Zamel ROW-01 User manual

1
ZAMEL ROW-01
FITTING INSTRUCTION MANUAL

2
Content
Technical data ......................................................................................................................................... 4
Installation remarks................................................................................................................................. 5
Mounting................................................................................................................................................. 5
Registry.................................................................................................................................................... 8
ROW-01 module configuration ............................................................................................................... 9
Installation and configuration of SUPLA on smartphones or tablets.................................................... 13

3
Welcome,
On behalf of the whole Zamel team, we would like to thank you for
choosing our product. Remember, this is an electronic device with mains power
supply, so keep in mind all safety rules during mounting. Make sure there is no
voltage on the connection cables by means of a special measuring equipment
before mounting. We did our best to make the product operates properly. But,
if you have any remarks regarding the device, its functionality, casing or
instruction, etc., we will implement your ideas and create a reliable product.
Feel free to contact us by means of an e-mail –we will certainly answer.
ZAMEL Team

4
Technical data
Nominal voltage supply:
230 VAC
Nominal frequency:
50 / 60 Hz
Nominal power consumption:
0,45 W
Transmission:
Wi-Fi
Operation range:
do 200 m in the open area
Number of external inputs:
2
Cooperation with switches:
monostable (push-buttons)
bistable (standard lighting switches without
backlight)
Number of output channels:
1
Relay contact parameters:
(voltage free NO contact)
1 x NO 5A / 250 VAC
Maximum output load:
1 x 5A / 250 V AC
incandescent and halogen lamps –750
W
CFL lamps –250
W
LED lamps–
60 W
Number of terminal clamps:
6 (cross-section of wires up to 2,5 mm2)
Casing mounting:
Ø60 mm junction box
Temperature operation range:
-10 do +55 °C
Casing protection degree:
IP20
Protection class:
II
Dimensions:
47,5 x 47,5 x 20 mm
Weight:
0,04 kg
Reference standard:
PN-EN 60669, PN-EN 60950, PN-EN 61000
PN-ETSI EN 300 220-1

5
Installation remarks
Do not mount the ROW-01 module in close proximity to each other (if possible, keep 15 cm
distance). Particularly avoid mounting one receiver over the another one. It can cause the
Wi-Fi connection disturbances.
It is important to obey maximum output loads:
• incandescent and halogen lamps: 750 W / channel
• CFL lamps: 250 W / channel
• LED lamps: 60 W / channel
During installation, pay attention the module is not exposed to a direct influence of water
and to operation in increased humidity. Ambient temperature in the mounting place should
be within the following range: -10 do +55°C.
ROW-01 module is designed to be installed indoor. During outdoor installation, it is
necessary to place the device in an additional hermetic casing.
Installation switches used in a wired control can be connected to IN1 and IN2 inputs of the
ROW-01 receiver. The inputs are designed to cooperate with monostable or bistable
switches. By default, the IN1 input operates in the monostable mode (doorbells), and the
IN2 input in the bistable mode (for standard lighting switches without backlight).
After installation, check proper operation of the receiver, and watch if the LED diode
switches on.
Mounting
ROW-01 module is designed to be used in flush mounting. The casing dimensions enable its
mounting in flush (minimum Ø60) and surface junction boxes. In case of flush mounting, the
use of deepened junction boxes is recommended.
The device is designed for a single-phase installation and must be installed in accordance
with standards valid in a particular country. Installation, connection and control should be
carried out by a qualified electrician staff, who act in accordance with the service manual
and the device functions. For safety reasons, do not mount the device without casing or with
a damaged one, as an electric shock may occur.
CAUTION! Before installation make sure the connection cables are not under voltage.

