manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3M
  6. •
  7. Water Filtration System
  8. •
  9. 3M Shower Filter User manual

3M Shower Filter User manual

Other 3M Water Filtration System manuals

3M Aqua-Pure AP817 User manual

3M

3M Aqua-Pure AP817 User manual

3M Triple Manifold Water Filtration Systems User manual

3M

3M Triple Manifold Water Filtration Systems User manual

3M Aqua-Pure AP717 User manual

3M

3M Aqua-Pure AP717 User manual

3M Aqua-Pure AP200 User manual

3M

3M Aqua-Pure AP200 User manual

3M Aqua-Pure AP717 User manual

3M

3M Aqua-Pure AP717 User manual

3M VB2/HC111-S Quick guide

3M

3M VB2/HC111-S Quick guide

3M Aqua-Pure AP1610SS User manual

3M

3M Aqua-Pure AP1610SS User manual

3M TFS450 User manual

3M

3M TFS450 User manual

3M Aqua-Pure AP800 Series User manual

3M

3M Aqua-Pure AP800 Series User manual

3M Aqua-Pure AP801 Housing Supplement

3M

3M Aqua-Pure AP801 Housing Supplement

3M 3MWTS100 User manual

3M

3M 3MWTS100 User manual

3M DIDF260-CL Owner's manual

3M

3M DIDF260-CL Owner's manual

3M SH-EXP User manual

3M

3M SH-EXP User manual

3M SCALEGARD SGLP-RO User manual

3M

3M SCALEGARD SGLP-RO User manual

3M DP1 Series User manual

3M

3M DP1 Series User manual

3M HF05-MS User manual

3M

3M HF05-MS User manual

3M 6000 User manual

3M

3M 6000 User manual

3M ScaleGard HP Reverse Osmosis System User manual

3M

3M ScaleGard HP Reverse Osmosis System User manual

3M Aqua-Pure AP717 User manual

3M

3M Aqua-Pure AP717 User manual

3M CS-340 Series Quick guide

3M

3M CS-340 Series Quick guide

3M Aircare ACU-03 User manual

3M

3M Aircare ACU-03 User manual

3M PS114 User manual

3M

3M PS114 User manual

3M Aqua-Pure APIL3 User manual

3M

3M Aqua-Pure APIL3 User manual

3M Filtrete Standard User manual

3M

3M Filtrete Standard User manual

Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

Atlantic Ultraviolet

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun CBG-500 Operation manual

SunSun

SunSun CBG-500 Operation manual

Hayward XStream Filtration Series owner's manual

Hayward

Hayward XStream Filtration Series owner's manual

Contech DownSpout StormFilter Operation and maintenance

Contech

Contech DownSpout StormFilter Operation and maintenance

Teka Airfilter MINI operating instructions

Teka

Teka Airfilter MINI operating instructions

Wisy LineAir 100 Installation and operating instructions

Wisy

Wisy LineAir 100 Installation and operating instructions

Schaffner Ecosine FN3446 Series User and installation manual

Schaffner

Schaffner Ecosine FN3446 Series User and installation manual

Pentair FLECK 4600 SXT Installer manual

Pentair

Pentair FLECK 4600 SXT Installer manual

H2O International H20-500 product manual

H2O International

H2O International H20-500 product manual

Renkforce 2306241 operating instructions

Renkforce

Renkforce 2306241 operating instructions

Neo-Pure TL3-A502 manual

Neo-Pure

Neo-Pure TL3-A502 manual

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

STA-RITE

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

Applied Membranes W-G844EM Operation and maintenance manual

Applied Membranes

Applied Membranes W-G844EM Operation and maintenance manual

BEGA 116 Instructions for use

BEGA

BEGA 116 Instructions for use

WATA Standard operating instructions

WATA

WATA Standard operating instructions

Price FFU series Installation and service manual

Price

Price FFU series Installation and service manual

Gaggenau BRITA INTENZA 467873 manual

Gaggenau

Gaggenau BRITA INTENZA 467873 manual

Brita SAFF-100 user guide

Brita

Brita SAFF-100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Shower Filter
USER MANUAL
CASE A
CASE B
CASE C
CASE D
CASE E
CASE E
CASE D
There is a foreign substance in the large rubber
ring (O-ring) mounted under the body, which may
cause intermittent leakage.
Or it may not be properly tightened.
After removing the bottom, lightly wash the
O-ring part with water and reassemble.
If the shower hose is not properly tightened.
Refit until no more turns.
Are there any leaks between
the body and bottom?
Is there a leak between the tail and
the shower hose?
CASE B
CASE A
If there is no rubber stopper (gasket) in the nut joint, water leakage may occur, or the proper
