NP5000 Series
Serial Server Quick Installation
Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District, Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check whether the package and accessories are intact
while using the device for the first time.
1.
Serial Server
2.
Quick installation guide
3.
CD
4.
Lugs
5.
Power adapter
6.
Straight-through cable
7.
Certification
8.
Warranty card
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
The products are desktop safe serial servers, including the
following models:
Model I. NP5000-1T-1DI(3IN1)-DB-P(12-48VDC) (1 100M
copper port + 1 3IN1 DB9 serial port with isolation +
1 12~48VDC power supply)
Model II. NP5000-1T-2DI(3IN1)-DB-P(12-48VDC) (1 100M
copper port + 2 3IN1 serial ports with isolation + 1
12~48VDC power supply)
Model III. NP5000-2T-4DI(3IN1)-RJ-P(12-48VDC) (2 100M
copper ports + 4 3IN1 RJ45 serial ports with
isolation + 1 12~48VDC power supply)
Model IV. NP5000-2T-8DI(3IN1)-RJ-P(12-48VDC) (2 100M
copper ports + 8 3IN1 RJ45 serial ports with
isolation + 1 12~48VDC power supply)
【Panel Design】
Model I
Model II
Model III
Model IV
1. 100M copper port
2. Reset button
3. Terminal block 1 for power input
4. Power indicator
5. Running indicator
6. Copper port connection indicator
7. Serial port transmission data indicators
8. Serial port receiving data indicators
9. Lugs
10. RS-485/422/232 DB9 serial port
11. RS-485/422/232 RJ45 serial port
12. Grounding screw
13. Terminal block 2 for power input
14. Console port
【Mounting Dimension】
Unit: mm
Model I, Model II
Model III, Model IV
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Wall-mounted Device Mounting】
Model I, Model II
Step 1 On the wall of device mounting, place the device on
the wall for reference or refer to the mounting
dimension to mark two screw positions.
Step 2 Nail M4 screws on the wall and keep 2mm
interspace reserved.
Step 3 Hang the device on two screws and slide
downward, then tighten the screw to enhance
stability, mounting ends.
Model III, Model IV
Step 1 Adopt M3 screw to install the left/right mounting
board on the device backboard.
Step 2 On the wall of device mounting, place the device on
the wall for reference or refer to the mounting
dimension to mark two screw positions.
Step 3 Nail M4 screws on the wall and keep 2mm
interspace reserved.
Step 4 Hang the device on two screws and slide
downward, then tighten the screw to enhance
stability, mounting ends.
【Wall-mounted Device Disassembling】
Step 1 Device power off.
Step 2 Unscrew the screw on the wall about 2mm.
Step 3 Lift the device upward slightly; take out the device,
disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Power Supply Connection】
Model I, Model II
This device provides 1 DC power supply input
which is 3-pin 5.08mm pitch terminal block, the
power supply supports non-polarity and
anti-reverse connection. Power supply range: 12-48VDC. The
pin definitions of the terminals are shown as follows:
PIN 1 2 3
Definition V+ FG V-
Model III, Model IV
The model III and model IV of this series provide 1
DC power supply input terminal blocks that adopts , in which
V+ and V- are DC input, FG is the power grounding input; The
power supply supports non-polarity, power supply range: 12~
48VDC.
【Reset Button Setting】
This series device provides 1 reset button, press the button for
4-5S then release it to restore factory defaults.
【Serial Port Connection】
RS-485/422/232 DB9 serial port
The model I and model II of this series
provide 1/2 3IN1 DB9 serial port, which
supports RS-232, RS-485 and RS-422 at
the same time. The interface type is DB9 male and its pin
definitions are as follows:
PIN
RS-232
RS-422
RS-485
1 - T+ D+
2 RXD T- D-
3 TXD R+ -
4 DTR R- -
5 GND GND GND
6 DSR - -
7 RTS - -
8 CTS - -
9 - - -
RS-485/422/232 RJ45 serial port
The model III and model IV of this series
provide 4/8 3IN1 RJ45 serial port, which
supports RS-232, RS-485 and RS-422 at the
same time. The interface type is RJ45 and its pin definitions
are as follows:
PIN 1 2 3 4 5 6 7 8
RS-232
DSR
RTS
GND
TXD
RXD
DCD
CTS
DTR
RS-485
—
—
GND
—
—
D-
—
D+
RS-422
—
R-
GND
R+
—
T-
—
T+
【Console Port Connection】
The Model III and Model IV provide 1 program
debugging port based on RS232 serial port
which can conduct device CLI command line
management after connected to PC. The
interface adopts RJ45 port, the RJ45 pin definition as follows:
Pin No.
2
3
5
Pin Definition
TXD
RXD
GND
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the detailed status of each LED is described
in the table as below:
LED
Indicate
Description
PWR
ON PWR is connected and running
normally
OFF PWR is disconnected and
running abnormally
RUN
Blinking The system is running normally
OFF
The system is not running or
running abnormally
ON System is running abnormally
LINK(1-2)
ON Copper port has established an
active network connection.
Blinking Copper port is in a network
activity state.
OFF
Copper port has not
established an active network
connection
TX(1-2/4/8)
OFF
Serial port is not transmitting
data or transmitting data
abnormally
Blinking Serial port is transmitting data.
RX(1-2/4/8)
OFF Serial port is not receiving data
or receiving data abnormally
Blinking Serial port is receiving data.
【Logging in to WEB Interface】
1 8
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below:
Step 1 Configure the IP addresses of computer and the
device to the same network segment(The network
segment of Model I, Model II is 1; and the network
segment of network port 1 of Model III and Model
IV is 1, the network segment of network port 2 is 8 ),
and the network between them can be mutually
accessed.
Step 2 Enter device’s IP address in the address bar of the
computer browser.
Network Port 1:
Network Port 2:
Step 3 Enter device’s username and password in the login
window as shown below.
Step 4 Click “Login” button to login to the WEB interface of
the device.
Note:
The default IP address of the network ports of model I
and model II is "192.168.1.254"; The default IP address
of network port 1 of model III and model IV is
"192.168.1.254", and the default IP address of network
port 2 is "192.168.8.254".
The default user name and password of the device are
“admin”.
If the user name or password is lost, user can restore it
to factory settings via restore button or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
100M Copper Port 10/100Base-T(X) self-adapting
RJ45 port
Serial Port 3IN1 RJ45 interface or 3IN1 DB9
interface with isolation
Indicator
Power indicator, Running
indicator, Copper port connection
indicator, Serial port transmission
and receiving data indicator
Power supply
Input power supply
12~48VDC
Access terminal block 3-
pin 5.08mm pitch terminal
blocks
Power consumption
Model I, Model II No-load: 0.9W@12VDC
Full-load: 1.1W@12VDC
Model III, Model IV No-load: 3.4W@12VDC
Full-load: 4.1W@12VDC
Working Environment
Working temperature
-40
~
75
℃
Storage temperature
-40
~
85℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP30(metal shell)

