manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zamel
  6. •
  7. Measuring Instrument
  8. •
  9. Zamel exta LEM-40 User manual

Zamel exta LEM-40 User manual

Other Zamel Measuring Instrument manuals

Zamel LKM - 01 User manual

Zamel

Zamel LKM - 01 User manual

Zamel EXTA LDM-10 User manual

Zamel

Zamel EXTA LDM-10 User manual

Zamel exta LEM-04 User manual

Zamel

Zamel exta LEM-04 User manual

Zamel LKM-03 User manual

Zamel

Zamel LKM-03 User manual

Zamel exta LKM-02 User manual

Zamel

Zamel exta LKM-02 User manual

Zamel Exta LKM-03 User manual

Zamel

Zamel Exta LKM-03 User manual

Zamel LKM - 01 User manual

Zamel

Zamel LKM - 01 User manual

Zamel LEM-30 User manual

Zamel

Zamel LEM-30 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ELECTRICITY METER LEM-40
DIGITAL - THREE-PHASE USER’S MANUAL
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamel.com, e-mail: [email protected]
lem-40_inst_ext_gb | 10.02.21
FEATURES
TECHNICAL DATA
DESCRIPTION
APPEARANCE
Power supply terminals: top - inputs (IN): L1, L2, L3, N
bottom - outputs (OUT): L1, L2, L3, N
Reference voltage: 3 x 230 V / 400 V AC
Voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Base current (Ib): 3 x 10 A
Maximum current (Imax): 100 A
Operating current range: 0,4% Ib÷ Imax
Current overload: 30x Imax for 0,01 s
Meter own consumption: 10 VA / 2 W
Accuracy of measurement (IEC61036): class B (class 1)
Display: Counter 6+2 digits
Indication for pulse counting: red LED
Pulse output SO+ SO-: OC type, terminals: 22 (-), 23 (+)
Connection voltage SO+ SO-: 5 ÷ 27 V DC
SO+ SO- connection current: < 27 mA
SO+ SO- contant: 1000 pulses per kWh
Pulse time SO+ SO-: 30 ms
Number of connection terminals: 10
Cross-section of connection cables: main connection: 4 ÷ 25 mm2
pulse output: minimum 0.2 mm2
Operating temperature: -25 ÷ +55 oC
Enclosure mounting: TH 35 rail (according to EN 60715)
Enclosure IP rating: IP51
Overvoltage category: II
Contamination degree: 2
Dimensions: 72 x 100 x 66 mm
Weight: 0,700 kg
● Three-phasedigitalenergymeter,
● ClassB(equivalenttoclass1),
● Maximumcurrentofthemeter:100A,
● 6+2LCDdisplay,
● Additionalpulseoutput,
● Indicationforpulsecounting,
● Signalling the presence of voltage of each
phase,
● Sealableterminalcovers,
● InstallationonTH35rail.
The LEM-40 digital, three-phase electricity
meter is a precision device measuring the pow-
er consumption in a three-phase system. The
meter operates in class B (equivalent to class
1). The device is equipped with a legible LCD
and signaling diodes informing about the pres-
ence of voltage of a given phase. ZAMEL LEM-
40 meter is used to monitor power consumption
of three-phase system in consumer, commer-
cial and industrial applications. The product is
ideal solution for billing the power consumption
in garages, workshops, plots of land, tenants of
facilities or for machinery control. The device
measures and displays electricity expressed in
kWh rounded to 2 decimal places (0.01kWh).
W results are presented on a 6+2 digital display.
Pulse output of the meter allows connecting
metering device and presenting the measure-
ment results on the additional display/system.
The meter can be easily installed in electric
cabinets because it has compact 4-module de-
sign (4 DIN modules). The device is equipped
withsafetyaps,whichcanbesealed.
The device should be connected
to a three-phase network in ac-
cordance with legally binding
standards. The connection meth-
od is described in this manual.
Any activities related to instal-
lation, connection, and adjustment should be
performed by qualied electricians who have
read this user’s manual and familiarised them-
selves with device functions. Removing the
enclosure voids the warranty and poses a risk
of electric shock. Before installation, make sure
that there is no voltage on connection cables.
To install the device, use a cross-head screw-
driver with a diameter of 3.5 mm. The proper
operation of the device is affected by how the
