2N Access Unit User manual

www.2n.cz
2N Access Unit
®
Access Control
Installation manual
Firmware:
Version: 2.11

The 2N TELEKOMUNIKACE a.s. is a Czech manufacturer and supplier of
telecommunications equipment.
The product family developed by 2N TELEKOMUNIKACE a.s. includes GSM gateways,
private branch exchanges (PBX), and door and lift communicators. 2N
TELEKOMUNIKACE a.s. has been ranked among the Czech top companies for years
and represented a symbol of stability and prosperity on the telecommunications
market for almost two decades. At present, we export our products into over 120
countries worldwide and have exclusive distributors on all continents.
2N is a registered trademark of 2N TELEKOMUNIKACE a.s. Any product and/or other
®
names mentioned herein are registered trademarks and/or trademarks or brands
protected by law.
2N TELEKOMUNIKACE a.s. administers the FAQ database to help you quickly find
information and to answer your questions about 2N products and services. On www.
faq.2n.cz you can find information regarding products adjustment and instructions for
optimum use and procedures „What to do if...".
2N TELEKOMUNIKACE a.s. hereby declares that the 2N product complies with all
®
basic requirements and other relevant provisions of the 1999/5/EC directive. For the
full wording of the Declaration of Conformity see the CD-ROM (if enclosed) or our
website at www.2n.cz.
The 2N TELEKOMUNIKACE a.s. is the holder of the ISO 9001:2009 certificate. All
development, production and distribution processes of the company are managed by
this standard and guarantee a high quality, technical level and professional aspect of
all our products.

2N TELEKOMUNIKACE a.s., www.2n.cz 3/98
Content:
1. Product Overview
1.1 Components and Associated Products
1.2 Terms and Symbols
2. Description and Installation
2.1 Before You Start
2.2 Mechanical Installation
2.2.1 One Module Box
2.2.2 Two Module Box
2.2.3 Module dimensions
2.3 Electric Installation
2.4 Extending Module Connection
2.5 Mounting Completion
3. Maintenance
4. Technical Parameters
5. Supplementary Information
5.1 Troubleshooting
5.2 Directives, Laws and Regulations
5.3 General Instructions and Cautions

2N TELEKOMUNIKACE a.s., www.2n.cz 4/98
1. Product Overview
Here is what you can find in this section:
1.1 Components and Associated Products
1.2 Terms and Symbols

2N TELEKOMUNIKACE a.s., www.2n.cz 5/98
Basic Properties
2N Access Unit
® is an elegant and reliable access IP system equipped with a number
of useful functions, which are not always common in devices of this category.
2N Access Unit
®is a modular access system that meets all individual user needs.
Unlike other access systems available on the market, is not a single-2N Access Unit
®
module system with a fixed functionality, but a user friendly modular system, allowing
the user to assemble required modules and accessories on a “plug and play” basis.
This approach provides individual configuration options and increase in functionality
as necessary.
Keypad is a numeric keypad module that allows you to use the device for code lock
switch activation.
Integrated card reader module provides the RFID card access control functionality.
With additional software settings, you can control more functions than the door lock
using the card.
Electric lock switch – this switch can be can be controlled via a numeric keypad or
Automation actions. The switch can be completed with additional output modules if
necessary. A wide range of the switch mode settings provide an infinite number of
applications.
Resistance – is designed as a robust, mechanically resistant access 2N Access Unit
®
system, which withstands any weather conditions without requiring additional
accessories.
Installation of is very easy. All you have to do is assemble the 2N Access Unit
®
required modules and connect the system to your LAN via a mains cable. Being of the
“plug and play” type, the modules need not be configured individually. Feed the
intercom either from a 12 V power supply or directly from your PoE-supporting LAN.
To configure 2N Access Unit
®, you need a PC equipped with any Internet browser. To
manage extensive intercom installations easily, use the .2N Access Commander
®

2N TELEKOMUNIKACE a.s., www.2n.cz 6/98
Advantages of Use
Elegant design
Weather resistance
Variable mounting options (brick/plasterboard flush mounting, wall mounting)
Optional numeric keypad with backlight
Use of multiple modules of the same type – e.g. building entrance/exit card
reader
Integrated electronic lock switches with wide setting options
Integrated RFID card reader module or Bluetooth module
LAN (PoE) or external 12 V power supply
Configuration via web interface
HTTP server for configuration
SNTP client for server time synchronisation
SMTP client for e-mail sending
TFTP/HTTP client for automatic configuration and firmware update

2N TELEKOMUNIKACE a.s., www.2n.cz 7/98
1.1 Components and Associated Products
Basic Units
Part No. 916009
2N Access Unit 125 kHz
®
Part No. 916010
13.56 MHz + NFC2N Access Unit
®
Part No. 916013
2N Access Unit Bluetooth
®

2N TELEKOMUNIKACE a.s., www.2n.cz 8/98
Part No. 916019
2N Access Unit Fingerprint reader
®
Tip
Supported auxiliary modules: 2N Helios IP Verso modules are
®
– RFID card reader (125 kHz; 13.56 MHz), keypad, 5-button supported
module, Wiegand, etc.

