
3
to
3
to
4
to
5
to
5
(all range)
Note :
When being switched on firstly, the up-down flap will be at the position of max angle In cooling, the up-down louver is not
good to stay at position 4, 5 for a long time, otherwise, the dew will occur
HORIZONTAL AIR DIRECTION ADJUSTMENT
Press the AIR FLOW DIRECTION HORIZONTAL SET button
123
4
5
Use the air direction adjustments within the ranges shown above
The swing range of up-down flap is as follow :
7
Featu es and Functions

(1) Operating Control Panel
(2) Emergency Switch
(3) Power Indicator Lamp
(4) OPERATION Indicator Lamp
(5) TIMER Indicator Lamp
(6) Compressor Lamp
(7) Remote Receiver
(8) Inlet Grill ( Filter inside )
(9) Front Panel
8
91
Note :
For the wired control type unit, the unit state should be checked by the wired controller, instead of the remote receiver
And if you set the TIMER function, the TIMER LED on the remote receiver will not be on
8
Pa ts and Functions
Indoo unit
POWER OPER TIMER
EMER
COMP
1
34 5 6 7
2

9
Parts and Functions
2.Select operation mode
Press F N SPEED button. For each press, fan speed
follows:
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
Remote controller:
Press button
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
ir conditioner is running under displayed fan speed.
When F N is set to UTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
LOW MED HI UTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
TEMP+
TEMP-
TEMP+ TEMP-
/
Base Operation
Remote controller
changes as
SPEED
Operation
Mode
UTO
etomeR
rellortnoC Note
COOL
DRY
F N
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of F N setting.
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.
air conditioner automatically adjusts the fan speed
temperature.
When F N is set to UTO, the
according to room
In F N operation mode, the unit will not operate in
COOL or HE T mode but only in F N mode , UTO is
not available in F N mode. nd temp.setting is disabled.
In F N mode,SLEEP operation is not available.
Display
Board
UTO COOL DRY F N HE T
HE T

10
O eration
Sleep Operation
If the wind speed is high or middle before
setting for the sleep, set for lowing the wind
speed after sleeping.
If it is low wind, no change.
5.Set the wind speed change when sleeping
Use of SLEEP function
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts SLEEP operation stops
SLEEP
operation starts
SLEEP
operation stops
pprox.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises 1OC
Rises 1OC
Rises 1OC
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HE T mode
Decreases 2OC
Decreases 2OC
1 hr
2.
3.
In HE T mode
In UTO mode
4. In F N mode
It has no SLEEP function.
Note
When TIMER function is set, the sleeping function
can't be set up . fter the sleeping function is set up,
if user resets TIMER function, the sleeping function
will be cancelled;the machine will be in the state of
timing-on.
POWER/SOFT Operation
Before going to bed,you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring
you a sound sleep.
fter the unit starts,set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.
1 hours after SLEEP mode starts,temp.will become
1 higher than temp.setting. fter another 1 hours,
temp.rises by 1 futher.The unit will run for further
6 hours then stops Temp. is higher than temp.
setting so that room temperature won
be too low
for your sleep.
1 hours after SLEEP mode starts,temp will
become 2 lower than temp.setting. fter
another 1 hours,temp decrease by 2
futher. fter more another 3hours,temp.rises
by 1 futher.The unit will run for further 3
hours then stops.Temp.is lower than temp.
setting so that room temperature won
be
too high for your sleep.
The unit operaters in corresponding sleep mode
adapted to the automatically selected operation
mode.
OC
OC
OC
OC
OC
(1) POWER Operation
(2) SOFT Operation
Press POWER/SOFT button again ,POWER or SOFT
disappears.
To cancel POWER or SOFT operation
Note £”
When you need rapid heating or cooling, you can use this
function. In COOL mode, fan speed automatically takes
high speed of UTO fan mode. In HE T mode, fan speed
automatically takes medial speed of UTO fan mode.
You can use this function when silence is needed for
rest or reading. In SOFT operation mode, fan speed
automatically takes low speed of UTO fan mode.
During POWER operation, in rapid HE T or COOL
mode ,
distribution. Long period SOFT operation will cause
effect of not too cool or not too warm.
NOTE:
Cooling only unit do not have displays and functions
related with heating.