device is transported, stored, and used. It is not
advisable to install the device in the following
cases: lack of any components, damage to or
deformation of the device. If the device oper-
ates improperly, please contact the manufac-
turer.
NOTE
Do not dispose of this device together with other
waste! To avoid harmful effects on the environment and
human health, the worn-out device should be stored
in designated areas. Electrical waste from households
may be handed over to the waste collector established
for this purpose free of change and in any amount, as well as to
the store when purchasing new equipment.
LCD display
Input terminals
L1, L2, L3, N
Indication
for pulse counting
Pulse
output
Output terminals
L1, L2, L3, N
Voltage
presence indication
INTENDED USE
ASSEMBLY, OPERATION
1. Before assembly you should familiarize
yourself with the manual and observe the
requirements related to location and con-
ditions of assembly. The assembly should
be carried out by a person with appropriate
authorizations.
2. All assembly works should be carried
out after disconnection of supply voltage
(measuring voltage).
3. Use only insulated tools.
4. The cables used should conduct the maxi-
mum current assumed for the given meter.
5. Check voltage-free condition on supply
conductors using a proper measuring in-
strument.
6. Install the device in the switchboard on the
TH35 rail.
7. Connect the wires to the terminals in ac-
cordance with the wiring diagram.
8. Switch on the power supply.
9. Do not touch connecting terminals of the
meter with bare hands, metal objects, non-
insulated wire or other conductive object,
because it poses a risk of electric shock,
which can result in injuries, serious injuries
or death.
10. Maintenance and repairs of the meter can
becarriedout only byqualiedpersonnel
with valid authorizations.
11. The meter should be protected against fall
and mechanical impacts, that may cause
damage of precise components inside it
and have adverse effect on accuracy of the
measurements.
NOTE: Using pulse output (terminals 22
and 23) you should apply additional sup-
ply voltage within the range 5 ÷ 27 V DC
through a resistor R (470 Ω ÷ 1 kΩ) limiting
the value of the current.
CONNECTION
PRODUCT SERIES
The LEM-40 energy meter belongs to the LEM
series of meters.
Device version:
02 - single-phase, digital
02LM - single-phase, digital,
MID
04 - single-phase, digital
30 - three-phase, digital
30M - three-phase, digital
MID
40 - three-phase, digital
Device symbol
LEM-XX
WARRANTY CARD
Manufacturer provides a 24-month warranty
Seller’s stamp and signature, date of sale
1. ZAMEL Sp. z o.o. shall offer a 24-month warranty on the products sold.
2. The warranty provided by ZAMEL Sp. z o.o. shall not cover:
a) mechanical damage caused during transport, loading/unloading or in other circumstances,
b) damage caused by incorrect installation or operation of products manufactured by ZAMEL Sp. z o.o.,
c) damage resulting from any changes made by the BUYER or third parties in the products sold or equipment necessary for the
proper operation of the products sold,
d) damage resulting from force majeure or other fortuitous events for which ZAMEL Sp. z o.o. is not liable.
3. Any warranty claims shall be made by the BUYER at the point of sale or to ZAMEL z o.o. in writing after defects have been identi-
ed.
4. ZAMEL Sp. z o.o. undertakes to handle complaints in accordance with the applicable provisions of Polish law.
5. The choice of the form of complain resolution, e.g. replacement of a product with a product free from defects, repair, or reimburse-
ment of money, shall lie with ZAMEL Sp. z o.o.
6. The warranty does not exclude, limit, or suspend BUYER’s rights under the statutory warranty for defects in the item sold.
MEASURED
CIRCUIT
ADDITIONAL
COUNTING
DEVICE
R(470Ω÷1kΩ)
5 ÷ 27 V DC
L1
L2
L3
N
ELECTRICAL
INSTALLATION
HOME
L1
L2
L3
N
PRIMARY
METER
ELECTRICAL
INSTALLATION
WORKSHOP
LEM-40 device used as an additional
electricity meter in the workshop.