3M Filtrete FAP02 User manual

1
Table of Contents
• Safety Information
• Warnings & Cautions
• Installation Requirements
Location Requirements
Electrical Requirements
• Features and Functions
• Cleaning & Resetting the Timer
• Air Purier Use Models FAP01, FAP02 & FAP03
Turning the Room Air Purifier On/Off
Adjusting the Fan Speed
Filter Life Diagnostics
•Filter Removal
• Filter Replacement
• Troubleshooting
• Assistance or Service & Warranty
Safety Information:
Please read, understand, and follow all the safety information
contained in these instructions prior to use of the Filtrete™ Ultra
Clean Air Purier. Retain these instructions for future reference.
Intended Use:
The Filtrete™ Air Purier is intended for indoor household use,
using only Filtrete™ brand lters and standard 240V AC wall soc-
ket. This air purier has not been tested with non-Filtrete brand
lters, operated at different voltages or used outdoors. Each of
these misuses could damage the Air Purier and/or create unsafe
operating conditions
Explanation of Signal Words
Warning
Indicates a potentially hazardous
situation, which if not avoided, could
result in death or serious injury.
Caution
Indicates a potentially hazardous
situation, which if not avoided, may
result in minor or moderate injury.
t
p. 1
p. 2
p. 2
p. 3
p. 3
p. 3
p. 4
p. 4
p. 4
p. 4
ULTRA CLEAN AIR PURIFIER

2
t
Warning
To reduce the risk associated with hazardous voltage:
• Plug the power cord correctly and tightly into a properly rated electrical
outlet.
• Do not use the Air Purier if the power cord is frayed or otherwise
damaged.
• Do not touch the power cord with wet hands.
• Disconnect electrical power before servicing the lter.
• For indoor dry location use only. Do not use in an outdoor or in a wet
environment.
• Do not submerge the Air Purier in water.
• Do not modify or attempt to modify this product.
• Do not disassemble the Air Purier.
Except for lter replacement, the Air Purier is not intended
to be serviced and does not contain any serviceable replacement parts
or adjustments.
To reduce risk associated with hazardous voltage, and/or fire:
• Plug the Air Purier into a properly rated electrical outlet.
To reduce the risk associated with hazardous voltage and/or
moving blades:
• Do not place ngers and/or any objects into air and/or motor housing
vents.
To reduce the risk associated with hazardous voltage, and/or fire,
and/or explosion:
• Do not use any combustible or ammable items on or near the Air
Purier.
• Do not spill or spray any liquids or aerosols into the Air Purier or on
the lter.
To reduce the risk associated with fire:
• Do not block any air vents during use.
• Do not place the Air Purier near a heat source.
To reduce the risk associated with various hazards:
• Read and understand the operating manual before using the Air Purier.
• Do not allow children or pets to have unsupervised access to this pro-
duct.
Caution
To reduce the risk associated with environmental contamination:
• Dispose of the Air Purier and lters in accordance with local regula-
tions.
• Replace the lter when the lter change timer begins ashing red. The
lter should be changed after no more than 90 days of continuous use.
Periodic inspection of the lter for damage or blockage is strongly re-
commended.
To reduce the risk associated with falling, and/or impact:
• Do not sit on or place any object on this product.
Location Requirements:
• Select a location where the air intake and ltered air outlet are not
obstructed.
• Place the Air Purier on a at, level surface at least two feet from any heat
source, such as ranges or heaters.
• Do not block the air openings or place the Air Purier on a soft surface
such as a bed, chair or sofa.
• Operate indoors only.
Warning
• For indoor dry location use only. Do not use outdoors or in a wet
environment.
• Do not submerge the Air Purier in water.
• Do not place ngers and/or any objects into air and/or motor housing
vents.
• Do not allow children or pets to have unsupervised access to this
product.
• Do not block any air vents during use.
• Do not use any combustible or ammable items on or near the Air
Purier.
• Do not spill or spray any liquids or aerosols into the Air Purier or on
the lter.
• Do not place the Air Purier near a heat source.
Caution
• Do not sit on or place any object on this product.
Electrical Connection:
• Plug the Air Purier into a
240 V AC wall socket
.
• This plug will t into the electrical outlet. If the plug does not t the
electrical outlet, contact qualied personnel to install the proper outlet.
DO NOT TAMPER with the plug in any way.
Installation Requirements
• Plug the Air Purier into a
240 V AC wall socket
.
• Plug the power cord correctly and tightly into an electrical outlet.
• Do not use the Air Purier if the power cord is frayed or
otherwise damaged.
• Do not touch the cord with wet hands.
Wa r n i n g a n d Ca u t i o n s
in s t a l l a t i o n re q u i r e m e n t s

