Acrel ASJ10-GQ User manual

180
ASJ10-GQ Self-resetting over-voltage and
under-voltage protector
Installation and Operation Manual V1.1
Acrel CO., Ltd.

declare
All rights reserved. Without the written permission of the company, the contents of any paragraphs and
chapters in this manual shall not be excerpted, copied or copied or disseminated in any other form, otherwise
all consequences shall be borne by the offender.
The company reserves all legal rights.
The company reserves the right to modify the product specifications described in this manual without notice.
Before placing an order, please consult your local agent for the latest specifications of this product.

Contents
1General....................................................................................................................................... 1
2Features.......................................................................................................................................1
3Model and meaning...................................................................................................................... 1
4main parameter.............................................................................................................................2
5external structure.......................................................................................................................... 3
6Installation wiring.........................................................................................................................4
7Operation guide............................................................................................................................5
8Application example..................................................................................................................... 6
9Order example..............................................................................................................................7

1
1General
ASJ10-GQ series Self-resetting over-voltage and under-voltage protector(referred to as ASJ) is suitable for
single-phase AC voltage 230V or three-phase voltage 400V, frequency 45-65Hz,Users or loads with rated
working current up to and including 63A. When the single-phase or three-phase line over-voltage or under
voltage is caused by the neutral line fault, the protective device is opposite to the electrical equipment
Protection.
ASJ series products have the functions of over-voltage, under voltage protection and automatic delay
reset of line normal voltage. The products are mainly used in the residential box The protection of incoming
line or single-phase or three-phase electrical equipment distribution line, with small volume, high precision,
compact structure and convenient installation, is the safety in the field of civil construction Full protection
device.
2product features
■ auxiliary power supply AC230V (phase voltage).
■ cut off the line in case of over-voltage and under voltage, reset the line automatically after the line voltage
returns to normal, and connect the line without manual operation.
■ voltage measurement range: AC50v-290v, frequency 50Hz ± 5Hz, product power consumption is not more
than 3W.
■ impulse withstand voltage: 4KV.
■ the working state is indicated by the two-color diode of the protector, the green light is normally on - the
voltage is normal; the red light is fast flashing - over-voltage; the red light is slow flashing - under voltage;
the red light is normally on-Open phase / fault.
■ output capacity of relay: it can withstand the over-current of 120% current level of shell frame.
■ wiring mode: up in down out.
■ electrical life: 10000 times.
■ the product is installed on the outgoing side of the main switch of the household box.
3Model and meaning
The ASJ model description is shown in Figure 1.
Figure 1 Product model description

2
Table 1 Product selection instructions
Frame current
series:1P series:3P
25A ASJ10-GQ-1P-25 ASJ10-GQ-3P-25
32A ASJ10-GQ-1P-32 ASJ10-GQ-3P-32
40A ASJ10-GQ-1P-40 ASJ10-GQ-3P-40
50A ASJ10-GQ-1P-50 ASJ10-GQ-3P-50
63A ASJ10-GQ-1P-63 ASJ10-GQ-3P-63
4 main parameters
Table 2 Technical parameters
technical parameter
working voltage 1P AC230V 50Hz
3P AC400V 50Hz
working frequency 50Hz
Over voltage trip(L-N) 275VAC±5V
Over voltage trip time
Over voltage action setting
value 250V 275V 300V 350V 400V
Maximum time no
actio
n
15s 3s 0.75s 0.2s
Default time 5s 2s 0.5s 0.15s
Minimum non driving time 3s 1s 0.25s 0.1s
Over voltage recovery (L-N) 255VAC±5V
Under voltage trip (L-N) 160VAC±5V
Under voltage trip time 1s
Under voltage recovery (L-N) 195VAC±5V
Self recovery forced delay 30s
Wiring mode Up in down out
Electrical life 10000 times
Protection level noumena IP20
Environment
Working environment temperature -5℃~+40℃
Storage ambient temperature -20℃~+60℃
humidity ≤95%
altitude ≤2000m
Pollution level Level 2
Installation category Ⅲ

