6 - EN
2 Installation conditions
■Always install the equipment according to the
latest regulations for installation of your country.
■Install the unit on a 230V~ 50Hz mains connection.
Any other power connection will damage the unit.
■The unit is designed for residential use. The unit
is not made for industrial use, such as swimming
pools or saunas. Installation in an industrial
environment can damage the unit.
■Check if the installation area will remain in the
permitted temperature range throughout the year.
You can find the permitted temperature range in
the chapter “Technical specifications”.
■It is recommended not to install the unit in areas
with a higher than average humidity (such as
bathroom or w.c.). This will prevent condensation
on the outside of the unit.
■Check if the temperature of the moved air will
remain in the permitted temperature range
throughout the year. You can find the permitted
temperature of the moved air in the chapter
“Technical specifications”.
■Check if the electrical installation is suitable for
the maximum power of the unit. You can find the
maximum power values in the chapter “Technical
specifications”.
■Check if the electrical installation is suitable
for the maximum power of the desired
optional ancillaries. You can find the technical
specifications of the desired optional ancillaries in
their associated manuals.
■Check if the installation area of the unit has
sufficient room for the following:
- The unit (no additional room needed on the side)
- Carrying out maintenance activities in front of
the unit (at least 1m);
- The condensation drain below the unit (optional);
- The air duct system including sound attenuators;
- The wiring for an external wired controller
(optional);
- The desired optional ancillaries and when
needed its easily accessible electrical power
connection;
- The easily accessible electrical power
connection of the unit. You can find the length
of the power cable in the chapter “Technical
specifications”.
■Within a distance of 1 metre or at most the length
of the fixed (or supplied) power cable (both 3-core
and 5-core), an earthed wall outlet must be
available.
■Always use the fixed (or supplied) power cable
(both 3-core and 5-core).
■For safety reasons, do not use an extension cable.
3 Transport and unpacking
You can find the permitted transport and
storage temperature in the chapter “Technical
specifications”.
Transport and unpack the unit with care. Discard
the packing material in an environmentally friendly
manner.
Checking the delivery
Speak to your supplier immediately in case of
damage or an incomplete delivery. The delivery
should at least include:
Appearance example Name
The unit
Check the identification plate to
ensure that it is the correct type
Mounting bracket
Condensation drain set
Unit with standard heat exchanger:
■Condensation drain adapter 32mm
pipe;
■Condensation drain adapter 1¼”
thread pipe;
■Condensation drain sealing cap.
Unit with enthalpy exchanger:
■2 condensation drain sealing caps.
Power cord
Documentation
Dust cover
Only remove the dust cover
just before you install the air
ducts.
Information found on the identification plate
Suffix Meaning
ComfoAir Product family name.
QProducttypename.
350 Maximum air volume of 350 m3/h.
450 Maximum air volume of 450 m3/h.
600 Maximum air volume of 600 m3/h.
GB Country code of the unit.
R The unit has been set with the supply and extract air
on the right side as default.
L The unit has been set with the supply and extract air
on the left side as default.
ST The unit has four fixed air connections.
PH The unit has a pre-heater installed as default.
ERV The unit has an enthalpy exchanger installed as
default.