11
O eration
Set clock correctly before starting TIMER operation.
1. fter unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
BL NK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press TIME+ /TIME- button to set time.
It can be adjusted within 24 hours.
4. fter setting correct time, press SET button to confirm
" "or" " on the remote controller stops flashing.
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode
disappears.
Hints:
fter replacing batteries or a power failure happens, time
setting should be reset.
Remote controller possesses memory function,when use
TIMER mode next time, just press SET button after mode
selecting if time setting is the same as previous one.
ccording to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
Timer On/Off On-Off Operation
Healthy airflow Operation
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
1).Press the button of healthy airflow, appears on the
display. Horizontal airflow sending. void the airflow
blows direct to the body.
2).Press the button of healthy airflow again, appears on
the display. Downward airflow sending. void the airflow
Note:
1. fter setting the healthy airflow function, the position
grill is fixed.
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .
3.The cancel of the healthy airflow function
Press the button of healthy airflow again,
the unit goes on
working under the condition before the setting of healthy
airflow function.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
blows direct to the body.
2.In heating, it is better to select the
3.In cooling, it is better to select the
mode.
mode.

Inst uctions elating to heating a e applicable only to "HEAT & COOL TYPE"
Heating Pe fo mance
Mic ocompute -cont olled Automatic Def osting
This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors
As a result, the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating
perfomance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating
appliance
Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time
may be required after first starting the air conditioner until the room is heated
When using the Heating mode under conditions of low outdoor air temperature high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance
In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Automatic
Defrosting function If frost forms, the air conditioner will temporarily stop, and the defrosting circuit will operate briefly
(for about 7 to 15 minutes)
Clean the ai filte
Pull the filters upward to remove them from the Intake Grill
Clean the air filter: Remove the dust from the filters by vacuum cleaner or washing
them After washing, allow the air filters to dry thoroughly in an area protected from
sunlight
Re-attach the air filters to the Intake Grill Press the two buttons on the filters until
you hear a sound of click
12
Maintenance
When used for extended periods, the unit may accumulate dirt inside, which reduces its performance We recommend
that the unit is inspected regularly, in addition to your own cleaning and care For more information, consult authorized
service personnel
When cleaning the unit's body, do not use water hotter than 40 C, harsh abrasive cleansers, or volatile agents like
benzene or thinner
Do not expose the unit body to liquid insecticides or hairsprays
When shutting down the unit for one month or more, first allow the Fan mode to operate continuously for about half a
day to allow internal parts to dry thoroughly
Maintenace of indoo units
Ope ation tips
1
2
3

13
T oubleshooting
Followings a e not p oblems
Sound of water flowing is not a problem
Sound of cracking is heard
Smell are generated
During operation, white fog or steam
comes out from the indoor unit
No outlet air or fan speed can't be changed
in dry mode
In cooling operation, unit switches to
blowing operation
Won't start?
In heating operation, water or steam
are blown out of outdoor unit
In heating operation, indoor fan won't stop
even if unit is stopped
During unit operation or at stop, a swishing or gurgling noise may be heard
This noise is generated by refrigerant flowing in the system
Unit will not restart after stop
During unit operation, a cracking noise may be heard
This noise is generated by the casing expanding or shrinking because of
temperature changes
This is because the system circulates smells from the interior air such as
the smell of cigarettes or the painting on the furniture
When unit is running at places like restaurant, etc where dense edible oil
fumes always exist, this will happen
To prevent frost from accumulating on indoor heat exchanger, unit will switch
to blowing operation for a while then resume cooling operation
Though ON/OFF button is set to ON, the unit won't
resume cooling, dry or heating operation in 3 min
after it is stopped, this is because of
3-min-delay protection circuit
Please wait 3 minutes
Unit will reduce fan speed repeatedly and automatically if room temp is
too low in dry operation
This occurs when frost accumulated on the outdoor unit is removed
(during defrosting operation)
After unit stop, indoor fan will go on running until indoor unit cools down

14
T oubleshooting
Before ask for services, please first check your unit against the following
If your unit still can't work properly after above mentioned checks, or following problems occur, please stop it immediately
and contact your dealer
Fuses or circuit breakers often blow out
Water comes out in cooling/dry operation
Operation is abnormal or sound is heard
Ai conditione won't sta t.
Poo cooling o heating
Is power supply switch turned on?
Power supply switch is not set at ON
Is city power supply normal? Is leakage current breaker activated?
This is very dangerous, please
disconnect power supply immediately
and contact your dealer
Are operation control adjusted
correctly as specified?
Is air filter too dirty? Are there any obstacles in inlet or
outlet grill?
Are horizontal louvers at up position
(in heating mode)?
Any doors or windows left open?
Is there any direct sunlight in the room? If there are unexpected heat sources
in the room?
Too many people in the room?
Poo cooling
Cold air blows out (in heating mode) Is air conditioner in standby condition in heating mode?
Power
failure?
Proper
temp

