manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zamel
  6. •
  7. Measuring Instrument
  8. •
  9. Zamel exta LEM-04 User manual

Zamel exta LEM-04 User manual

Other Zamel Measuring Instrument manuals

Zamel EXTA LDM-10 User manual

Zamel

Zamel EXTA LDM-10 User manual

Zamel LKM - 01 User manual

Zamel

Zamel LKM - 01 User manual

Zamel exta LEM-40 User manual

Zamel

Zamel exta LEM-40 User manual

Zamel exta LKM-02 User manual

Zamel

Zamel exta LKM-02 User manual

Zamel LKM-03 User manual

Zamel

Zamel LKM-03 User manual

Zamel LEM-30 User manual

Zamel

Zamel LEM-30 User manual

Zamel Exta LKM-03 User manual

Zamel

Zamel Exta LKM-03 User manual

Zamel LKM - 01 User manual

Zamel

Zamel LKM - 01 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ELECTRICITY METER LEM-04
DIGITAL - SINGLE-PHASE USER’S MANUAL
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.com, e-mail: [email protected]
lem-04_inst_ext_gb | 10.02.21
FEATURES
TECHNICAL DATA
DESCRIPTION
APPEARANCE
LEM-04
Power supply terminals: line L: 1 (LIN), 3 (LOUT); line N: 4, 6
Reference voltage: 230 V AC
Voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Base / maximum current: 5 A / 45 A
Minimum current: 0,4% of base current (25 mA)
Meter own consumption: 10 VA / 2 W
Accuracy of measurement (IEC61036): class B
Display: counter 5+2 digits
Indication for pulse counting: red LED
Pulse output SO+ SO-: type OC: 20(+), 21(-)
Connection voltage SO+ SO-: 5 ÷ 27 V DC
SO+ SO- connection current: < 27 mA
SO+ SO- constant: 2000 pulses per kWh
Pulse time SO+ SO-: 90 ms
Number of connection terminals: 6
Cross-section of connection cables: 0,2 ÷ 6 mm2
Operating temperature: -10 ÷ +50 oC
Enclosure mounting: TH 35 rail (according to EN 60715)
Enclosure IP rating: IP51 (PN-EN 60529)
Overvoltage category: II
Contamination degree: 2
Dimensions: single-module enclosure
Weight: 0,100 kg
Compliance with standards: PN-EN 62094-1; PN-EN 61000-4-2,3,4,5,6,11
● Opticalindicationforpulsecounting,
● LCDdisplay,
● additionalpulseoutput,
● sealableterminalcovers,
● single-modulehousing,
● InstallationonTH35rail.
LEM-04 device is a single-phase
electricity meter, which can be used as
a electricity sub-meter for single-phase
AC circuit. Measurement of electricity
consumption is signalled by LED and its
value is indicated on LCD. The meter is
also equipped with pulse output allowing
connecting an additional counting device.
To protect the device against the illegal
power consumption LEM-04 is protected
with plastic enclosures on the terminals,
which can be sealed.
The device should be con-
nected to a one-phase network
in accordance with legally bind-
ing standards. The connection
method is described in this
manual. Any activities related
to installation, connection, and adjustment
shouldbeperformedbyqualiedelectricians
who have read this user’s manual and famil-
iarised themselves with device functions. Re-
moving the enclosure voids the warranty and
poses a risk of electric shock. Before instal-
lation, make sure that there is no voltage on
connection cables. To install the device, use
a cross-head screwdriver with a diameter of
3.5 mm. The proper operation of the device
is affected by how the device is transported,
stored, and used. It is not advisable to install
the device in the following cases: lack of any
components, damage to or deformation of
the device. If the device operates improperly,
please contact the manufacturer.
NOTE
Do not dispose of this device together
with other waste! To avoid harmful effects
on the environment and human health,
the worn-out device should be stored
in designated areas. Electrical waste
from households may be handed over
to the waste collector established for
this purpose free of change and in any
amount, as well as to the store when
purchasing new equipment.
Terminal covers
Input LIN (1)
Output LOUT (3)
Indication for pulse counting
LCD display
Pulse output + (20), - (21)
Output N (6)
Input N (4)
V
ASSEMBLY, OPERATION
1. Disconnect the safety power supply
circuit, the overcurrent circuit breaker
or the isolating switch connected to the
corresponding water circuit.
2. Check voltage-free condition on the
supply cables with proper instru-
ment.
3. Install LEM-04 in the switchboard on
TH 35 (DIN) rail.
4. Connect the wires to the terminals in
accordance with the wiring diagram.
5. Switch on the power supply.
Current owing throught the device
causes that generated pulses are propor-
tional to amount of drawn electric energy
(2000pulsesperkWh).AashingLEDin-
dicates current consumption and the fact
that the device is measuring. The value
can be read from segment LCD. The
digits after the decimal point indicate the
hundredths of 0.01 kWh (10 Wh).
NOTES:
• When using pulse input (terminals
20, 21) it is necessary to apply addi-
tional supply voltage within a range
5 ÷ 27 V DC.
• It is recommended to use an addi-
tional resistor R (470 Ω ÷ 1 kΩ) to
limit the value of current.
• Changing the power supply polarity
may damage the indicator’s pulse
output.
• If there is no connection then the
metering device should not be con-
nected to pulse output of the supply
system.
CONNECTION
INTERNAL DIAGRAM
LEM-04 device used as an additional electricity meter in a house inhabited by two
families
WARRANTY CARD
Manufacturer provides a 24-month warranty
Seller’s stamp and signature, date of sale
1. ZAMEL Sp. z o.o. shall offer a 24-month warranty on the products sold.
2. The warranty provided by ZAMEL Sp. z o.o. shall not cover:
a) mechanical damage caused during transport, loading/unloading or in other circumstances,
b) damage caused by incorrect installation or operation of products manufactured by ZAMEL Sp. z o.o.,
c) damage resulting from any changes made by the BUYER or third parties in the products sold or equipment necessary for the
proper operation of the products sold,
d) damage resulting from force majeure or other fortuitous events for which ZAMEL Sp. z o.o. is not liable.
3. Any warranty claims shall be made by the BUYER at the point of sale or to ZAMEL z o.o. in writing after defects have been identi-
ed.
4. ZAMEL Sp. z o.o. undertakes to handle complaints in accordance with the applicable provisions of Polish law.
5. The choice of the form of complain resolution, e.g. replacement of a product with a product free from defects, repair, or reimburse-
ment of money, shall lie with ZAMEL Sp. z o.o.
6. The warranty does not exclude, limit, or suspend BUYER’s rights under the statutory warranty for defects in the item sold.
MEASURED
CIRCUIT
ADDITIONAL
COUNTING
DEVICE
R
(470Ω÷1kΩ)
5 ÷ 27 V DC
PRIMARY
METER
ELECTRICAL
INSTALLATION
GROUND
FLOOR
ELECTRICAL
INSTALLATION
FLOOR
LOUT
LIN
4
20
21
1
6
3
N