manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zamel
  6. •
  7. Control Unit
  8. •
  9. Zamel exta EDM-02 User manual

Zamel exta EDM-02 User manual

EDM - 02 SIGNALLING MODULE INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
FEATURES
TECHNICAL DATA
DESCRIPTION
APPERANCE
ی Applicable in signalling and con-
trol systems,
ی Acoustic module,
ی Reset button,
ی LED indicator built in a reset but-
ton,
ی Relay voltage output, NO / NC,
ی Single-module casing,
ی Mounted on TH 35 rail.
The EDM-02 signalling module may be
used in various systems, where acous-
tic alarm is needed. The module is fitted
with a button for acoustic signal reset
and switching OFF a relay. There is a
LED placed inside a push button for
power supply indicating.
EDM - 02
Power terminals: L, N
Rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 31 mA
Relay switch-ON control: piezoelectric loudspeaker
Relay contacts parameters: 16 A NO/NC 4000 VA AC1
Connection terminals quantity: 5
Connection wire section: 0,2 ÷ 2,50 mm2
Operating temperature: -20 ÷ +45 oC
Operating position: optional
Casing fastening: TH 35 rail (according to PN-EN 60715)
Casing IP: IP20 (PN-EN 60529)
Protection class: II
Overvoltage category: II
Pollution level: 2
Dimensions: single-module (17,5 mm) 90x17,5x66 mm
Weight: 70 g
Standard conformity: PN-EN 60669-1; PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
Control key
Piezoelectricloudspeaker
Power supply signalling
Power lead (L)Power lead (N)
The device should be
connected to a single-
phase system accordin-
gly to current standards.
The device connections
will be described in this
manual. Only qualied electricians are
allowed to mount, connect and adjust
the bell. It is necessary to read this ma-
nual before the device mounting. Do not
disassembly the timer casing or you will
lose any warranty rights and expose
yourself to the electric shock hazard.
Before mounting operation make sure
of disconnecting the connection wires
from the electric network. Use a cross-
head screwdriver of 3.5 mm diameter
to mount the device. The bell should
be carried, stored and used in an ap-
propriate way. Do not mount the bell in
case of any device parts lack, damage
or deformation. In case of malfunction
please notify the manufacturer.
CAUTION
APPLICATION
ASSEMBLY, OPERATION
CASING DIMENSIONS
PRODUCT FAMILY
The EDM-02 signalling module is a mem-
ber of the EDM family.
1. Disconnect the electric network by
means of an appropriate cut-off, cur-
rent-limiting circuit-breaker or sepa-
rator.
2. Check if there is no any voltage be-
tween power leads by means of an
appropriate gauge.
3. Mount the EDM-02 module on TH 35
rail.
4. Connect the system leads according to
the electrical diagram.
5. Connect power supply circuit.
The module is ready to work just right
after its appropriate connecting. An aco-
ustic signalling and a relay are ON after
the module supplying. This state is mai-
ntained until the control key is pressed.
Then the acoustic signal and relay will
be OFF. Successive key pressing will not
affect the module state. Operating cycle
will be repeated after power supply cut-
off and turning it again. An internal button
LED indicates power supply ON.
CONNECTIONS TIME DIAGRAMS
LOAD
UNIT DIAGRAM
L
N
The voltage drop detection circuit. The EDM-02 module signals acoustically voltage
drop and return. The module reset is possible by means of the reset button pressing.
The relay operates the same way as the bell. Additionally, the relay contacts are con-
nected with the voltage drop signalling circuit including a battery and a light bulb.
L
N
Device version:
01 - continuous op
02 - resettable
03 - bell
Device type
EDM -
xx
WARRANTY
The product warranty is for a period of 24 months
Dealer signature & stamp, purchase date
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.

Other Zamel Control Unit manuals

Zamel ROW-01 User manual

Zamel

Zamel ROW-01 User manual

Zamel RZB-03 User manual

Zamel

Zamel RZB-03 User manual

Zamel Supla SBW-01 User manual

Zamel

Zamel Supla SBW-01 User manual

Zamel EXTA EDM-01 User manual

Zamel

Zamel EXTA EDM-01 User manual

Zamel ROW-01 User manual

Zamel

Zamel ROW-01 User manual

Zamel exta EW-01 User manual

Zamel

Zamel exta EW-01 User manual

Zamel Exta LDM-11 User manual

Zamel

Zamel Exta LDM-11 User manual

Zamel supla SRW-01 User manual

Zamel

Zamel supla SRW-01 User manual

Zamel EXTA EDM-01 User manual

Zamel

Zamel EXTA EDM-01 User manual

Popular Control Unit manuals by other brands

Leviton RENOIR II Series Installation

Leviton

Leviton RENOIR II Series Installation

Festo CPX-CM-HPP Description

Festo

Festo CPX-CM-HPP Description

ViewSonic VPC14-WP quick start guide

ViewSonic

ViewSonic VPC14-WP quick start guide

SolarEdge ZigBee Plug-in installation guide

SolarEdge

SolarEdge ZigBee Plug-in installation guide

ADTRAN TRACER QUAD E1 quick start guide

ADTRAN

ADTRAN TRACER QUAD E1 quick start guide

FISNAR VD510-UV instruction manual

FISNAR

FISNAR VD510-UV instruction manual

Time Electronics 7085A user manual

Time Electronics

Time Electronics 7085A user manual

Bender ATICS UMA710-2-63-ISO manual

Bender

Bender ATICS UMA710-2-63-ISO manual

Exsys EX-1303 user manual

Exsys

Exsys EX-1303 user manual

VAT 570 Series Installation, operating,  & maintenance instructions

VAT

VAT 570 Series Installation, operating, & maintenance instructions

Bticino 375000 quick start guide

Bticino

Bticino 375000 quick start guide

M-system R5-NE1 instruction manual

M-system

M-system R5-NE1 instruction manual

Huawei MU709s-2 Hardware guide

Huawei

Huawei MU709s-2 Hardware guide

Straval PRS-09i THD operating instructions

Straval

Straval PRS-09i THD operating instructions

KSB ECOLINE GT 40 operating manual

KSB

KSB ECOLINE GT 40 operating manual

ELCODIS 710-0004-01 manual

ELCODIS

ELCODIS 710-0004-01 manual

Tellur TLL331501 installation guide

Tellur

Tellur TLL331501 installation guide

Studer Xcom-SMS user manual

Studer

Studer Xcom-SMS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.