This manual suits for next models

4

Other 3One data Server manuals

3One data NP Series User manual

3One data

3One data NP Series User manual

3One data NP318T-8DI User manual

3One data

3One data NP318T-8DI User manual

3One data NP316 User manual

3One data

3One data NP316 User manual

3One data NP318T-8DI Operating and maintenance instructions

3One data

3One data NP318T-8DI Operating and maintenance instructions

3One data NP301 Operating and maintenance instructions

3One data

3One data NP301 Operating and maintenance instructions

3One data NP5100 Series User manual

3One data

3One data NP5100 Series User manual

3One data NP316Series User manual

3One data

3One data NP316Series User manual

3One data NP5100 Series User manual

3One data

3One data NP5100 Series User manual

3One data NP302T Series User manual

3One data

3One data NP302T Series User manual

3One data NP3 T Series Operating and maintenance instructions

3One data

3One data NP3 T Series Operating and maintenance instructions

3One data NP301 User manual

3One data

3One data NP301 User manual

3One data NP302T Series User manual

3One data

3One data NP302T Series User manual

3One data NP30XT series User manual

3One data

3One data NP30XT series User manual

3One data NP308T-8D User manual

3One data

3One data NP308T-8D User manual

3One data NP318T-8DI User manual

3One data

3One data NP318T-8DI User manual

3One data CP202-2CI User manual

3One data

3One data CP202-2CI User manual

3One data NP3116T Series User manual

3One data

3One data NP3116T Series User manual

3One data CP202-2CI User manual

3One data

3One data CP202-2CI User manual

3One data ICP222-2F-2CI Operating and maintenance instructions

3One data

3One data ICP222-2F-2CI Operating and maintenance instructions

Popular Server manuals by other brands

NEC Express5800/B120e user guide

NEC

NEC Express5800/B120e user guide

NEC N8146-43 user guide

NEC

NEC N8146-43 user guide

Lenovo NeXtScale nx360 M5 Installation and service guide

Lenovo

Lenovo NeXtScale nx360 M5 Installation and service guide

AIC HA401-VG user manual

AIC

AIC HA401-VG user manual

Rosewill RSV-Z4000 user manual

Rosewill

Rosewill RSV-Z4000 user manual

Intel STCK1A32WFC user guide

Intel

Intel STCK1A32WFC user guide

Grandstream Networks IPVT10 user guide

Grandstream Networks

Grandstream Networks IPVT10 user guide

Digimerge DNS1010 Quick installation guide

Digimerge

Digimerge DNS1010 Quick installation guide

HP Tc2100 - Server - 128 MB RAM installation guide

HP

HP Tc2100 - Server - 128 MB RAM installation guide

Fujitsu FUTRO S5010 operating manual

Fujitsu

Fujitsu FUTRO S5010 operating manual

GeoVision GV-GIS user manual

GeoVision

GeoVision GV-GIS user manual

Advantech BB-VESP211 Series user manual

Advantech

Advantech BB-VESP211 Series user manual

Mitsubishi Electric MES3-255C-EN user manual

Mitsubishi Electric

Mitsubishi Electric MES3-255C-EN user manual

Symantec NetBackup 5200 Series troubleshooting guide

Symantec

Symantec NetBackup 5200 Series troubleshooting guide

ClearView Venue Player System guide

ClearView

ClearView Venue Player System guide

Cooper CEAG EGA / COM-Server instruction manual

Cooper

Cooper CEAG EGA / COM-Server instruction manual

Acer Altos G701 user guide

Acer

Acer Altos G701 user guide

Allworx Connect Series installation guide

Allworx

Allworx Connect Series installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.