15
T oubleshooting
Diagnosis fo inve te models
Resumable
if lower than
100 degree
Flash times
fo emote type
Failu e code
on wi ed cont olle
Failu e code
fo cent al cont ol
Failu e desc iption
Reason
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Indoor ambient temp sensor failure
Indoor coil temp sensor failure
Outdoor ambient temp sensor failure
Outdoor coil temp sensor failure
Over-current protection
High pressure abnormal
Power supply abnormal
Communication between wired controller
and indoor abnormal
Communication between indoor and outdoor abnormal
Drainage system abnormal
Outside alarm signal input
Gas pipe temp sensor abnormal
Temperature protection malfunction
Discharging temp sensor abnormal
EEPROM abnormal
Pressure abnormal(low pressure)
Compressor overheat
Abnormal mode
Outdoor coil B(suction temp sensor-for MRV II)
Outdoor discharging B(oil temp sensor-for MRV II)
SPDU module temperature protection
Outdoor DC motor failure or system failure
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
CT check abnormal 3 times in 30m
High pressure switch acts 3 times in 30m
Fault phase, short of phase, out of balance greatly
Communication abnormal for more than 4m continuously
Communication abnormal for more than 4m continuously
Float switch broken down for more than 25m continuously
Outside signal broken down for more than 10s
Sensor broken down or short circuit for more than 2m continuously
Solenoid valve act incorrectly 3 times continuously
Sensor broken down or short circuit for more than 2m continuously
EEPROM data missing
Low pressure switch acts in normal running
The discharging temperature is higher than 120degree
Indoor operation mode is different with the running indoor unit
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
Spdu module temperature is too high
Outdoor DC motor abnormal or cooling & heating abnormal
Rema ks
01(01H)
02(02H)
74(4AH)
73(49H)
72(48H)
83(53H)
71(47H)
07(07H)
06(06H)
08(08H)
11(0BH)
03(03H)
13(0DH)
76(4CH)
05(05H)
84(54H)
80(50H)
12(0CH)
75(4BH)
77(4DH)
20(32D)
36(54D)
01D
02D
11D
12D
10D
14D
22D
06D
05D
21D
30D
20D
31D
15D
17D
26D
15D
23D
18D
15D
07D
08D
shows resumable fault,
shows it is not resumable fault

16
T ouble Shooting
Diagnosis fo On-Off models
Flash times
fo emote type
Failu e code
on wi ed cont olle
Failu e code
fo cent al cont ol
Failu e desc iption Reason
1
2
3
4
5
6
8
9
10
11
12
13
15
17
18
19
20
Indoor ambient temp sensor failure
Indoor coil temp sensor failure
Outdoor ambient temp sensor failure
Outdoor coil temp sensor failure/ Compressor
discharging temp sensor abnormal
Over-current protection / Power supply
abnormal
High/Low pressure abnormal
Communication between wired controller and
indoor abnormal
Communication between indoor and outdoor
abnormal
Drainage system abnormal
Outside alarm signal input
Gas pipe temp sensor abnormal
Temperature protection malfunction
EEPROM abnormal
Compressor overheat
Abnormal mode
Outdoor coil B(suction temp sensor-for MRV II)
Outdoor discharging B(oil temp sensor-for
MRV II)
Sensor broken down or short circuit for more than 2m
continuously
Sensor broken down or short circuit for more than 2m
continuously
Sensor broken down or short circuit for more than
2m continuously
Sensor broken down or short circuit for more than
2m continuously
CT check abnormal 3 times in 30m / Fault phase,
short of phase,out of balance greatly
High pressure switch acts 3 times in 30m/Low pressure
switch acts in normal running
Communication abnormal for more than 4m continuously
Communication abnormal for more than 4m continuously
Float switch broken down for more than 25m continuously
Outside signal broken down for more than 10s
Sensor broken down or short circuit for more than 2m
continuously
Solenoid valve act incorrectly 3 times continuously
EEPROM data missing
The discharging temperature is higher than 120degree
Indoor operation mode is different with the running
indoor unit
Sensor broken down or short circuit for more than 2m
continuously
Sensor broken down or short circuit for more than 2m
continuously
Remarks
01(01H)
02(02H)
74(4AH)
73(49H)
72(48H)
83(53H)
07(07H)
06(06H)
08(08H)
11(0BH)
03(03H)
13(0DH)
05(05H)
80(50H)
12(0CH)
75(4BH)
77(4DH)
01D
02D
11D
12D
10D
14D
06D
05D
21D
30D
20D
31D
17D
15D
23D
18D
15D
Resumable
if lower than
100 degree
shows resumable fault,
shows it is not resumable fault

