manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Server
  8. •
  9. 3One data NP318T-8DI Operating and maintenance instructions

3One data NP318T-8DI Operating and maintenance instructions

NP3XXT Series
Serial Device Server
Quick Installation Manual
Shenzhen 3onedata Technology Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District, Shenzhen
Website:
www.3onedata.com
Te l :
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check whether the package and accessories are intact
while using the serial device server for the first time.
1. Serial Device Server
2. Quick installation manual
3. Wall mount kit
4. Straight-through cable
5. Power adapter
6. Warranty card
7. CD
8. Qualify certificate
9. Two pairs of rubber
shock absorbers pad
10. RJ45 (3IN1 serial port) to
DB9-Male conversion line
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
The product is managed industrial serial device server.
Module as follow:
Model I. NP304T-4D(3IN1)-RJ45:
4-Port RS-232/485/422 + 1-port 10/100Base-T(X)
Model II. NP314T-4D(3IN1)-RJ45:
4-Port RS-232/485/422 + 2-port 10/100Base-T(X)
Model III. NP308T-8D(3IN1)-RJ45:
8-Port RS-232/485/422 + 1-port 10/100Base-T(X)
Model IV. NP318T-8D(3IN1)-RJ45:
8-Port RS-232/485/422 + 2-port 10/100Base-T(X)
Model V. NP304T-4DI (RS485):
4-Port RS-485/422 + 1-port 10/100Base-T(X)
Model VI. NP314T-4DI (RS485):
4-Port RS-485/422 + 2-port 10/100Base-T(X)
Model VII. NP308T-8DI (RS-485):
8-Port RS-485/422 + 1-port 10/100Base-T(X)
Model VIII. NP318T-8DI (RS-485):
8-Port RS-485/422 + 2-port 10/100Base-T(X)
【Panel Design】
Top view
Bottom view
Front view
Rear view
1. Power indicator
2. Running status indicator
3. Ethernet port Link/ACT indicators
4. Serial port transmission and receiving data
indicators
5. Rubber shock absorber pad
6. Screw holes for Wall Mounting Kit
7. RS-232/485/422 serial ports
8. RS-485/422 serial ports
9. Power input terminal block
10. Grounding screw
11. DIP switch
12. Console port
13. 10/100Base-T(X) Ethernet ports
【Mounting Dimension】
Unit: mm
Model I ~Model VI
Model VII, Model VIII
Note Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running,
please don't directly contact to avoid scalding.
【Wall Mounting】
Mounting the Device
Step 1 Adopt M3 screw to install the left/right mounting
board on the device backboard.
Step 2 On the wall of device mounting, place the device on
the wall for reference or reference the mounting
dimension to mark the four screws position.
Step 3 Nail two M4 screws on the wall and keep 2mm
interspace reserved.
Step 4 Hang the device on two screws and slide
downward, then tighten the screw to enhance
stability, mounting ends.
Device Disassembling
Step 1 Device power off.
Step 2 Unscrew the screw on the wall about 2mm.
Step 3 Lift the device upward slightly, take out the device,
disassembling ends.
【Power Supply Connection】
DC power supply
The serial device server provides 3 industrial
terminal blocks, in which V+ and V- are DC
input and FG is ground input. The power
supply has nonpolarity and anti-reverse functions, Power
supply range: 12~48VDC.
Note:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Console Port Connection】
The device provides 1 channel procedure
debugging port based on RS-232 serial port.
The interface adopts RJ45 port. The PIN
definition as follows.
PIN 2 3 5
PIN definition TXD RXD GND
【DIP Switch Setting】
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal. Please
power off and power on after changing the status of DIP
switch. DIP switch definition as follow:
1. Reserved 2. Restore factory setting
3. Reserved 4. Reserved
【Serial Port Connection】
RS-232/485/422 Port (3IN1)
Model I, model II, model III, and model IV
provide RS-232/485/422 port(3IN1), serial
device server adopts RJ45 connector. The
PIN definition as follows.
PIN 1 2 3 4 5 6 7 8
RS-232
DSR
RTS
GND
TXD
RXD
DCD
CTS
DTR
RS-485
—
—
GND
—
—
D-
—
D+
RS-422
—
R-
GND
R+
—
T-
—
T+
RS-485/422 Port
1 8
1 8
Model V, model VI, model VII, and model
VIII provide RS-485/422 port, Serial
device server adopts 5-pin 5.08mm pitch
terminal block. The PIN definition as
follows.
PIN 1 2 3 4 5
RS-422 T+ T- GND R+ R-
RS-485 D+ D- GND — —
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Indicate
Description
PWR
ON The power connection is operating
normally.
OFF The power is not connected or is
not working properly.
RUN
ON
The system is not working properly.
Flashing
The system is running normally.
OFF The system is not running or
running abnormally.
LINK
(1~2)
ON
The Ethernet interface has
established an active network
connection.
Flashing The Ethernet interface is in a
network activity state.
OFF
The Ethernet interface does not
establish an active network
connection.
RX
Port(1~4/8
)
OFF
No data or abnormal data is being
received through serial port.
Flashing
Serial port is receiving data.
TX
Port(1~4/8
)
OFF
No data or abnormal data is being
transmitted through serial port.
Flashing
Serial port is transmitting data.
【Specification】
Panel
10/100Base-T(X) 10/100Base-T(X) self-adapting
RJ45 port
Serial Port
RS-232/485/422 (3IN1) RJ45
interface or RS-485/422
terminal block
Console port
RJ45
Indicator
Power indicator, Running status
indicator, Ethernet port Link/Act
indicator, Serial port
transmission and receiving data
indicator
Power supply
Input power supply
12~48VDC
Access terminal
3-pin terminal block
Consumption
NP304T-4D(3IN1)-RJ45
NP314T-4D(3IN1)-RJ45
No-load: 2.16W@12VDC
Full-load: 3.00W@12VDC
NP308T-8D(3IN1)-RJ45
NP318T-8D(3IN1)-RJ45
No-load: 1.8W@12VDC
Full-load: 3.9W@12VDC
NP304T-4DI(RS-485)
NP314T-4DI(RS-485)
No-load: 2.94W@12VDC
Full-load: 2.94W@12VDC
NP308T-8DI(RS-485)
NP318T-8DI(RS-485)
No-load: 3.16W@12VDC
Full-load: 3.72W@12VDC
Working environment
NP304T-4D(3IN1)-RJ45
NP314T-4D(3IN1)-RJ45
NP308T-8D(3IN1)-RJ45
NP318T-8D(3IN1)-RJ45
Working temperature: -40℃~
75℃
Storage temperature: -40℃~
85℃
NP304T-4DI(RS-485)
NP314T-4DI(RS-485)
Working temperature: -40℃~
75 ℃
Storage temperature: -40℃~
75
℃
NP308T-8DI(RS-485)
NP318T-8DI(RS-485)
Working temperature: -40℃~
70℃
Working temperature: -40℃~
70
℃
Working humidity
5%~95% (no condensation)
Physical Characteristics
Protection grade
IP30
Size (L×W×H) 170mm×110mm×31.50mm/
170mm×110mm×49.80mm
Weight 580g
Mounting
Wall Mounting