3
This Air Purier from 3M comes complete with the latest advances in air ltration
technology in a stylish and trend setting design.
Filtration:
Filtrete
™
lters use proprietary technology to provide high ltration efciency and
low airow resistance - the end result is a highly efcient room Air Purier that
operates quietly. This Filtrete lter has electostatically-charged bres that can
capture particles as small as 0.1 micron. The electrostatically charged bres are
most effective when your lter is new and clean. As particles build up on the lter,
they begin to cover up the charged bres. This will reduce the effectiveness of the
lter at capturing additional particles and can occur early in your lter’s life. The
time frame and extent of the reduction will depend upon the actual use conditions
in the room in your home. To maximize the air cleaning in the room that contains
the Air Purier, we recommend that you clean and seal, as much as possible, the
room in which the Air Purier operates; continue to dust surfaces and vacuum on
a normal schedule; and close all windows and doors during operation.
Filter Change Indicator:
The Air Purier is equipped with a state-of-the-art lter life analyzer. Unlike timers
and other conventional lter change indicators, the analyzer recognizes gradual
changes in the lter condition over time and displays a warning signal when it
is time to change the lter. If the Air Purier is used in an environment with high
particle concentrations, such as a room with new carpeting, woodworking, etc.,
the analyzer will detect excessive particle collection and provide a warning to
the user to change the lter. To ensure that the air purier continues to provide
effective air cleaning, the lter should be changed after no more than 90 days of
continuous use. For this purpose, another change indicator is installed to monitor
how long the Air Purier has operated, not just how many days since the lter
was installed. The lter change indicator has been set to indicate lter change
for typical household conditions. A yellow caution light will come on when the
lter is about 80% used, and a red warning light will come on indicating the lter
needs to be changed.
Fe a t u r e s a n d Fu n C t i o n s :
Cleaning:
• Turn the Air Purier off and unplug it before cleaning.
• The outside of the Air Purier can be cleaned with a soft, clean dampened
cloth.
• The ltered air outlet on the top of the unit can be cleaned of dust with a
small, soft brush.
• If you wish to clean the inside of the unit, please only use a dry, soft cloth to
wipe it down.
Resetting the Filter Timer (For FAP01 see instructions included
with the timer):
• To remind users to change the lter every 90 days, a countdown timer is ins-
talled.
• The reset button is located behind the lter.
• When the lter is about 80% used, a yellow light will illuminate as a reminder to
purchase a replacement lter.
• When the lter needs to be changed, the yellow light will turn red. Replace
the lter immediately by following the instructions in the Filter Replacement
section.
• To reset the lter timer, hold down the FILTER CHANGE button for three se-
conds. A red light comes on. Before it disappears, the light will start ashing
quickly as you ontinue to hold the button. The timer is now reset.
Cl e a n i n g a n d re s e t t i n g t h e Fi l t e r t i m e r
Warning
• Read and understand the operating manual before using the Air Purier
Turning the Air Purifier On/Off:
• Be sure the Air Purier is properly plugged into a 240 V AC wall socket.
• A green light will be illuminated with variable intensity on the control knob.The
device does not lter air in this position.
Adjusting the Fan Speed:
• Once the unit is turned on, the fan speed can be adjusted to one of three
settings.
• From the OFF position, turn the control knob clockwise (CW) to the next posi-
tion. On FAP02 and FAP03 a single green light will be circulating in the center of
the knob. The device will be operating at Low Speed.
• The second turn CW is Medium Speed. On FAP02 and FAP03 two opposing
green lights will be circulating.
• The next position is High Speed. On FAP02 and FAP03 three green lights will be
circulating in the center of the knob.
Filter Life Diagnostics (For FAP02 & FAP03):
• At High Speed, the Filter Life Analyzer will perform diagnostics automatically.
Yellow, green, and red lights in the center of the control knob will light in alter-
nating order for 10 seconds. After lter life diagnostics are completed, only one
light will remain on.
• A green light means that the lter is functioning properly and does not need to
be replaced. A yellow light indicates about 80% of the lter has been used, a
red light indicates the lter needs replacement.
• After 30 seconds of illumination, the green light will disappear, while a yellow or
red light may stay lit depending on the lter condition.
• If the device is operating on a speed other than High, you must change the fan
speed to High to conduct the lter life diagonostics.
ai r Pu r i F i e r us e