2N TELEKOMUNIKACE a.s., www.2n.cz 9/98
Frames
9155011 Part No. Flush mounting frame, 1-module
Covering frame for the 1-module brick/plasterboard
flush mounting box. This 1-module frame is used for
connection of an OUT card reader or keypad, for
example. Remember to order the frame when you order
a 1-module flush mounting box, Part No. 9155014.
9155011BPart No. Flush mounting frame, 1-module
Covering frame for the 1-module brick/plasterboard
flush mounting box. This 1-module frame is used for
connection of an OUT card reader or keypad, for
example. Remember to order the frame when you order
a 1-module flush mounting box, Part No. 9155014.
9155012 Part No. Flush mounting frame, 2-module
Covering frame for the 2-module brick/plasterboard
flush mounting box. Remember to order the frame when
you order a 2-module flush mounting box, Part No.
9155015.

2N TELEKOMUNIKACE a.s., www.2n.cz 10/98
9155012BPart No. Flush mounting frame, 2-module
Covering frame for the 2-module brick/plasterboard
flush mounting box. Remember to order the frame when
you order a 2-module flush mounting box, Part No.
9155015.
9155021 Part No. Wall mounting frame, 1-module
Covering frame for wall (surface) mounting.This 1-
module frame is used for connection of an OUT card
reader or keypad, for example.
9155021BPart No. Wall mounting frame, 1-module
Covering frame for wall (surface) mounting.This 1-
module frame is used for connection of an OUT card
reader or keypad, for example.

2N TELEKOMUNIKACE a.s., www.2n.cz 11/98
9155022 Part No. Wall mounting frame, 2-module
Covering frame for wall (surface) mounting.
9155022BPart No. Wall mounting frame, 2-module
Covering frame for wall (surface) mounting.
Tip
The 1-module frame is used when an auxiliary module from 2N Helios
®
is mounted onto an extended interconnecting cable, for an OUT IP Verso
card reader or keypad, for example.

2N TELEKOMUNIKACE a.s., www.2n.cz 12/98
Tip
Remember to order the flush mounting frame when you order a brick
/plasterboard flush mounting box:
1-module frame, Part No. – 1-module flush mounting box, 9155011
Part No. .9155014
2-module frame, Part No. – 2-module flush mounting box, 9155012
Part No. .9155015

2N TELEKOMUNIKACE a.s., www.2n.cz 13/98
Extending Modules
Part No. 916020 RJ-45 adapter
Part No. 9155033
2N Helios IP Verso
®– 13.56 MHz RFID Card Reader
The card reader module works with
2N Access Unit
® as an OUT card reader. The module supports cards,
key fobs and/or other 13.56 MHz standard carriers (only card serial
number is read):
ISO/IEC 14443A Mifare Classic 1k & 4k, DESFire EV1, Mini, Plus
S&X, Ultralight, Ultralight C
ISO/IEC 14443B CEPAS, HID iCLASS
JIS X 6319 Felica
Part No. 9155040
Helios IP Verso 2N® – 13.56 MHz RFID Card Reader, NFC Preparation
The card reader module works with as an OUT card 2N Access Unit
®
reader. The module supports cards, key fobs and/or other 13.56 MHz
standard carriers (only card serial number is read):
ISO/IEC 14443A Mifare Classic 1k & 4k, DESFire EV1, Mini, Plus
S&X, Ultralight, Ultralight C
ISO/IEC 14443B CEPAS, HID iCLASS
JIS X 6319 Felica
ISO/IEC 18092 SmartPhone with NFC/HCE support, since
Android version 4.3
9155032 Part No.
2N Helios IP Verso
® – 125 kHz RFID Card Reader
The card reader module works with as an OUT card 2N Access Unit
®
reader. The module supports cards, key fobs and/or other 125 kHz
standard carriers: or .EM-41xx HID Proximity