6
1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-
disconnector combined to the proper circuit. Remove the switch and disconnect the
wires.
2. Connect the device to power supply in accordance with one of the below presented
installing diagram, and switch on the power supply from the mains.
*) Diagram no. 1 –includes device mounting behind a bistable switch (standard lighting switch without
backlight)

7
*) Diagram no. 2 –includes device mounting behind a monostable switch (doorbell)

8
Registration
Starting the ROW-01 module requires an active user account at cloud.supla.org. If you do
not have an account yet, register now and follow the below presented steps. Registration
and system usage are free of charge.
Open https://cloud.supla.org website and click “Create an account”
*screenshot of https://cloud.supla.org screen –Logging
Fill in the form and click “Create an account”
* screenshot of https://cloud.supla.org screen –Registration

9
You will receive an e-mail with a link activating your user account. After activation, log in at
https://cloud.supla.org and enter data given in the registration form. After login, you have
an access to all necessary data required for configuration.
* screenshot of https://cloud.supla.org subpage “Start here”
If you already have a user account at cloud.supla.org server, you can enter the next step
regarding the connection and configuration of ROW-01 module.
Configuration ROW-01 module
After the device has been switched on, the software controls the settings. In case the
settings have not been implemented yet, the module switches automatically into the
configuration mode. It is signalled by means of a flashing LED diode. In other cases, press the
CONFIG push button for a longer time (available in a slot) for a minimum of 5 seconds to
enter the configuration mode. In this mode the module operates as a Wi-Fi access point and
is visible in the Wi-Fi network under the name of “ZAMEL-ROW-01”.

10
Establish a connection to the W-Fi “ZAMEL-ROW-01” (ROW-01 module must operate in the
configuration mode at that time) by means of any device (computer/tablet/smartphone)
that can be connected to Wi-Fi networks and has an installed browser. After a connection to
the W-Fi “ZAMEL-ROW-01” has been completed successfully, you can open the browser and
enter the following address: http://192.168.1 in the address bar.
After entering the address, the configuration website opens where you need to enter the WiFi
access settings through the module accesses the Internet (Fields marked in red).

11
* screenshot of http://192.168.4.1 - configuration website of ZAMEL ROW-01 module
Next, complete access data for SUPLA server (Supla settings). All necessary data are available
in the yellow form “supla-dev”, which is displayed after logging in at https://cloud.supla.org.
Rewrite data from the yellow field into the red ones. It means rewrite “Server address” into
“Server” field, “Location ID” into “Location ID” and “Password” into “Location Password”.
Network name
–Enter your Wi-
Fi
network n
ame (case sensitive).
Password
–Password to Wi-
Fi
network. It is visible while
entering. The field remains empty
after saving.

12
Click “Save” after you have finished entering all above mentioned settings. “DATA SAVED”
message is displayed to signal correct saving of settings. At that moment, restart the module
again by pressing the red CONFIG push-button (available in the slot) or just disconnect and
connect the device.
The module establishes a Wi-Fi connection. It is signalled by a flashing LED (2 flashes/1
second). In case of a positive connection, the device establishes a connection with SUPLA
server. It is signalled by a flashing LED (1 flash/1 second). The LED remains on, if the
connection with the server has been successful (or it switches off according to the
configuration setting: the LED switches off after successful connection).
After a successful server connection, the module is ready to operate and you can start
configuration of the application on a smartphone or a tablet.

13
Installation and configuration SUPLA App on
smartphones or tablets
In case of smartphones/tablets with Android system operation, open Google Play store, next
find the SUPLA application and install it.
In case of iPhone or iPad, open AppStore, next find the SUPLA application and install it.

14
After installation and activation of the application, settings are automatically displayed. It is
required to fill in the access data for SUPLA server. You can find all necessary data in the
green form “supla-client”, which is displayed after login in at https://cloud.supla.org.
Rewrite data from the green form into the red fields.
After entering all settings correctly, the application connects with the server and enables
switching on / switching off the lighting / power supply by means of the ZAMEL ROW-01
module from any place in the world with the Internet access.
Other manuals for ROW-01
2
Table of contents
Other Zamel Control Unit manuals
Popular Control Unit manuals by other brands

inveo
inveo Nano Relay Output PoE user manual

Honeywell
Honeywell D05FS installation instructions

Leb Electronics
Leb Electronics CTR64 instruction manual

Agilent Technologies
Agilent Technologies 83400 Series user guide

Flowserve
Flowserve Argus EK Series Installation, commissioning maintenance

Bosch