(1) For the room air conditioner to operate satisfactorily, install it as outlined in this installation manual
(2) Connect the indoor unit and outdoor unit with the room air conditioner piping and cords available from our standard
parts This installation manual describes for the correct connections so that the installation set available from our
standard parts should be used
(3) Installation work must be performed in accordance with national wiring standards by authorized personnel only
(4) Never cut the power cord, lengthen or shorten the cord, or change the plug Do not use an extension cord
(5) Plug in the power cord plug firmly If the receptacle is loose, repair it before using the room air conditioner
(6) Do not turn on the power until all installation work is done
17
Installation P ocedu e Installation P ecaution
Please ask the dealer or specialist to install, never try by the users themselves After the installation please be sure of the
following conditions
Please call deale to install the ai -conditione . Inco ect installation may cause wate leaking, shock and fi e
haza d.
Ai -conditione can't be installed in the envi onment with inflammable gases because the inflammable gases
nea ai -conditione may cause fi e haza d.
Installed elect ical-leaking ci cuit b eake .
It easily cause electrical shock without circuit breaker
Connect ea thing wi e.
Earthing wire should not be connected to the gas pipe, water pipe, lightning rod or phone line, incorrect earthing
may cause shock
Use discha ge pipe co ectly to ensu e efficient discha ge.
Incorrect pipe use may cause water leaking
Wi ing
Air-conditioner should be equipped with special power supply wire
Location
Air-conditioner should be located in well-vented and easily accessible place
Air-conditioner should not be located in the following places:
(1) Places with machine oils or other oil vapours
(2) Seaside with high salt content in the air
(3) Near hot spring with high content of sulfide gases
(4) Area with frequent fluctuation of voltage e g factory, etc
(5) In vehicles or ships
(6) Kitchen with heavy oil vapour or humidity
(7) Near the machine emitting electric-magnetic waves
(8) Places with acid, alkali vapour
Choose the following locations:
(1) Capable of supporting air conditioner weight Don't increase operating noise and vibration
(2) Hot vapour from outdoor unit outlet and operating noise don't disturb neighbour
(3) No obstacles around the outdoor unit outlet
TV, radio, acoustic appliances etc are at least 1 m far away from the indoor unit, outdoor unit, power supply wire,
connecting wire, pipes, otherwise images may be disturbed or noises be created
As required, take measures against heavy snow
Ea thing
Fo autho ized sevice pe sonnel only
(1) Be careful not to scratch the room air conditioner when handing it
(2) After installation, explain correct operation to the customer, according to the operating manual
(3) Let the customer keep this installation manual because it will be used when the room air conditioner is serviced or moved
CAUTION
WARNING
CAUTION
WARNING

SELECTING THE MOUNTING POSITION
WARNING
CAUTION
Do not install the unit where there is the danger of combustible gas leakage
Do not install near heat sources
If children under 10 years old may approach the unit, take preventive measures so that they cannot reach the unit
Install at a place that can withstand the weight of the indoor unit and install it positively so that the unit will not topple or
fall
(1) Install the indoor unit level on a strong wall which is not subject to vibration
(2) The inlet and outlet ports should not be obstructed, and the air should be able to blow all over the room
(3) Do not install the unit where it will be exposed to direct sunlight
(4) Install the unit where connection to the outdoor unit is easy
(5) Install the unit where the drain pipe can be easily installed
(6) Take servicing, etc into consideration and leave the spaces shown in "Maintenace space dimension"
(7) Install the unit where the filter can be removed
ACCESSORIES FOR INSTALLATION
The following installation parts are optional parts Use them as required
18
Installation P ocedu e
Decide the mounting position with the custome as follows.
Fo half concealed installation
Ceiling
INDOOR UNIT
>3"(80mm) >6"(150mm) >0 4"(10mm)
Ceiling panel
INDOOR UNIT
>3"(80mm) >6"(150mm) >0 4"(10mm)
Ceiling panel
Fo ceiling installation
Optional parts
Adhesive tape
Saddle (L S) with screws
Drain hose
Heat insulation material
Piping hole cover
Putty
Plastic clamp
MAINTENANCE SPACE DIMENSION
This manual suits for next models
2
Table of contents
Other York Air Conditioner manuals

York
York SINGLE PACKAGE AIR CONDITIONER Guide

York
York SUPPLEMENTAL H4CE180A40 Owner's manual

York
York 12 SEER H*RC018 THRU 060 Quick start guide

York
York YDDN-22C(A/B)15A User manual

York
York JDOH Series User manual

York
York YJHMXH007BARR-FX User manual

York
York SUNLINE MagnaDRY DR 180 Instruction Manual

York
York SUNLINE MagnaDRY DR180C/E00 Quick start guide

York
York DY 048 Quick start guide

York
York STELLAR 2000 D3GH018 User manual