Zamel EXTA EDM-01 User manual

EDM - 01 SIGNALLING MODULE INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
FEATURES
TECHNICAL DATA
DESCRIPTION
APPERANCE
ی Applicable in signalling systems
,
ی Continuous duty acoustic module
,
ی Supplied directly from 230 V AC
network,
ی High sound level,
ی Single-module casing
,
ی Mounted on TH 35 rail
.
The EDM-01 signalling module may
be used in various systems, where
acoustic alarm is needed, e.g. as an
alarm signalling device. The module
is very flexible and applicable in
many circuits owing to the fact that
it is supplied directly from 230 V AC
network.
EDM - 01
Power terminals: L, N
Rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 15 mA
Load supply indicator: piezoelectric loudspeaker
Connection terminals quantity: 2
Connection wire section: 0,2 ÷ 2,50 mm2
Operating temperature: -20 ÷ +45 oC
Operating position: optional
Casing fastening: TH 35 rail (according to PN-EN 60715)
Casing IP: IP20 (PN-EN 60529)
Protection class: II
Overvoltage category: II
Pollution level: 2
Dimensions: single-module (17,5 mm) 90x17,5x66 mm
Weight: 51 g
Standard conformity: PN-EN 60669-1; PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
Piezoelectricloudspeaker
Power terminal (L)Power terminal (N)
The device should be
connected to a single-
phase system accordin-
gly to current standards.
The device connections
will be described in this
manual. Only qualied electricians are
allowed to mount, connect and adjust
the bell. It is necessary to read this ma-
nual before the device mounting. Do not
disassembly the timer casing or you will
lose any warranty rights and expose
yourself to the electric shock hazard.
Before mounting operation make sure
of disconnecting the connection wires
from the electric network. Use a cross-
head screwdriver of 3.5 mm diameter
to mount the device. The bell should
be carried, stored and used in an ap-
propriate way. Do not mount the bell in
case of any device parts lack, damage
or deformation. In case of malfunction
please notify the manufacturer.
CAUTION
ASSEMBLY, OPERATION
APPLICATIONCASING DIMENSIONS
PRODUCT FAMILY
The EDM-01 signalling module is a mem-
ber of the EDM family.
1. Disconnect the electric network
by means of an appropriate cut-
off, current-limiting circuit-brea-
ker or separator.
2. Check if there is no any vol-
tage between power leads by
means of an appropriate gau-
ge.
3. Mount the EDM-01 module on TH
- 35 rail.
4. Connect the system leads accor-
ding to the electrical diagram.
5. Connect power supply circuit.
The device is ready to work just
right after its appropriate connecting.
An internal piezoelectric loudspea-
ker is ON after the module supplying
with 230 V~ voltage. The speaker is
OFF when power supply is OFF.
CONNECTIONS TIME DIAGRAMS
UNIT DIAGRAM
Device version:
01 - continuous op
02 - resettable
03 - bell
Device type
EDM -
xx
L
N
L
N
The circuit warns against motor switch-OFF.
After the motor star by means of MOM-02
module, the PCM-01 counts preset time
(e.g. 10 s). During this period the EDM-01
module generates acoustic signal. When the
preset time is over, the sound will be OFF
and the motor starts.
PSU
WARRANTY
The product warranty is for a period of 24 months
Dealer signature & stamp, purchase date
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.

Other Zamel Control Unit manuals

Zamel exta EDM-02 User manual

Zamel

Zamel exta EDM-02 User manual

Zamel EXTA EDM-01 User manual

Zamel

Zamel EXTA EDM-01 User manual

Zamel exta EW-01 User manual

Zamel

Zamel exta EW-01 User manual

Zamel Exta LDM-11 User manual

Zamel

Zamel Exta LDM-11 User manual

Zamel Supla SBW-01 User manual

Zamel

Zamel Supla SBW-01 User manual

Zamel supla SRW-01 User manual

Zamel

Zamel supla SRW-01 User manual

Zamel RZB-03 User manual

Zamel

Zamel RZB-03 User manual

Zamel ROW-01 User manual

Zamel

Zamel ROW-01 User manual

Zamel ROW-01 User manual

Zamel

Zamel ROW-01 User manual

Popular Control Unit manuals by other brands

SMAR FY302 Operation, maintenance & instruction manual

SMAR

SMAR FY302 Operation, maintenance & instruction manual

RS S81 quick start guide

RS

RS S81 quick start guide

Sunfab 025-034 installation guide

Sunfab

Sunfab 025-034 installation guide

Aventics SV01 operating instructions

Aventics

Aventics SV01 operating instructions

Turbosmart RACE PORT Quick start quide

Turbosmart

Turbosmart RACE PORT Quick start quide

Agilent Technologies 83486A user guide

Agilent Technologies

Agilent Technologies 83486A user guide

Halemeier AppMitter installation instructions

Halemeier

Halemeier AppMitter installation instructions

Elvox 69AM/T4 Installation and operation manual

Elvox

Elvox 69AM/T4 Installation and operation manual

Altox GSM-4 GPS Operation manual

Altox

Altox GSM-4 GPS Operation manual

Pepperl+Fuchs ICE11-8IOL-G60L-V1D manual

Pepperl+Fuchs

Pepperl+Fuchs ICE11-8IOL-G60L-V1D manual

Hardy Instruments A Series Operation and installation manual

Hardy Instruments

Hardy Instruments A Series Operation and installation manual

SSS Siedle ELM 611-0 manual

SSS Siedle

SSS Siedle ELM 611-0 manual

KSB AMTRONIC R1300 User instructions

KSB

KSB AMTRONIC R1300 User instructions

Domestia DMC-012-003 S manual

Domestia

Domestia DMC-012-003 S manual

Aerotech Ensemble LAB Hardware manual

Aerotech

Aerotech Ensemble LAB Hardware manual

GEM 514 Assembly instructions

GEM

GEM 514 Assembly instructions

Genebre 2103 Installation, operation and maintenance manual

Genebre

Genebre 2103 Installation, operation and maintenance manual

Edwards TCU 40/80 instruction manual

Edwards

Edwards TCU 40/80 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.