Other manuals for NP318T-8DI

2

This manual suits for next models

8

Other 3One data Server manuals

3One data NP30XT series User manual

3One data

3One data NP30XT series User manual

3One data NP302T Series User manual

3One data

3One data NP302T Series User manual

3One data NP5100 Series User manual

3One data

3One data NP5100 Series User manual

3One data NP301 User manual

3One data

3One data NP301 User manual

3One data NP308T-8D User manual

3One data

3One data NP308T-8D User manual

3One data ICP222-2F-2CI Operating and maintenance instructions

3One data

3One data ICP222-2F-2CI Operating and maintenance instructions

3One data NP318T-8DI User manual

3One data

3One data NP318T-8DI User manual

3One data NP301 Operating and maintenance instructions

3One data

3One data NP301 Operating and maintenance instructions

3One data CP202-2CI User manual

3One data

3One data CP202-2CI User manual

3One data NP316Series User manual

3One data

3One data NP316Series User manual

3One data NP316 User manual

3One data

3One data NP316 User manual

3One data NP3116T Series User manual

3One data

3One data NP3116T Series User manual

3One data NP Series User manual

3One data

3One data NP Series User manual

3One data NP5100 Series User manual

3One data

3One data NP5100 Series User manual

3One data NP5000 Series User manual

3One data

3One data NP5000 Series User manual

3One data CP202-2CI User manual

3One data

3One data CP202-2CI User manual

3One data NP3 T Series Operating and maintenance instructions

3One data

3One data NP3 T Series Operating and maintenance instructions

3One data NP318T-8DI User manual

3One data

3One data NP318T-8DI User manual

3One data NP302T Series User manual

3One data

3One data NP302T Series User manual

Popular Server manuals by other brands

Lenovo 7X12 reference guide

Lenovo

Lenovo 7X12 reference guide

Lenovo ThinkServer TS100 Installationshandbuch

Lenovo

Lenovo ThinkServer TS100 Installationshandbuch

HP ProLiant Server troubleshooting guide

HP

HP ProLiant Server troubleshooting guide

Supero AS2021M-T2R+ user manual

Supero

Supero AS2021M-T2R+ user manual

Intel SR1325TP1 - Entry Server Platform user guide

Intel

Intel SR1325TP1 - Entry Server Platform user guide

IBM Power 720 Express 8202-E4B manual

IBM

IBM Power 720 Express 8202-E4B manual

IBM BladeCenter HS22 supplementary guide

IBM

IBM BladeCenter HS22 supplementary guide

Honeywell Uniformance R300 user guide

Honeywell

Honeywell Uniformance R300 user guide

HP ProLiant DL320G5p/X3075 Disassembly instructions

HP

HP ProLiant DL320G5p/X3075 Disassembly instructions

HP Integrity rx2600 Operation and maintenance guide

HP

HP Integrity rx2600 Operation and maintenance guide

Sybase Adaptive Server 15.0.2 installation guide

Sybase

Sybase Adaptive Server 15.0.2 installation guide

Supermicro A+ Server AS -2115GT-HNTF user manual

Supermicro

Supermicro A+ Server AS -2115GT-HNTF user manual

Moxa Technologies NPort IA5150 series Quick installation guide

Moxa Technologies

Moxa Technologies NPort IA5150 series Quick installation guide

Axis 2411 Administration manual

Axis

Axis 2411 Administration manual

Acer AC100 Service guide

Acer

Acer AC100 Service guide

Sun Microsystems Fire X4600 manual

Sun Microsystems

Sun Microsystems Fire X4600 manual

HP ProLiant 400 Limited warranty

HP

HP ProLiant 400 Limited warranty

Lantronix ETS Reference manual

Lantronix

Lantronix ETS Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.