tightening between the nut joint and the faucet may not work. Tighten the nut joint further until it
no longer turns. If necessary, use a spanner. Do not turn the shower filter (head/body) at this time,
as there is a risk of damage.
Product assembly is defective.
Please return or exchange after contacting our.
Is there a leak between the nut joint and the faucet?
Are there any leaks between the nut joint and the head?
CASE C
The small rubber ring (O-ring) mounted on the body may contain foreign substances, causing
intermittent leakage. After separating the body and head, wash the rubber ring lightly with water
and reassemble.
Are there any leaks between the head and body?
3M™ shower filter self-diagnosis and solution
If there is any leakage after installing the product, please see self-diagnosis for the five cases below.
We do not compensate for loss due to incorrect use or carelessness, and if a problem occurs
with this product, we will refund the purchase price or exchange the purchased product.
This 3M product is a registered trademark of 3M Corporation.
This product can be compensated according to the consumer dispute resolution
standards in accordance with the Consumer Protection Act.
*
*
*
Korea 3M Co., Ltd.
Filter Product Business Team
18th floor, 82 Uidang-daero, Yeongdeungpo-gu, Seoul
Customer Service Office 080-033-4114
www.3m.co.kr
Nut joint
Head
Body
Bottom
Tail
Filter replacement time
Filter replacement is recommended when the 3M logo is clearly visible.
Based on daily usage for adults (40L), the filter replacement cycle is 2-4 months,
There may be differences depending on the usage environment.
NEW OLD
How to replace 3M™ shower filter refill
01
Pull the shower filter
head lock to separate
it from the body.
02
Twist the separated
body in the direction
of the arrow.
03
Replace the dirty
filter with a new
one.
04
After assembling in
reverse order, reinstall
the shower filter.
When replacing the shower filter, intermittent leakage may occur due to the
rubber ring getting caught between the body and the head or bottom.
At this time, separate the product and parts, soak the rubber ring in water
sufficiently, and then reassemble it.
!
How to install 3M™ shower filter
01
Remove the shower
hose from the
faucet.
02
Connect the 3M™
shower filter to the
bottom of the faucet.
03
Connect the separated
hose to the bottom of
the 3M™ shower filter.
If the distance between the faucet and the wall is too close, it cannot be mounted.
Install at least 6cm away from the wall.
!
When installing/replacement of the shower filter, if the head is
rotated, there is a risk of damage, so never turn the head.
!Precautions for use
Can only be used in tap water, not recommended for unidentified water or water containing microorganisms.
Please check the water pressure before installation. For high water pressures of about 4.0kg/cm2 or more,
consult an expert before installing a pressure reducing device.
It is not recommended for use with valved shower heads.
When installing the product, it is possible to tighten it by hand. It can be installed with a separate tool, but if it is
tightened too strongly, there is a risk of product damage.
If the head is rotated excessively after installing the product, the safety pin may come off. The safety pin serves
to fix the head, and even if the pin is removed, there is no problem in using the product.
After installing the product, run water for at least 5 seconds before use.
In the case of premium shower filter, water mixed with activated carbon powder flows out during the first use,
so please pass water through it for 1-2 minutes or more.
We recommend using the water in the inn only for shower purposes, not for drinking.
The main material is PC (polycarbonate), please use it at about 4-45°C.
Do not lubricate the rubber O-ring or clean the product with chemicals.
Replace it when the filter is dirty or the water pressure is weak.
Please check the color of the filter regularly to prevent the flow rate decrease due to clogging of the fllter.
The replacement cycle may vary depending on the water environment and water usage conditions.
Avoid direct sunlight when using or storing.
3M™ shower filter is compatible with both standard and premium.
If an external force is applied to the filter after installing the filter, the product may be damaged.