4
• While holding the device in place with
one hand, release the front cover
with the other hand by grasping and
gently pulling the cover toward you.
• Lift the lter cover and set it aside.
• Remove the used lter by placing
your ngers in the recesses at the
top of the lter and pressing the lter
frame down. The lter will disengage
from the top holding lip and can be
pulled out.
• Dispose of the used lter properly.
• For FAP02 and FAP03 reset the lter
timer by holding down the FILTER
CHANGE button for three seconds.
A red light comes on. Before it
disappears, the light will start ashing
quickly as you continue to hold the
button. The timer is reset.
Fi l t e r re m o v a l
• Remove the plastic wrapper and
paper insert on the Air Purier
replacement lter.
• Place the bottom edge of
replacement lter in the lter slot
and gently push the top of the lter
down in two places, while pushing
it forward. When the lter clears the
holding lip, release the lter.
• Replace the front cover by placing
the bottom tabs of the cover into the
cavities in the base of the Air Purier.
Push the top of the cover towards
the device until the cover locks into
place.
Caution
• Dispose of the Air Purier, and lters
in accordance with local regulations.
• On FAP01 replace the lter when
the lter change timer nishes its
rotation.
• On FAP02 and FAP03 replace the
lter when the lter change timer
begins ashing red. Change the lter
after at least 90 days continuous
use or sooner depending upon the
conditions in your home.
• Periodic inspection of the lter for
damage or blockage is strongly
recommended.
Fi l t e r re P l a C e m e n t
Warning
• Do not modify or attempt to modify
this product.
• Do not disassemble the Air Purier.
• Except for lter replacement, the Air
Purier is not intended to be serviced
and does not contain any serviceable
replacement parts or adjustments.
trouble
If replacement filter doesn’t fit:
• Check the model number to ensure
the lter matches the model number.
• Make sure that the bottom of the
lter is placed and centered on the
protrusion at the bottom of the lter
opening.
• A small downward force is needed to
place the lter in the opening.
• Make sure that no foreign objects are
blocking the lter opening.
Air Purifier will not turn on:
• Be sure the Air Purier is properly
plugged into a 240V AC wall socket.
• Be sure the Air Purier is turned on.
• Check if the fuse is blown or if a
circuit breaker has been tripped.
Decreased airflow:
• Clean the Air Purier to make sure
that the air inlet and ltered air outlet
are free from blockages.
• Check the condition of the lter and, if
dirty, replace with a new lter.
Noisy operation:
• Check the condition of the lter and if
dirty, replace with a new lter.
• Be sure that nothing is blocking the
air inlet and ltered air outlet.
EEC Statement:
• This machine was tested against the
89/336/EEC (European Economic
Community) for EMC (Electro
Magnetic Compatibility) and fullls
these requirements.
• This machine was tested against
the 73/23/EEC (European
Economic Community) for LVD (Low
Voltage Directive) and fullls these
tr o u b l e s h o o t i n g
requirements.
• This product is compliant
with EU Directive
2002/95/EC (Restriction
of Hazardous Substances
in Electrical and Electronic
Equipment), as amended
by Commission Decision
2005/618/EC on maximum
concentration values.
• This product is compliant
with EU Directive 2002/96/
EC on Waste Electrical
and Electronic Equipment
(WEEE).
IMPORTANT
INFORMATION
FOR CORRECT
DISPOSAL OF
THE PRODUCT IN
ACCORDANCE WITH EC
DIRECTIVE 2002/96/EC.
At the end of its working
life, the product must not be
disposed of as urban waste.
It must be taken to a special
local authority differentiated
waste collection centre
or to a dealer providing
this service. Disposing of
a household appliance
separately avoids possible
negative consequences for
the environment and health
deriving from inappropriate
disposal and enables the
constituent materials to
be recovered to obtain
signicant savings in energy
and resources. As a reminder
of the need to dispose
of household appliances
separately, the product is
marked with a crossed-out
wheeled dustbin.
t
Other manuals for Filtrete FAP02
1
This manual suits for next models
4
Other 3M Air Cleaner manuals

3M
3M mini air ionizer 960 User manual

3M
3M FAP04-RC - 3M Filtrete Ultra-Slim Room Air... User manual

3M
3M Filtrete FAP-C01 Series User manual

3M
3M Filtrete FAP-TT-ADH Series User manual

3M
3M Filtrete FAP-C01BA-G1 Series User manual

3M
3M FAP00-RS User manual

3M
3M Filtrete FAP02 User manual

3M
3M Filtrete FAP-T03-A2 Series User manual

3M
3M Versaflo TR-600 Series User manual

3M
3M Filtrete FAP04 User manual