3
5external structure
The appearance structure and dimensions of single-phase self-resetting over-voltage and under-voltage
protectors are shown in Figure 2.
Figure 2
The appearance structure and dimensions of three-phase self-resetting over-voltage and under-voltage
protectors are shown in Figure 3.
Figure 3

4
6 Installation wiring
Installation Notes:
ASJ adopts rail installation, directly installed on 35mmDIN rail, the installation and wiring diagram of
single-phase self-resetting over-voltage and under-voltage protector products is shown in Figure 4
Figure 4
The installation and wiring diagram of the three-phase self-resetting over-voltage and under-voltage
protector is shown in Figure 5.
Figure 5
Wiring instructions:
Screw size: M6; Rated torque: 3.5Nm; Ultimate torque: 5.6Nm; Copper wire: 1~30mm² hard wire/1~
25mm² soft wire (or hoop terminal).

5
7 Operation Guide
7.1 Display operating instructions
The ASJ display status description is shown in Table 3.
Table 3
Indicator status Line status
Steady green Voltage is normal
Red light flashes quickly (2Hz) Over pressure
Red light flashes slowly (0.5Hz) Unde rvoltage
Red light is always on Phase failure/fault
7.2 Schematic diagram of voltage action
Figure 6
Note:1.ASJ initialization time:the product is powered on after power-on or power-off, the initialization time
is 1s.
2.N is the neutral line, 1 is the live line incoming line, and 2 is the live line outgoing line. It must not
be connected wrongly.
3.Before use, please tighten the crimping screw to prevent poor contact from damaging the product.
4.This product has no short-circuit breaking capacity, and the short-circuit breaking is realized by a
circuit breaker.
Working Voltage
Contact Position

6
8Application example
8.1 Application example diagram of single-phase Self-resetting over-voltage and under-voltage protector
1)Example diagram of installation in a power distribution box on a residential level
Figure 7
Note: in the figure above is Self-resetting over-voltage and under-voltage protector.The device shall
not be installed in the household distribution box.
2)Example diagram of installation in a residential sub-compartment
Figure 8
Note:in the figure above,the lighting loop can also be designed at the rear end of the Self-resetting
over-voltage and under-voltage protector.
Self-resetting
over-voltage and
under-voltage
protector

7
8.2 Example diagram of three-phase self-resetting over-voltage and under-voltage protector
over-voltage and under-voltage protector
Figure 9
9Order example
When ordering, indicate:product model, number of poles, rated current, and quantity.
Example:Application:Single-phase line; Rated current: 63A; Quantity:100 units
Ordering model:ASJ10-GQ-1P-63 Ordering quantity:100 units
Self-resetting
over-voltage and
under-voltage
protector

8
Headquarters: Acrel Co., LTD.
Address: No.253 Yulv Road Jiading District, Shanghai,China
TEL.: 0086-21-69158338 0086-21-69156052 0086-21-59156392 0086-21-69156971
Fax: 0086-21-69158303
Web-site: www.acrel-electric.com
E-mail: [email protected]
Postcode: 201801
Manufacturer: Jiangsu Acrel Electrical Manufacturing Co., LTD.
Address: No.5 Dongmeng Road,Dongmeng industrial Park, Nanzha Street,Jiangyin City,Jiangsu
Province,China
TEL./Fax: 0086-510-86179970
Web-site: www.jsacrel.com
Postcode: 214405
E-mail: [email protected]
Table of contents
Other Acrel Protection Device manuals
Popular Protection Device manuals by other brands

Scott
Scott REACT user manual

Intermatic
Intermatic UG40 Installation instructions and operating manual

INFOSEC
INFOSEC Z3 ZenBox EX 500 user manual

Arcteq
Arcteq AQ-102LV instruction manual

Crye Precision
Crye Precision JPC SIDE PLATE POUCH SET MARITIME installation instructions

U-Line
U-Line H-4078 installation guide