2N TELEKOMUNIKACE a.s., www.2n.cz 14/98
9155031Part No.
2N Helios IP Verso
® – keypad
The numeric keypad module helps enter a numeric entrance code. Use
the keypad for departures or double entrance authentication. The
keypad digits and symbols are backlit.
Part No.
9155031B 2N Helios IP Verso
® – keypad
The numeric keypad module helps enter a numeric entrance code. Use
the keypad for departures or double entrance authentication. The
keypad digits and symbols are backlit.
Part No. 9155037
2N Helios IP Verso
® – Wiegand Module
The Wiegand module helps you interconnect your system with other
systems (access, security) via the Wiegand interface. The module is
installed under another module, i.e. cannot be installed directly into the
(must be mounted outside).2N Access Unit
®
Part No. 9155034
2N Helios IP Verso
®– I/O Module
The logic input/output module helps you integrate various sensors and
control doors or other equipment. The module is installed under
another module, i.e. cannot be installed directly into the 2N Access
®
(must be mounted outside).Unit

2N TELEKOMUNIKACE a.s., www.2n.cz 15/98
9155030Part No.
2N Helios IP Verso
® – Infopanel
The Infopanel module helps you add your company logo, opening
hours and similar information to the access unit. The Infopanel has
software-controlled backlight.
Part Numbers:
1550509
9155054
9155055
1 m Interconnecting Cable
3 m Interconnecting Cable
5 m Interconnecting Cable

2N TELEKOMUNIKACE a.s., www.2n.cz 16/98
Mounting Accessories
Part No.
9155014
Flush mounting box, 1-module
The box is designed for brick/plasterboard flush mounting of a 1-module
installation. Supplied including accessories for multiple box assemblies.
Part No.
9155015
Flush mounting box, 2-module
The box is designed for brick/plasterboard flush mounting of a 2-module
installation. Supplied including accessories for multiple box assemblies.
Part No.
9155061
Backplate, 1 module
A backplate for glass or uneven surface mounting.
Part No.
9155062
Backplate, 2 modules
A backplate for glass or uneven surface mounting.

2N TELEKOMUNIKACE a.s., www.2n.cz 17/98
For the choose the appropriate mounting frame and box 2N® Access Unit installation
if necessary. The is designed for outdoor applications and requires 2N® Access Unit
no additional roof.

2N TELEKOMUNIKACE a.s., www.2n.cz 18/98
Electric Locks
932071EPart No. BEFO 11211
12 V / 230 mA DC
low consumption
932081EPart No. BEFO 11221 with momentum pin
12 V / 230 mA DC
low consumption
For opening of the lock a short electrical impuls is sufficient,
which unlocks the lock. Lock is then open until someone closes
the door.
932091EPart No. BEFO 11211MB with mechanical blocking
12 V / 230 mA DC
low consumption
Enables mechanically close or open the lock. When opened,
the lock is open all the time. When closed, it behaves as
standart electrical lock.
Part No. 932061E
211211 door signalling, low consumption
12 V / 230 mA
A regular lock with a built-in contact to indicate whether the
door is open or closed.

2N TELEKOMUNIKACE a.s., www.2n.cz 19/98
Part No. 932072E 31211 fail-safe
12 V / 170 mA DC
The failsafe lock is closed when electricity is switched on.
When electricity is interrupted, the lock is opened.
Part No. 932062E 321211 fail-safe, door signalling
12 V / 170 mA
The failsafe lock is closed when electricity is switched on.
When electricity is interrupted, the lock is opened.
It contains a built-in contact to indicate whether the door is
open or closed.
Tip
FAQ:Electric locks – Differences between locks for 2N Helios IP
®

2N TELEKOMUNIKACE a.s., www.2n.cz 20/98
Power Supply
Part Numbers:
91378100
91378100E
91378100US
PoE injector – without cable
PoE injetor – with EU cable
PoE injector – with US cable
For power supply of intercom via ethernet cable when PoE switch
is not available.
91341481EPart No. Stabilised 12 V / 2 A power supply needs to be used when no PoE
is available.
932928Part No. For external power supply of the lock with 12 V AC voltage.
Other manuals for Access Unit
5
Table of contents
Other 2N IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Roger
Roger MCT80M-BLE installation manual

Häfele
Häfele WT 210 BLE operating instructions

HIK VISION
HIK VISION DS-K281X Series quick start guide

IDTECK
IDTECK Star iCON100 Quick installation guide

Tyco Security Products
Tyco Security Products Software House IP-ACM quick start guide

ViziT
ViziT KTM602F operating instructions